Confidentiality Notice: This electronic message contains information from ElQuator Sdn Bhd which may be privileged or confidential. The information is intended to be for the use of the individual(s) or entity named above. If you are not the intended recipient be aware that any disclosure, copying, distribution or use of the contents of this information is prohibited. If you have received this electronic message in error, please notify us by telephone or email (to the numbers or address above) immediately.
SHOWTHEWORLD IT CAN BE DONE
In future, the Asian market and the world will look upon our system with admiration. We take great pride in the fact that our system can deliver all this with zero CO2 emission commitments whilst creating a cutting-edge, stable infrastructure for supplying more electricity production for the people with NO taxpayer’s money being spent anywhere anytime. Furthermore, our system utilizes a collection of rainwater and condensation water as supply source to our storage area; it cleans the water to drinking standard and delivers clean water directly to our consumer.
It all comes down to one thing and one thing only – to help other people.
ANYBODY CANAGREE TO ENJOY CHEAPER TARIFF – WITH NOCOST It is not that difficult to set up a system that can produce clean energy. However the scale of it can be a huge challenge. The difficult part is to make it stable and to make it profitable. Reducing cost is a no-regrets move in an industry facing slow growth, rising cost and heightened competition. ElQuator offers a progressive solution that is easily integrated into existing architecture. It simplifies the procurement process for energy storage with full planning and deployment and fully managed construction in sustainable ways as follows: ü Security: Delivering the highest level of reliability and availability of electricity to end– users in all areas/part of the world (all system run on a storage concepts, nonstop – get the power you need when you need it) ü Environment: CO2 free, clean energy from existing resources. NO need for nuclear power or construction of new Hydro dams ü Economy: Cost effective energy. Under this model, there is essentially NO cost to the Government/Grid System Operators and Regulators (installation costs will be borne by the Group Founders/Stakeholders) ü Industry: Focus on specific market and contract requirements, guaranteeing performance on unique market and operating constraints as well as improving domestic infrastructures
FOCUS ON MONEY IN A TWO-WAY STREET
To generate & supply sustainable electricity (SEP)* To treat & supply cleanwater consumption (UWS)* To set up a waste managementsystem To develop&manage the projectfrom initial feasibility studies, projectbudgeting, masterplanning, fund sourcing, construction& ultimatelyopening& operation To providemaintenance & services To ensure 98% manpowerwill be recruited locally To allocate 8% of our gross income to CSR: education/scholarship green infrastructures/initiatives * SEP – Sustainable Energy Plant UWS – UndergroundWaterSystem
To identifyasuitable location fordevelopment To provide 30 acres of land (lease orsell) To provide IPP licensed capacity/permits To pay electricity consumed basedon agreed prices/rates set by TNB/Energy Regulator To establish a long termcontract on energy supply, land acquisition&necessary licenses To provide access to local universities/schools/local institutions fortechnology transfer To identify&source local talent supply To establish aframe work formonitoring utilization of trust fund& CSR initiatives
29
powering the world
POWERINGDENMARK
Hydro Plant • Hydro 30 years license for Denmark is DKK 50,000,000.00 • With the license rights, the licensee can set up any numbers of the hydro plant with two ways: • Licensee pay DKK 3,283,144.00 for rights to system specifications, drawing, electrical installation, Pelton turbine, and Pryter Impeller and set up the system according to ElQuator’s design or • Licensee can buy a complete system with the price of DKK 11,150,870.02 per one MWh • Royalty for every kilowatt-hour is DKK 0.12. The price includes service and maintenance and insurance • Electricity sold (estimated) at the price of DKK 0.2967 per kilowatt-hour • Selling power sample calculation for 1000MW: 1000MW x 24 hours a day = 24,000,000 kilowatt-hour a day 24,000,000 x 30 days a month = 720,000,000 kilowatt-hour a month 720,000,000 x DKK 0.2967 = DKK 213,624,000.00 a month • Service and maintenance and royalty paid to licensor: 720,000,000 kilowatt-hour x DKK 0.12 = DKK 86,400,000.00 a month • Licensee’s net profit: DKK 213,624,000.00 - DKK 86,400,000.00 = DKK 127,224,000.00 a month • System’s cost for 1000MW: 1000 plant x DKK 11,150,870.02 = DKK 11,150,870,020.00
POWERINGDENMARK
EV Charger • EV Charger 30 years license for Denmark is DKK 8,000,000.00 • Royalty for every kilowatt-hour is DKK 0.12. The price includes service and maintenance and insurance • The cost to set up charging post system is DKK 454,715.44 per system • Charging price is approximately DKK 2.29 per kilowatt-hour • Sample calculation for 500 charging post assuming using Nissan Leaf with 30kWh battery: One Nissan Leaf charge 30 kilowatt-hour per time x DKK 2.29 per kilowatt-hour = DKK 68.70 per car per charge DKK 68.70 x 500 charging post = DKK 34,350.00 per day per charge DKK 34,350.00 per day per charge x 30 days a month = DKK 1,030.500.00 per month • Service and maintenance and royalty paid to licensor: 30 kilowatt-hour per car per charge x DKK 0.12 per kilowatt-hour x 500 charging post x 30 days a month = DKK 54,000 per month
• Licensee’s net profit:
DKK 1,030,500.00 – DKK54,000.00 = DKK 97,500.00
• System’s cost for 500 charging post: DKK 454,715.44 x 500 = DKK 227,357,720.00
POWERING INDIAAND SAARC COUNTRIES
• Total of 2500MWh planned for India and SAARC countries • Power sold at INR 4.15 per kilowatt-hour • Approximate power sold to India and SAARC countries according to the calculation below: 2500 MW x 24 hour a day = 60,000,000 kilowatt-hour a day 60,000,000 x 30 days a month = 1,800,000,000 kilowatt-hour a month 1,800,000,000 x INR 4.15 = INR 7,470,000,000.00 a month INR 7,470,000,000.00 = DKK 704,110,298.80 a month
• Service and maintenance calculation: 1,800,000,000 x DKK 0.12 = DKK 216,000.000.00
• Net profit from 2500MW:
DKK 704,110,298.80 - DKK 216,000.000.00 = DKK 488,110,298.80
• System’s cost for 2500MW:
2500 MW x DKK 11,150,870.02 = DKK 27,877,175,050.00
S U S T A I N A B L E E N E R G Y P L A N T
The Sustainable Energy Plant is an interdisciplinary initiative of the ElQuator Group to solve a pressing need for electricity and water ʹ delivering the most reliable, safe and best performing storage solution for the utility industry. This technology is a vital step in reducing the impact of climate change and providing a more secure future for the environment, public health and the wellbeing of the future generations
100% CO 2 FREE SUN + WATER + WIND = SUSTAINABLE ENERGY
NO NUCLEAR PLANT NO NEW HYDRO DAMS
The SEP can deliver up to 3.0MW per hour per line. Each system contains 16 lines + backup units. On 24 hour basis, the plant deliver 1.4GW per day per system. More than one system can be established per area if required
2
Our virtual designs shows how the future supply of water & electricity can be like
We take great pride in the fact that our system can deliver all this with zero CO 2 emission commitments whilst creating a cutting- edge, stable infrastructure for supplying more electricity production for the people with NO ƚĂdžƉĂLJĞƌ͛Ɛ money being spent anywhere anytime. Furthermore, our system utilizes a collection of rainwater and condensation water as supply source to our storage area; it cleans the water to drinking standard and delivers clean water directly to our consumer. It all comes down to one thing and one thing only ʹ to help other people.
S U S T A I N A B L E E N E R G Y P L A N H O W D O E S T H E S Y S T E M W O R K S
1 st System VERTICAL WINDMILL
2 nd System AR18
5 th System HYDRAULIC
3 rd System O8
4 th System H 2 O
We have five (5) independent systems that work separately and supporting each other; therefore NO system is running on maximum capacity. In the event of any failure, the other systems will automatically increase their power production. The whole system operates as an integrated unit, not as separated components.
5
SUSTAINABLE ENERGY PLANT Hydro dams are widely used and extremely effective and their success is well documented. But in this system, we use our own energy to recycle the water, the spinning shafts move the water back to its own reservoir. By using a siphoning principle, power is generated twice in the process. Our hydro system is 100% dependable and relatively small. One MWh system only requires 1000m2 of land area. Advantages of Sustainable Energy Plant: ü Able to produce any amount of megawatt power of electricity per hour ü Not utilizing big area of land and not jeopardizing surrounding ecosystem ü Does not require continuous cost to produce electricity ü Can easily connected to the grid or micro-grid for localize power distribution
MICRO-HYDRO SYSTEM
Micro Hydro System is also known as a stand-alone hydro system. The unit can stand on its own and able to produce any amount of energy as it designed for, but it is not wise to run any system on 100% full performance. It will only be run on 75% performance 24 hours a day but will be put full 100% performance when needed. The Micro Hydro System is simple as described in Wikipedia as pump hydro. There is mathematics in this that needs to be abided. Power in and power out minus lost in transmission is the well-known factor. Also, to use small power to gain larger power. To make it simple in this resume, we use from 22% to 28% of the total power produced to have the 100% outcome from the main generator. We drop the water from a minimum height of 15 meters and at an angle of 32 degrees. The water run along a pipe size dimensioned to the specifications for the outcome. The pipes have small impellers along with it to produce DC power to storage. When the water hits the main Pelton turbine, the turbine will rotate. The rotations go to the generator that produces AC power into either a synchronizer or controller, transformer and then to the grid. The synchronizer or controller use to make sure the HZ, AMP, and voltage are the required specifications. The water reaches in the upper reservoir after leaving the main turbine Pelton. From here it will be guided to the 4 + 2 meter Kaplan gate system, before sending it back to the reservoir at 15 meters up. The Kaplan gate system is only for the power to return to the pump systems. It is when 22% to 28% of the power produced is used back to push the water back into the reservoir for the next cycle. It also acts as the backup system when needed if there is a break down to the system. Micro Hydro system, on the other hand, has a lot of components. The main parts of the system are the AC generators and AC pumps, metal pipes in a various dimension and length; Pelton, Francis and Kaplan Turbine are all known in the hydro system. Size of the pipes matches the head and water speed. Control unit is custom made depends to project. H beam and ankle iron are 80% of the system's structure.
• Below is the calculation to represent the 1MW power requires. It shows 1.3MW produced whereby 22% to 28% is used for the pumps to function in pumping the water back to the top reservoirs.
Micro Hydro System Calculation
Total output
kW
1,300
Water consumption Water consumption
l/sMW l/hMW
529
1,904,400 2,475,720
Total water consumption
l/h
Calculation of Pipe Cross Section
D Q
1.25dm
27 l/s
q
1.23dm2
v
2.17m/s <3m/s
MICRO-HYDRO SYSTEM
POWER PRODUCED CALCULATION
P = η ∙ ρ ∙ Q ∙ g h, where • P is the power in watts • η is the turbine efficiency coefficient (dimensionless) • ρ is the water density in kg / m3 • Q is the flow in m3 / s • g is the acceleration of gravity • h is the difference in height between inlet and outlet https://en.wikipedia.org/wiki/Hydropower Flow in a Tube (Manning) • Q = 1 / n ∙ ∙ A (r / 2) ^ (2/3) ∙ √S • Q = Water flow - m³ / s • A = The cross-sectional area - m² • n is coefficient of friction (eg 0.009 for plastic) • S slope of the pipe Q = 1 / n ∙ A ∙ (r / 2) ^ (2/3) ∙ √S With plastic pipes and a pipe diameter of 20 cm = 0.02 meters Area of pipe "A" = πr² = π (0.1 meter) ² S = 35ᵒ / 90ᵒ
Q = 1 / n ∙ ∙ A (r / 2) ^ (2/3) ∙ √S = 1 / 0.009 x π (0.1x0.1) x (0.1 / 2) ^ (1/3) x √ (35/90) = 1 / 0.009 x π (0.1x0.1) x (0.0025) ((1/3) x √0.38 = 1 / 0.009 x π (0.01) x (2.5) ((1/3) / 10 x0.615 = 1 / 0.009 x π 0.01 x 1.36 / 10 x 0.6 = 0, 3 m³ / s
STAND-ALONE MICRO-HYDRO SYSTEM
CROSS SECTIONMICRO-HYDRO SYSTEM
CROSS SECTIONMICRO-HYDRO SYSTEM
CROSS SECTIONMICRO-HYDRO SYSTEM
____________________________ MAIN EQUIPMENTS IN MICRO HYDRO SYSTEM
PUMP – DAB K20/1200 T
PUMP - DAB K20/1200 T
PUMP - DAB K20/1200 T
PUMP - DAB K20/1200 T
GENERATOR - FLD444D
GENERATOR - FLD444D
GENERATOR - FLD444D
COMPRESSEDAIR SYSTEM
To have pure Renewable Energy for the EV Charger, we used Compressed Air System to generate and supply the power to our charging post. Our system will compress the air into a smaller size using 300 bars pressure. We take the atmospheric air and then physically force it into a smaller volume, the molecules take up less space and the air is compressed. We compressed all types of air such as Nitrogen, Carbon Dioxide & other gases which the “ingredients” in the air will not change when it’s compressed. Compressed Air System is a new way to produce electricity. When the molecules are compressed in a smaller space, they don’t necessarily want to be, and they will spread apart as quickly as possible the first second they can. That’s what causes pressure. Atmospheric air has one bar of pressure but can be forced up to over 300 PSI of pressure when compressed into a smaller state. Once the air is released, the pressure will spin the turbines and generators to produce power. Exactly how pressurized compressed air becomes is determined by science. Three scientific laws explained how compressed air works. Collectively, three laws explain that pressure, volume, and temperature are proportional. The way we produced energy is evolving. By having the Compressed Air System in our EV Charger, charging the car will be as fast as we never imagined before. Compressed Air System able to produces green, renewable and sustainable energy. By having it in the EV Charger, we could justify saving the CO2 index will be lowered as well as promising that the electric car is green. The world can continue the progress to having more electric vehicles on the roads and charged with the pure source of Renewable Energy.
COMPRESSEDAIR SYSTEM
COMPRESSEDAIR SYSTEM
COMPRESSEDAIR SYSTEM
____________________________ MAIN EQUIPMENTS IN MICRO HYDRO SYSTEM
CORPORATE SOCIAL RESPONSIBILITY
“A good company offers excellent products and services. A great company also offers excellent products and services but also strives to make the world a better place.” - Philip Kotler.
We’re giving back 4% of our gross profit to the local communities as part of our Corporate Social Responsibility (CSR).
We believe that corporate responsibility is a virtuous cycle, where our support helps to build and grow sustainable environments in which everyone prospers.
ADVANTAGESWITH OUR SYSTEM
ü Efficient source of energy ü Green, sustainable and renewable energy ü The power created 24/7, 365 days a year, rain or shine ü Not jeopardizing the natural environment and surrounding area ü Cost-effective and easy to install ü Low-cost maintenance ü No continuous cost for as long as the system runs ü Generates pure green energy that are pollutants free for the environment ü Can reduce carbon footprint in the long run
PRODUCEAND DISPOSE PLAN
“You cannot get through a single day without having an impact on the world around you. What you do makes a difference, and you have to decide what kind of difference you want to make.” - Jane Goodall As we fight to produce clean energy, we are taking things seriously for the future. We stress on using environmentally friendly raw materials for all our system. And to set up our micro-hydro system in a green manner. We use raw materials such as aluminium and iron can be recycled after 100 years used. So as much as we want to build, we will surely not contribute more to endangering our world.
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43Made with FlippingBook - professional solution for displaying marketing and sales documents online