UL-Product Selection Guide

UL Product Selection Guide

Combination Fire/Smoke dampers UL HOUR RATING AMCA RATING MODEL

MAX VELOCITY (fpm)

MAX PRESSURE (in.wg)

MAX ASSEMBLY TEMP (°F)

LEAKAGE CLASS

PG

BLADE TYPE

MATERIAL

STANDARD FSD-141 FSD-142 FSD-143 FSD-151 FSD-152 FSD-151-SS FSD-152-SS

3 3 3 4 4 4 4 4 4 3 3 3 4 4 5 5 5 5 5 5 5 5 5 5 5

AIR AIR – AIR AIR AIR AIR AIR AIR AIR AIR AIR AIR AIR

1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½

1 2 3 1 2 1 2 1 2 1 2 3 1 2 1 2 3 1 2 1 2 1 2 1 2

TRIPLE-V TRIPLE-V TRIPLE-V AIRFOIL AIRFOIL

GALV GALV/SS GALV/SS

2000 2000 2000 4000 4000 2000 2000 2000 4000 2000 2000 2000 4000 4000 2000 2000 2000 4000 4000 2000 2000 2000 2000 4000 4000

4 4 4 8 8 4 4 4 4 4 4 4 8 8 4 4 4 8 8 4 4 4 4 8 8

350 350 350 350 350 350 350 250 250 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350

GALV GALV

STAINLESS AIRFOIL STAINLESS AIRFOIL

STAINLESS STAINLESS

VERT AIRFOIL VERT AIRFOIL

GALV GALV

FSD-151V FSD-152V

3 3 3 3 3 FSD-341 FSD-342 FSD-343 FSD-351 FSD-352 ACTUATOR IN THE AIRSTREAM – OUT-OF-PARTITION

TRIPLE-V TRIPLE-V TRIPLE-V AIRFOIL AIRFOIL TRIPLE-V TRIPLE-V TRIPLE-V AIRFOIL AIRFOIL TRIPLE-V TRIPLE-V TRIPLE-V TRIPLE-V AIRFOIL AIRFOIL

GALV/SS GALV/SS GALV/SS

GALV GALV

– – – – – – – – – – – – FSD-141-SP FSD-142-SP FSD-151-SP FSD-152-SP TRUE ROUND FSD-125R TUNNEL TYPE CORRIDOR CEILING FSD-141-OP FSD-142-OP FSD-143-OP FSD-151-OP FSD-152-OP FSD-171-OP FSD-172-OP SIDE PANEL – FRONT/ACCESS

1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½

GALV GALV GALV GALV GALV GALV GALV GALV GALV GALV GALV

6

1

ROUND

GALV/SS

3000

4

350

6 6 5 5

– – – –

1½* 1½* 1½* 1½*

1 2 1 2

TRIPLE-V TRIPLE-V TRIPLE-V TRIPLE-V

GALV GALV GALV GALV

2000 2000 2000 2000

4 4 4 4

350 350 350 350

FSD-171 FSD-172

FSD-171-OP FSD-172-OP

* Tunnel Type Corridor ceiling installation has 1 hr rating

Smoke dampers

MAX DYNAMIC CLOSURE VELOCITY (fpm)

UL HOUR RATING

MAX PRESSURE (in.wg)

UL555S LEAKAGE CLASS

MAX TEMP (°F)

HORIZ FLOORS

VERT WALLS

MODEL

CEILING

FIRE

PG

BLADE TYPE

MATERIAL

STANDARD SD-141 SD-142 SD-143 SD-151 SD-152 SD-151-V SD-152-V

9 9 9 9 9 9 9 9 9 9

– – – – – – – – – –

– – – – – – – – – –

TRIPLE-V TRIPLE-V TRIPLE-V AIRFOIL AIRFOIL

GALV GALV/SS GALV/SS

2000 2000 2000 4000 4000

4 4 4 8 8 4 4 4 4 4

350 350 350 350 350 250 250 350 350 250

1 2 3 1 2 1 2 1 2 1

2000 2000 2000 4000 4000 2000 4000 2000 2000 3000

GALV GALV GALV GALV

VERT AIRFOIL VERT AIRFOIL

– –

ROUND SD-151-SS SD-152-SS SD-93 TRUE ROUND SD-25R CEILING RADIATION/SMOKE

STAINLESS AIRFOIL STAINLESS AIRFOIL ALUMINUM AIRFOIL

STAINLESS STAINLESS GALV/ALUM

2000 2000 –

9

GALV/SS

3000

4

350

1

3000

9 9

CFS-171 CFS-172

3* 3*

1½ 1½

TRIPLE-V TRIPLE-V

GALV GALV

2000 2000

4 4

350 350

1 2

– –

* Tunnel Type Corridor ceiling installation has 1 hr rating

UL Product Selection Guide

Ceiling radiation damperS

UL HOUR RATING

MODEL

PG

BLADE TYPE

MATERIAL

STANDARD CFD-15 CFD-15-LP CFD-20 TRUE ROUND CFD-15R WOOD TRUSS SYSTEMS CFD-521

10 10 10

BUTTERFLY LOW PROFILE BUTTERFLY FOLDED CURTAIN

GALV GALV GALV

3 3 3

10

ROUND BUTTERFLY

GALV

3

10 10 10 10 10 10

BUTTERFLY BUTTERFLY – 90° PLENUM BUTTERFLY – R-6.3 OR 8.0 INSULATED OUTLET BOX BUTTERFLY – R-6.5 OR 8.7 INSULATED DUCT BOARD OUTLET BOX BUTTERFLY BUTTERFLY – FIELD INSTALLED 90° PLENUM

GALV GALV GALV GALV GALV GALV

1 1 1 1 1 1

1 CFD-521-90 CFD-521-BT CFD-521-IP CFD-521-NP CFD-521-NP90 COLD FORMED STEEL TRUSS SYSTEMS CFD-521-ST

10

BUTTERFLY – R-6.5 OR 8.7 INSULATED DUCT BOARD OUTLET BOX

GALV

FIRe dampers

MAX DYNAMIC CLOSURE VELOCITY (fpm)

MAX PRESSURE (in.wg)

STATIC DYNAMIC

BLADE TYPE

UL HOUR RATING

VERT WALLS

HORIZ FLOORS

MODEL

MATERIAL

CLASS

PG

STANDARD FD-140 FD-150 FD-340 FD-350 CURTAIN STYLE BLADES

11 11 11 11 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 11 11 12 12 11 11 11 12 12 12 12

DYNAMIC DYNAMIC DYNAMIC DYNAMIC

1½ 1½

– – – – A B C A B C A B C A B C A B A B – – – – – – – A B A B

TRIPLE-V AIRFOIL TRIPLE-V AIRFOIL CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN TRIPLE-V AIRFOIL CURTAIN CURTAIN

GALV/SS GALV GALV/SS GALV GALV/SS GALV/SS GALV/SS GALV/SS GALV/SS GALV/SS GALV/SS GALV/SS GALV/SS GALV/SS GALV/SS GALV/SS

4000* 4000* 4000* 4000*

4000* 4000* – 4000*

6 6*** 6 6**

3 3

STATIC STATIC STATIC

1½ 1½ 1½ 1½ 1½ 1½

– – –

– – –

– – – 4 4 4 – – – 4 4 4 – – 4 4

VFD-10-A VFD-10-B VFD-10-C VFD-10D-A VFD-10D-B VFD-10D-C VFD-30-A VFD-30-B VFD-30-C

DYNAMIC DYNAMIC DYNAMIC

4000 4000 4000

4000 4000 4000

STATIC STATIC STATIC

3 3 3 3 3 3

– – –

– – – – – – – – – –

DYNAMIC DYNAMIC DYNAMIC VFD-30D-A VFD-30D-B VFD-30D-C CURTAIN-INTEGRAL MOUNTING ANGLE

4000 4000 4000

STATIC STATIC

1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 3 1½ 1½ 1½ 1½

GALV GALV GALV GALV

– –

VFD-10-IMA VFD-10-IMB

DYNAMIC DYNAMIC

4000 4000

VFD-10D-IMA VFD-10D-IMB OUT-OF-PARTITION

DYNAMIC DYNAMIC STATIC DYNAMIC DYNAMIC STATIC STATIC

GALV/SS GALV GALV GALV GALV/SS GALV GALV

4000 4000 – 4000 2000 – –

4000 4000 – 4000 2000 – –

6 6**

FD-140-OP FD-150-OP VFD-10-OP

– 4

VFD-10D-OP TRUE ROUND

ROUND ROUND ROUND

4 – – – – 4 4

FD-125R VFD-15R VFD-35R THINLINE

STATIC STATIC

THINLINE CURTAIN THINLINE CURTAIN THINLINE CURTAIN THINLINE CURTAIN

GALV GALV GALV GALV

– –

– – – –

VFD-10-TLA VFD-10-TLB VFD-10D-TLA VFD-10D-TLB

DYNAMIC DYNAMIC

4000* 4000*

*2000 FPM on multi-section | **4 in.wg. below 8" in height | ***4 in.wg. when sizes exceed 64"×48" or 32"×96"

PBL – June 2026

Page 1 Page 2

Made with FlippingBook interactive PDF creator