C40-2x 0-10V / 6PNP Axial coupler
Inductive Coupling System
■ Contact free transmission of energy and signals ■ Ideal for gripper changing systems and pallet change applications ■ Integrated IO-Link sensor hub
G
A
B D
2 x M4
Base
Status LED`s
Remote
G
Base
Remote
2 x M4
2
2
3
3
4
4
10
10
11
11
1
1
5
5
12
12
9
9
6
6
8
8 7
7
Male connector 12-pin M 12 x 1
Female connector 12-pin M 12 x 1
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system C40-2x 0-10V / 6PNP
Base
Remote
Type Id. No.
0E012720
0E012721
A B C D
mm mm mm mm mm mm mm
45 40 22 32 11
E F
9.5
G
13
10.6
Housing material Protection class Operating temperature
AL IP67
-25° C ... +50° C -25° C ... +80° C 0 - 3 mm
Storage temperature Transmission distance Weight Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple Reverse polarity protection Temperature monitoring Data-Valid Output Ready delay Ready for operation (switching on the entire system) Ready for operation (approach remote to switched-on base) Delay on signal change (analog signal / digital signal) PIN assignment
kg
0,087
0,086
24 V (18 ... 30 V)
-
-
24 V ± 10% DC
2000 mA
-
-
625 mA
-
< 200 mV
-
150 mA
-
< 600 ms < 1200 ms < 600 ms < 20 ms / <10 ms
Signal Base
Signal Remote
Supply voltage Ground
1 2 3 4 5 6 7 8 9
24 V IN
24 V OUT
GND
GND
Digital signal 1 Digital signal 2 Digital signal 3 Digital signal 4 Digital signal 5 Digital signal 6 Analog signal 1 Analog signal 2 Ground Analog signal Data-Valid
0/24 V OUT 0/24 V OUT 0/24 V OUT 0/24 V OUT 0/24 V OUT 0/24 V OUT
0/24 V IN 0/24 V IN 0/24 V IN 0/24 V IN 0/24 V IN 0/24 V IN
0 ... 10 V OUT 0 ... 10 V OUT Analog GND *
0 ... 10 V IN 0 ... 10 V IN
10 11 12
Analog GND *
DAV 24 V
-
* For analog operation, analog GND and GND must be connected externally.