PRODUCT CATALOGUE 2022 | alre.de

Electronic floor temperature controller with remote sensor (for floor heating/wall and ceiling heating) FETR Flush-mounted installation – Design Berlin UP

Technical data

Application

Design:

Berlin UP (flush-mounted)

Temperature control (e.g., of electrical heating systems) for floor, fringe zone, bathroom, ceiling, tiled stove, marble and wall heating systems or tempering systems, direct floor heating systems. Reduction: With these flush-mounted controllers, the temperature can be reduced by 5 K. For this purpose, potential is applied to the clock input terminal by an external pilot controller or an external timer L1. Note: The sensor line must be routed in a protective duct. Parallel routing together with lines that carry alternat- ing currents is not admissible. The 55 x 55-mm variants visually fit perfectly without an insert frame in many switch ranges of 55 x 55 mm. Using an insert frame, the 50 x 50- mm variants fit in almost all switch ranges. See page 86 for an overview of currently possible combinations and insert frames.

Housing material: Operating voltage:

PC plastic

230 VAC, 50 Hz −20 … +70 °C

Storage temperature: Permissible atmospheric humidity: Electrical connection: Mounting/attachment:

Max. 95% rel. humidity, non-con- densing

screw-type terminals

In flush-mounted socket (deep flush-mounted socket recommend- ed), can be adapted with 50 x 50 mm or 55 x 55 mm cover set to fit virtually any switch range

Protection rating: Protection class: Safety and EMC:

IP 30

II, if properly mounted

according to DIN EN 60730

Max. switching voltage: Min. switching voltage:

230 VAC, 50 Hz 230 VAC, 50 Hz

Switching element: Switching contact:

relay

NO contact

Output signal:

switching (230 VAC, 50 Hz)

Sensor:

external or internal/external (monitors)

Sensor type (external): Sensor rupture and short-circuit protection: Sensor wire extendable up to:

HF-8 / 4-K2

heating is switched off

50 m with min. 0.5 mm² double- insulated

Control function:

heating

Hysteresis:

< 1 K

General features:

ECO function; “reduction” display; “heating” display approx. 5 K (230 VAC, 50 Hz)

Input “temperature reduc- tion”:

Type/image

Item no.

Features

Circuit diagram

PG

FETR 101.700#07

General features: Floor temperature controllers; internal setting; multi-digit display 1 … 6 Ambient temperature: 0 … 40 °C Max. switching current: 16 (2) A Switching power: 3680 W Control range: 10 … 60 °C Scope of delivery: controller, remote sensor 4 m, cover 50 x 50 mm, pure white (like RAL 9010), glossy General features: Floor temperature controller; mechan- ical range limitation; “on/off” switch; external setting; protective cap; contact hazard protection cover plate; multi-digit display 1 … 5

UN030000

I

FETR 101.715#00

UA030119

I

Ambient temperature: 0 … 40 °C Max. switching current: 16 (2) A

Switching power: 3680 W Control range: 10 … 50 °C Scope of delivery: controller, remote sensor 4 m Cover sets are offered in various designs (see the separate overview, “alre flush-mounted range (cover sets)”) and are not included in the delivery. Suitable set no: JZ-005.xxx, for example: cover set 50 x 50 mm, pure white, glossy: JZ-005.000 cover set 55 x 55 mm, pure white, glossy: JZ-005.100

Catalogue 2022 | Page 102