How Filtramag+ works
Secondary filtration chamber
Primary filtration takes place
Secondary filtration takes place
Outlet
(Fig 3)
(Fig 1)
(Fig 2)
Fluid then passes through an optional mesh screen which removes non-magnetic debris. The patented magnetic circuit design ensures that the filter can never block even in high contamination applications. The magnetic cores can be removed easily by hand and cleaned with the tool supplied. As an option a spare magnetic cartridge can be supplied to ensure production continuity.
With a unique “Dual Flow Technology TM ” design (Fig 1) Filtramag + is the most efficient filter of its type available. The dual flow design ensures that fluid is exposed to the high intensity magnets for the maximum time, thus ensuring almost 100% of ferrous contamination is removed on the first pass. Fluid enters through the inlet and flows up through the primary filtration chamber, (Fig 2) it then flows down through the secondary filtration chamber (Fig 3).
Technical Data
E
A
C
FM2.0+
D
B
FM1.5+
Max. flow rate
Max. operating
Dimensions mm
Magnetic Strength
Product number
pressure Connection
A
B
C
D
E
PN16 flange
litres/min
bar
gauss
FM1.5 +
250
20
1 1 /
2 "
395
255
100
180
80.5
4,000
FM2.0 +
500
20
2"
442
330
100
250
80.5
4,000
FM1.5+/11K
250
20
1 1 /
2 “
395
255
100
180
80.5
11,000
FM2.0+/11K
500
20
2”
442
330
100
250
80.5
11,000
15
Innovative Magnetic Solutions | Magnetic Filtration