FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

8431 Murphy Drive Middleton, WI 53562

Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building

TEST REPORT FOR HY-C COMPANY, LLC Report No.: 104415176MID-002AR2 Date: 11/09/21

RUN #4 (9/19/20): The furnace was set to draw a category 3 output rate. The test load weighed 32.35 lb. and utilized a 7.0 lb. coal bed. The average Btu/hr. output was 24,739. Burn time was 3.73 hours. The kg/hr. burn rate was 3.19. TABLE 1 – DATA SUMMARY PART A Θ W fuel MC ave Q in

Q out

Wood Weight as- fired

Run No.

Load % Capacity <35% of Max 36-53% of Max 53-76% of Max Max capacity

Target Load Btu/hr 16,252

Actual Load Btu/hr 15,727

Actual Load

Test Duration

Wood Moisture

Heat Input

Heat Output

Cat

% of Max

hrs

lb

% DB 21.97

Btu

Btu

I

3

33.87

6.57

37.19

262,070

103,277

2

2

24,610

21,540

46.39

5.82

35.58

19.92

255,004

125,290

3

4

34,826

24,739

53.28

3.73

32.35

21.55

225,737

92,358

4

1

46,435

46,435

100.00

2.93

30.61

20.27

218,757

136,210

TABLE 2. – DATA SUMMARY PART B E T E

E

E

E

E g/hr

 del

 SLM

PM Output Based

Load % Capacity

Total PM Emissions

PM Output Based lb/mmBtu Out

1 st Hour Emissions

1 st Hour Emissions Lb/mmBtu Out

Delivered Efficiency

Stack Loss Efficiency

Category

Run No.

PM Rate

g

g/hr 1.36

g/MJ 0.06

g/hr 1.04

%

%

<35% of Max 36-53% of Max 53-76% of Max Max capacity

I

3

6.80

0.15

0.099

39.4

69.6

2

2

8.10

0.14

2.69

0.134

0.06

1.39

49.1

70.1

3

4

4.12

0.10

2.58

0.169

0.04

1.10

40.4

69.0

4

1

6.73

0.11

1.35

0.042

0.05

2.30

62.3

67.0

Version: 03/13/18

Page 16 of 25

RT-L-AMER-Test-3778

Made with FlippingBook - professional solution for displaying marketing and sales documents online