Vektek Low Pressure 7MPa Catalog

Palletized Fixture Accessories

Decouplers

The First Complete Low Pressure Decoupling Solution

Automatic Shutoff Valve Decouplers for Single and Double Acting Systems n Decouplers are a complete, self contained package for disconnecting a fixture from its power supply while machining. n Everything is there for you: Quick connect coupling, filters, accumulators, pilot operated check valve and over-pressure relief valve! n Robust pilot operated check valve with 1 to 5 ratio of pilot to check pressure for proven long term reliability. n Internal 25 micron filters for added protection of pilot operated check valve thru ports A1, A2, A3, A4 & C1. Additional filtration provided at port B1. (Filtration for A3, B3 or A4, B4 available by purchasing Vektek filter block L7-0842-05 or L7-0842-06 depending on mounting orientation.) See Section K. n G1/4 ports and manifold mounting (bottom and rear) connections on all models. n Single acting pallet circuits require 2 hoses to the operating handle for pressure release.

Model No.

L5-6005-42

Pressure Range

3 - 10 MPa

Accumulator Capacity Optional In-Line Filter Cartridge

62 cm³

SAE 6 PORT PLUG INSTALLED

31,5

L7-0048-81

57,5

20,2

21,1

L7-0842-05 (Bottom A4 & B4) or L7-0842-06 (Rear A3 & B3)

Optional Filter Plate (For Manifold Mount Filtration)

I-2

B3

A3

28,6

G1/4 PORT ADAPTER. USE IN END PORT IF REQUIRED (SHIPPED LOOSE)

For use with Operating Handle Model No. L5-6008-00.

64,3

G1/4 MANIFOLD PORT

"A1" QUICK CONNECTOR CLAMP "B1" QUICK CONNECTOR UNCLAMP G1/4 MANIFOLD MOUNT PORT

B3 A3

PLUG "B" PORT FOR S/A SYSTEMS

DRILLED FOR M6 SHCS (4X)

A2 A4

B2 B4

54

MINIMUM OF 20% CLAMP PRESSURE MUST BE APPLIED TO UNCLAMP

31,8

A4

B4

B1 A1 C1

57,5

31,5

4,8

NOTE: These automatic shutoff valve decouplers and operating handle must be used with a suitable pump which includes a 4 port/3 position, P-blocked center (“A” & “B” connected to tank) directional control valve for operation of single or double acting systems. One automatic shutoff valve decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the decoupler outlet port “B” (as shown in the schematic).

108

4,8

DRILLED FOR M6 SHCS (3X)

62,3

41,4

32,9

88,9

27

30

73,3

A1

B1

C1

B2

5,6

27

77,1

4,8

57,9

44,5

63,5

SPACER - DISCARD IF BOTTOM MANIFOLD MOUNTED. FOR FILTRATION ADD 11,4 THICK FILTER PLATE

G1/4 PORT BOTH ENDS (WITH ADAPTER)

117,3

ILML56001

REV B

© Vektek January 2019

1-800-992-0236

www.vektek.com

Made with FlippingBook - professional solution for displaying marketing and sales documents online