Installation Options Technical Data
Application Data Selector
Technical Data
Percentage reduction required from stated maximum flow rate to obtain good filtration results.
Examples to decide what products are best for you.
Fluid Type
Material Type
Material Loading
Flow rates (ltrs/ min.)
Part No.
High speed steel
Coolant/ Wash solution
Pre-Filtration Installation - With Bypass Protect: • High pressure pump • Media filter (bags, cartridges, beds, etc) • Machine tool: through spindle components, tooling, keep sump clean, reduce wearing of part (way covers), extend coolant/oil life with no loss of physical properties.
Pre-Filtration Installation - Duplex Advantages: • Ease of cleaning • Duplex magnetic filter • Constant high efficiency filtration
Tungsten carbide
Thin oil
Medium oil
Thick oil
Mild steel
Hard steel
Stainless steel
Heavy Medium Light Wear
Cast iron
Manual
Micromag
MM5
70
0
20
n/a
n/a
0
n/a
20
n/a
n/a
n/a
n/a
n/a
n/a
✔
MM10
100
0
20
n/a
n/a
0
30
20
n/a
n/a
n/a
n/a
✔ ✔
n/a
High pressure coolant module or existing media filtration
High pressure coolant module or existing media filtration
MM20
150
0
20
30
60
0
30
20
70
n/a
n/a
n/a
✔ ✔ ✔
Filtramag+
Magnetic filter
Valves
Bypass: for cleaning
FM1.5 +
250
0
10
20
40
0
20
20
50
60
70
n/a
✔ ✔ ✔
Machine Tool
Machine Tool
Magnetic filter
FM2.0 +
500
0
10
20
40
0
20
20
50
60
70
✔ ✔ ✔ ✔
Valves
CNC Mill, Lathe, Centre or Grinder
CNC Mill, Lathe, Centre or Grinder
Automated
Machine Tool Transfer Pump
Machine Tool Sump Pump
AutoFiltrex
AF1
60
0
10
20
40
0
20
20
50
60
70
n/a
✔ ✔ ✔
Kidney Loop Filtration 24/7 Uninterrupted Cleaning
Post filtration Installation - With Bypass Coolant Polishing Protect: • Machine tool: through spindle components, tooling, extend coolant/oil life with no loss of physical properties, keep sump clean,and reduce wearing of parts (linear bearings).
AF3-RC
150
0
10
20
40
0
20
20
50
60
70
✔ ✔ ✔ ✔
AF5-RC
200
0
10
20
40
0
20
20
50
60
70
✔ ✔ ✔ ✔
Protect: • Tooling • Keep sump clean • General system cleanliness • Extend coolant life (with no loss of physical properties).
Automag Skid
AM6S1
450
0
10
20
30
0
20
20
40
50
60
✔ ✔ ✔ ✔
AM12S1
900
0
10
20
30
0
20
20
40
50
60
✔ ✔ ✔ ✔
Bypass: for cleaning
Machine Tool
Central Coolant
AM6S2
900
0
10
20
30
0
20
20
40
50
60
✔ ✔ ✔ ✔
OR
Magnetic filter
CNC Mill, Lathe, Centre or Grinder
Filter Tank, Quench Tank
AM12S2
1800
0
10
20
30
0
20
20
40
50
60
✔ ✔ ✔ ✔
Valves
AM32S1
2000
0
n/a
n/a
n/a
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
✔ ✔
Bypass
Machine Tool
Machine Tool Pump or Independent Pump i.e.. Skid / Cart
Example: Filter
Magnetic filter
CNC Mill, Lathe, Centre or Grinder
FM2.0+
Centipoise Thin oil 20 – 300 Medium oil 300 – 700 Thick oil 700+
High pressure coolant module or existing media filtration
500 ltrs/min × Medium oil (20%) = 400 ltrs/min. 400 ltrs/min × Cast iron (20%) = 320 ltrs/min. Suggested flow rate = 320 ltrs/min.
Flow
500 ltrs/min.
Material Cast iron Fluid
Medium oil
Machine Tool Transfer Pump
Valves
19
20
19
20
Eclipse Magnetics Work Smart with Magnets
Eclipse Magnetics Work Smart with Magnets
Made with FlippingBook Digital Proposal Creator