CAPABILITY STATEMENT: ARCAERO
CAPABILITY STATEMENT: ARCAERO
PAGE 8
PAGE 9
With the World Athletics Championships taking place in Budapest in 2023, a brand-new stadium was constructed on the banks of the Danube, initially with a capacity of 36,000 for the games, reducing to 14,000 for its post-games life. ArcAero initially became involved in the project to provide external advice to the design team about initial wind tunnel tests that had already been carried out. Later, we were asked to carry out further studies to look at the wind loading for both the Games and Legacy configurations of the stadium. Further still, we were asked to consider three construction scenarios with ¼, ½ and ¾ of the roof constructed in turn. In terms of deliverables, we were asked to produce, per configuration, worst- case wind loading patterns that corresponded to particular load cases of interest, plus, peak worst-case pressures for use in the design of the tensile roof membrane. Stadia are always challenging, often for different reasons. A major challenge for this stadium was the the very open nature, where the roof seems to almost float in mid-air, supported only by slender structural columns. NATIONAL ATHLETICS CENTRE BUDAPEST CASE STUDIES
To measure pressure at hundreds of roof taps, typically requires tubing to carry the signal to the instrumentation beneath the wind tunnel. Significant numbers of tubes like this would risk destroying the true aerodynamic behaviour the modelling seeks to capture, and compromise the fidelity of the measurements. As with other structures of this nature, our ‘invisible instrumentation’ technique came to the fore. Hundreds of hidden pathways were routed through 3D printed components of the stadium, each housing the main roof surface, primary and secondary structure, including gantries and other ancillary structures. This ensured that we could produce the best possible replica of the architecture without compromising resolution, modelling fidelity or accuracy. With rigorous model design, and digital & physical construction, both via 3D printing and conventional techniques, we made certain that the right wind tunnel model was produced, with instrumentation positions optimised to provide roof-wide loading information, worst-case point measurements, and densely instrumented super-bays to provide the resolution required for roof membrane design and temporary construction scenarios, where different bays were more significantly exposed for a short period of time.
Services provided:
• Structural wind loading study • Roof membrane loading study
Made with FlippingBook - Online magazine maker