Univet Cleanroom Catalogue - ENGLISH

619 autoclave sterilization, β and γ ray sterilization POLYCARBONATE Lens

92 g

GAMMA RAY radiation with 25 kGy

REFERENCE PARAMETERS

LIFE CYCLE

Lens

VLT = 87.4%

number of cycles 0 5 10 15 20 ...

Elastic Band

Δl = 60.0%

VLT= visible light trasmittance Δl = elongation%

suggested action

suggested action Replace the goggles

Change the lens

Mask elements

Number of cycles

0÷5

5÷10

10÷15

Frame

No alteration

No alteration

No alteration

Lens

VLT = 74.9% The lens becomes light yellow

VLT = 68.8% The lens becomes yellow

VLT = 62.8% The lens becomes yellow

Elastic band

Δl = 40.0% No alteration

Δl = 18.3% No alteration

Δl = 13.3% No alteration

Buckle

BETA RAY radiation with 25 kGy

LIFE CYCLE

number of cycles 0 5 10 15 20 ...

suggested action

suggested action Replace the goggles

Change the lens

Mask elements

Number of cycles

0÷5

5÷10

10÷15

Frame

No alteration

No alteration

No alteration

Lens

VLT = 82.7% The lens becomes light yellow

VLT = 68.8% The lens becomes yellow

VLT = 65.9% The lens becomes yellow

Elastic band

Δl = 46.6% No alteration

Δl = 21.6% No alteration

Δl = 16.6% No alteration

Buckle

Sterilization with STEAM 121°C for 30min in 1 ATM

LIFE CYCLE

number of cycles 0 5 10 15 20 25 30 35 40 45

suggested action

suggested action Replace the goggles

Change the lens

Mask elements

Number of cycles

0÷5

5÷10

10÷15

Frame

No alteration

No alteration

No alterationd VLT = 84.3% Δl = 42.7% No alteration

Lens

VLT = 86.2% Δl = 54.8% No alteration

VLT = 85.8% Δl = 50.2% No alteration

Elastic band

Buckle

15

Made with FlippingBook - Online magazine maker