TEST REPORT FOR HY-C COMPANY, LLC Report No.: 104415176MID-002AR2 Date: 11/09/21
RUN #4 (9/19/20): The furnace was set to draw a category 3 output rate. The test load weighed 32.35 lb. and utilized a 7.0 lb. coal bed. The average Btu/hr. output was 24,739. Burn time was 3.73 hours. The kg/hr. burn rate was 3.19. TABLE 1 – DATA SUMMARY PART A Θ W fuel MC ave Q in
Q out
Wood Weight as- fired
Run No.
Load % Capacity <35% of Max 36-53% of Max 53-76% of Max Max capacity
Target Load Btu/hr 16,252
Actual Load Btu/hr 15,727
Actual Load
Test Duration
Wood Moisture
Heat Input
Heat Output
Cat
% of Max
hrs
lb
% DB 21.97
Btu
Btu
I
3
33.87
6.57
37.19
262,070
103,277
2
2
24,610
21,540
46.39
5.82
35.58
19.92
255,004
125,290
3
4
34,826
24,739
53.28
3.73
32.35
21.55
225,737
92,358
4
1
46,435
46,435
100.00
2.93
30.61
20.27
218,757
136,210
TABLE 2. – DATA SUMMARY PART B E T E
E
E
E
E g/hr
del
SLM
PM Output Based
Load % Capacity
Total PM Emissions
PM Output Based lb/mmBtu Out
1 st Hour Emissions
1 st Hour Emissions Lb/mmBtu Out
Delivered Efficiency
Stack Loss Efficiency
Category
Run No.
PM Rate
g
g/hr 1.36
g/MJ 0.06
g/hr 1.04
%
%
<35% of Max 36-53% of Max 53-76% of Max Max capacity
I
3
6.80
0.15
0.099
39.4
69.6
2
2
8.10
0.14
2.69
0.134
0.06
1.39
49.1
70.1
3
4
4.12
0.10
2.58
0.169
0.04
1.10
40.4
69.0
4
1
6.73
0.11
1.35
0.042
0.05
2.30
62.3
67.0
Version: 03/13/18
Page 16 of 25
RT-L-AMER-Test-3778