7 MPa Valves
Sequence Valve
Sequence Cartridge Model No.
L7-0430-00
Description
Cartridge Only
Set Pressure Range 2.0 MPa (20 bar) to 6.2 MPa (62 bar) System Pressure Up to 10 MPa (100 bar)
30 5
0.101 A
30.3 0.25
0.051 A 21.39 0.1
J-5
0.051 A Minor 18.640.13
1.6
0.25 0.13
Thread M20 X 1.5 11.3 Min. 0.051 A
.002 A
3 0.13
16.5 9.28 MIN MAX
16.66 0.13
45 5
30.42 MIN TOP OF HOLE DEPTH
31.75 0.76
16.76 0.13
5.2 0.38
15.04 0.02
34.9 MIN DEPTH
30 5
Sequence Outlet
-A-
1.6
ANGLE OF INLET AND OUTLET HOLES CAN VARY AS LONG AS THE HOLE ENTERING THE CAVITY LIES BETWEEN THE MIN AND MAX DIMENSIONS SPECIFIED
5.2 0.38 Pressure Inlet
12.7 0.25
ILML70402 REV D
NOTE: For cavity tooling (multi-step Reamer and M20 x 1.5 Tap), order kit 62-7040-00. If a sequence valve is no longer needed, use 30-6011-20 plug, to cap cavity for free fluid pass through.
© Vektek February 2021
1-800-992-0236
www.vektek.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online