Fluke Australia 2020 Test Tools Catalogue

Fluke 715, 707, 707Ex and 705 Loop Calibrators Complete family of Volt/mA calibrators

Specialty Models

Fluke 715 Volt/mA Calibrator • Source voltage to 200 mV or 20 V • Measure loop current (0 to 20 mA, 4-20 mA) signals with 0.01 % accuracy and 1 µA resolution • Measure voltage output process signals from PLCs, transmitters • Source or simulate 4-20 mA loop current • 24 V loop supply with simultaneous current measurement • Ramp and Step Ramp output functions • Innovative output adjustment dial on 707 provides 1 µA and 100 µA resolution and one-hand operation • Large display and simple interface for ease of use • Simultaneous mA and % readout for quick, easy interpretation of readings • HART™ mode on 707 connects 250 ohm resistor in series with 24 V loop for compatibility with HART communicators • Push button 25 % steps for fast, easy linearity checks • “Span Check” for fast confirmation of zero and span • Selectable slow and fast linear step ramp provide ramping outputs for valve slewing, remote testing and loop functional tests • 24 V internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM • 0 to 20 mA or 4-20 mA default start up modes • Three year warranty • Three year warranty Fluke 707 and 705 • mA accuracy of 0.015 % on the Fluke 707 and 0.02 % on the 705

Fluke 707Ex Intrinsically Safe Loop Calibrator The fast one- handed tool for mA loop checks in Ex zones. The 707Ex is an

intrinsically safe loop calibrator for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2. • Simultaneous mA and % readout for quick, easy, interpretation of readings. • mA accuracy of 0.015%, superior to other loop calibrators See page 134 for more information.

Fluke 715

Fluke 705

Recommended Accessories

TL28A Heavy Duty Test Lead Set See page 156

TL220

SureGrip™ Industrial

Test Lead Set See page 144

Fluke 707

C550 Tool Bag

PV350

705/707

715

Pressure Vacuum Module See page 155

See page 153

Voltage measurement Range

0 V to 28 V

0 mV to 200 mV / 0 V to 25 V

Resolution Accuracy

1 mV

10 µV / 1 mV

705: 0.025 % Rdg + 1 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD

0.01 % Rdg + 2 LSD

Included Accessories Fluke 705/707: C10 Yellow Holster, Test Leads, AC175 Alligator Clips, Single 9V Alkaline Battery, Instruction Sheet. Fluke 707Ex: Red Ex-holster, Test Leads, AC175 Alligator Clips, Single 9V Alkaline Battery, Instruction Sheet. Ordering Information Fluke 715: Yellow Holster (H80M excl. TPAK), Test Leads and AC175 Alligator Clips, Single 9V Alkaline Battery, Instruction Sheet.

Current measurement Range

0 mA to 24 mA

0 mA to 24 mA

Resolution Accuracy

0.001 mA

0.001 mA

705: 0.02 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD

0.01 % + 2 LSD

Current sourcing Range

0 mA to 20 mA or 4 mA to 20 mA 0 mA to 20 mA or 4 mA to 20 mA

Accuracy

705: 0.025 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD

0.01 % Rdg + 2 LSD

Drive capability

705: 1000 Ω @ 24 mA 707: 1200 Ω @ 24 mA 707Ex: 700 Ω @ 20 mA

1000 Ω @ 24 mA

Loop power while measuring mA Voltage sourcing

24 V

0 mV to 200 mV or 0 V to 20 V

FLUKE-707 FLUKE-705

Loop Calibrator Loop Calibrator

Display current and % of span Auto step, auto ramp

Yes

mA or %

Yes Yes

FLUKE-707EX

Volt/mA Calibrator Intrinsically Safe Loop Calibrator

Span Check Battery life

18 hours typical, at 12 mA

FLUKE-715

C ontact your local distributor for price and availability. www.fluke.com/au/wtb

www.fluke.com/au/PCT

Process Calibration Tools

107

Made with FlippingBook Learn more on our blog