910141_BlueCool_VX Chillers

Marine

Technical Specifications BlueCool

VX 36M VX 48M VX 60M VX 72M VX 72M 3~

VX 120M

Cooling Capacity [BTU/h] [kW]

3,400 – 36,000 (1 – 10.5)

6,900 – 48,000 (2 – 14)

5,900 – 60,000 (1.7 – 17.6)

7,100 – 72,000 (2.1 – 21)

7,100-72,000 (2.1 -21)

10,000 - 120,000 (2.9 - 35.2)

Heating Capacity [BTU/h] [kW] (Reverse Cycle mode)

44,000 (12.9)

58,000 (17)

63,100 (18.5)

78,500 (23)

78,500 (23)

121,100 (35,5)

Dimensions (H/W/L) [mm] [Inch]

533 x 352 x 378 (21 x 13.9 x 14.9)

534 x 398 x 429 (21 x 15.7 x 16.9)

593 x 399 x 479 (23.3 x 15.7 x 18.9)

683 x 398 x 546 (26.9 x 15.7 x21.5)

698 x 401 x 546 (27.5 x 15.8 x 21.5)

771 x 401 x 638 (30.4 x 15.8 x 25.1)

Voltage/Phase

230V 1-Phase

208V 3-Phase

230 1-Phase

Frequency [Hz]

50 / 60

60

50/60

Current draw running [A]

3-13.5 (max. 15)

3-16 (max. 17)

4-18.7 (max. 21)

4-23 (max. 24)

3-16 (max. 18)

4-36 (max. 39)

Current draw ECO mode (1 – 2 – 3) [A]

10 – 7 – 4.3

11 – 8 – 5.2

13.5 – 10.9 - 7

17.8 – 11.5 – 7.8

11 - 6,8 - 5

27 - 21 - 12

Current draw Start [A]

3

3

4

4

3

4

Chilled water connection [mm][inch]

IG 25 - BSPP Female 1“

IG 32 - BSPP Female 1-1/4“

Sea water connection [l/min]

IG 19 - BSPP Female 3/4“

IG 32 - BSPP Female 1-14“

IG 25 - BSPP Female 1“

Minimum flow rate SW / CW [l/min]

40 / 33

47 / 40

55 / 50

65 / 60

65 / 60

95 / 100

Weight [kg]

49

63

76

92

94

130

Energy Efficiency (EER)

Up to 4.3

Up to 4.3

Up to 5.6

Up to 5.5

Up to 5.5

Up to 5.4

Refrigerant / GWP

R32 / 675

R410a / 2088

Optimize the BlueCool experience with accessories for the BlueCool VX-Series marine air-conditioning system. These add-ons enhance functionality, installation, and overall performance: Mounting Base: The VX-Series offers versatile mounting bases for various combinations. You can combine two or three units of different cooling capacities ranging from 36 to 120 kBTU/h, ensuring optimal fixation and stability. Pump Control Box: Installs pump relays remotely, connects to chiller units via VX-System Bus. Remote Connection Box: Monitors and controls VX-Series system remotely, includes MyTouch display, pump relays, USB interface. Master Control Box: Combines pump and remote control, pump redundancy, central power supply, emergency stop, circuit breaker.

Contact

webasto.com

Made with FlippingBook Online newsletter