Liberty Weld Cell User & Maintenance Manual

6) Extinguish

The suppression agent will contain and possibly extinguish a fire. However, due to the volatility of

materials trapped in the filters, they may reignite. It is recommended that Safety Personnel using personal

protective equipment immediately shut down main power to the unit and remove the filters from the plant

environment. Once the suppression agent generator has been activated, power can be turned off. When

the Suppression agent is triggered, the fire bottle indicator will light up. It can be cleared by pressing the

FSS Reset button.

NOTE:

Opening the door will allow the fire suppressing agent to escape from the

unit and allow additional oxygen to enter the system.

6) Inspect

The suppression agent leaves a dust layer. The filters can then be inspected for damage and further

extinguished as required. Some or all filters will most likely need to be replaced. Please inspect your unit

for possible damage before reinstalling undamaged filters.

7) Restart

Turn the key switch to the off position to temporarily deactivate the FSS to prevent initial false alarms due

to contamination beyond the filters. Turn on the main power and cycle the unit power disconnect from off

to on. This will reset the system. Check to be sure the unit’s smoke detectors are showing green fla shing

lights. Run the unit for a short period of time to purge any residual smoke. Clean the smoke detector with

compressed air if required. Once the unit has been cleaned, the key switch can be turned to the on

position to reactivate the FSS and allow proper detection. This may take several cleanings.

8) Reset

The Fire Suppression Screen can be reset by power cycling the unit. The “FB Released” notification can

be reset by holding A and B, and press OK. It is recommended to reset the “FB Released” notifica tion on

the display after replacing the Fire Bottle.

9) Install the Replacement Generator

In the filter compartment, disconnect the suppression agent generator and remove it from its mount.

Install the new generator in its place and re-terminate the control wiring on the new generator. Clear

the “FB Released” notification by holding A and B, and press OK.