Dossier Los Colibries

Living room-dining room-kitchen and bedrooms with AC5 laminated flooring. Toilets and bathrooms with porcelain stoneware. ceilings: Removable false ceiling in bathroom and/or toilet for the installation and register of the ventilation machine and pre-installation of air conditioning machine. False ceiling of laminated plasterboard throughout (except bathrooms or toilets), with a smooth plastic paint finish. Walls: The walls in the toilets and bathrooms is tiled with design stoneware material, in combination with other materials. The vertical walls are finished with smooth colored plastic paint. 08. AIR CONDITIONING AND SANITARY HOT WATER The houses will have pre-installation for air conditioning, through impulsion and return ducting in living room and bedrooms. Sanitary hot water through individual aerothermal equipment. Optional installation of a flue for the placement of a wood stove (fireplace), subject to the state/progress of the construction. 09. MECHANICS CONTROLLED VENTILATION The system of ventilation-controlled mechanics guarantees the quality of air inside, renewing stale air in homes in a continuous and controlled manner. Their functioning this based in the principle of sweeping the air inside the houses from the dry rooms (bedrooms and living room) to the wet rooms (kitchen and bathrooms). The ventilation flow adapts automatically as the needs of the occupants of each room, depending on the rate of humidity, contributing to a better level of comfort and energy saving. The benefits it has for the home are many since it guarantees a quality of indoor air, renewing constantly the environment and eliminating stale air while eliminating outside noise as it is not necessary to open the windows to ventilate. On the other hand, it avoids the inconvenience caused by uncontrolled currents and reduces the energetic cost in heating, making it easy to warm air with less humidity. The system allows a decrease in the overall ventilation flow. 10. ELECTRICITY The installation of the electrical system is done in compliance with regulation B.T. Electrotechnical unit, with sufficient power, depending on each dwelling, to satisfy the power of the electrical appliances included.

Technical specifications SEMIDETACHED VILLAS

01. FLAT Roof usable as a terrace-solarium. Formed with a double layer of waterproofing and, on top of it, a layer of thermal insulation and finished in ceramic flooring suitable for exteriors. Tower leading out onto the terrace with a flat roof finished in ceramic flooring. 02. FACADE The exterior facades are made of ceramic brick with a thermal insulation system on the outside and finished with an acrylic coating. The interior face with laminated plasterboard. The system of thermal insulation on the outside is based in the covering of the façade with insulator plates, creating an envelope that slows the loss of heat in winter and the entrance of heat in summer, optimizing energy savings in heating and air conditioning. The reduction in the use of energy directly reduces CO2 emissions into the atmosphere, the optimal thermal performance of the living place provides a comfortable and healthy environment. 03. TERRACES The terraces will be tiled with stoneware suitable for exteriors. Equipped with security glass railings, combined with areas of blind brick masonry. 04. EXTERIOR CARPENTRY The exterior carpentry is made up of a PVC profile with opening according to the project. Blinds in living room and bedrooms in aluminium with insulation and finished in the color of the carpentry. The glass windows are double-glazed with an intermediate chamber of “low emission” type. The main advantage of Low Emissive glass is the improvement of the energy efficiency of the windows, reducing the heating and air conditioning bill. They minimize heat loss from the home because they reflect part of the energy emitted by the system of heating and it’s

returned to the indoor environment. On the other hand, they have extraordinary properties for the transition of natural light, contributing to energy saving and the use of day light. In the months of winter the glasses low emission reduce heat loss and in summer, in homes with orientation south minimizes the effect of transmission of heat to the inside, It is complemented by a solar factor control sheet that reflects part of the energy. 05. CARPENTRY INSIDE The main entrance door to the living room it is armored, with inside finish equal to the rest of doors. The interior doors have a lacquered finish. All doors step have 35 mm. of thickness with hinge and hardware of steel. Modular wardrobes and open walk-in wardrobes without doors, depending on the type of home, totally dressed in its inside with shelves, hanging bars and chest of drawers 06. DISTRIBUTION INSIDE The interior partitioning between the different rooms of the house is made of laminated plasterboard on a structure of steel intermediate in both faces and inner thermal-acoustic insulation. The separations between the dwellings are formed by perforated brick clad on both sides, by means of a plasterboard on steel frame and thermal-acoustic insulation inside. The constructive system used is eco-efficient and sustainable. The protection of the faces of the plasterboard laminated with the multi-ply cellulose sheet, confers superior resistance to that of traditional plaster trim and plastering. The plasterboard is hygroscopic and acts as a “third skin” against humidity, absorbing it when the ambient is excessively moist and expelling it when it is dry.

07. INTERIORS Floors:

22

Made with FlippingBook - professional solution for displaying marketing and sales documents online