6.4 Electrical

Prevent serious injury or death. Electrical installations must be performed by qualified electricians. Installation must conform to all national, local, and provincial codes and standards. WARNING

Complete booth assembly and then perform steps 1-5 below to connect electrical service to motor. 1. Determine voltage at your facility. RTT does not recommend using 120V single phase on motors above 1HP. 2. If a control panel or motor starter was ordered with this booth, confirm that the voltage and phase on the control panel matches the voltage and phase you intend to use. 3. Locate the wiring diagram inside the control panel that matches your voltage, phase, and HP. 4. Some motors may have 2 additional red wires. These wires are for an internal thermal overload. We do not use these wires and they should be capped off with wire nuts or electrical tape. 5. Locate the rotation arrow on the fan and verify belts are rotating in the direction of the arrow. If the belts are not rotating in the direction of the arrow, reverse the motor. 6. To insure proper wiring refer to motor nameplate for wiring diagram.