3/4 - 1.5 Hp 120V Single Phase (Wire for "Low Voltage")

3/4 - 3 Hp 230V Single Phase (Wire for "High Voltage")

To reduce the risk of electric shock, the motor is to be grounded per local electrical code.

To reduce the risk of electric shock, the motor is to be grounded per local electrical code.

T5

T1

T3

T3

T2

T5

L1 120VAC Hot

T1

T4

T4 T2

L1

Incoming 1PH power from control panel, motor starter.

T8

T8

L2 120VAC Neutral

L2

Incoming 1PH power from control panel, motor starter.

To reverse the motor Swap T5 and T8

To reverse the motor Swap T5 and T8

208 thru 240V Three Phase (Wire for "Low Voltage")

5 Hp 230V Single Phase (Wire for "High Voltage")

To reduce the risk of electric shock, the motor is to be grounded per local electrical code.

To reduce the risk of electric shock, the motor is to be grounded per local electrical code.

T1

T8

L1

T7

T1

T2

L1

L2

T4

T8

T5

Incoming 3PH power from control panel, motor starter, or VFD.

T3

Incoming 1PH power from control panel, motor starter.

L2

T5 T4 T9

T6

L3

To reverse the motor Swap T5 and T8

To reverse the motor Swap L1 and L2

440 thru 480V Three Phase (Wire for "High Voltage")

T1

L1

Incoming 3PH power from control panel, motor starter, or VFD.

T2

L2

T4 T3 T7 T5

L3

T9 T6

T8

To reduce the risk of electric shock, the motor is to be grounded per local electrical code.

To reverse the motor Swap L1 and L2