FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

8431 Murphy Drive Middleton, WI 53562

Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building

TEST REPORT FOR HY-C COMPANY, LLC Report No.: 104415176MID-002AR2 Date: 11/09/21

TABLE 3 – WEIGHTED AVERAGE

Emissions lb/MMBtu Output

CO Emissions g/min

Weighting Factor

Delivered Efficiency

Emissions g/MJ

Stack Loss Efficiency

Emissions g/hr

Category

Run No.

I

3

0.946

37.280

0.059

65.856

0.137

0.976

0.404

2

2

0.061

3.005

0.004

4.290

0.009

0.085

0.669

3

4

0.048

1.931

0.002

3.298

0.005

0.053

0.210

4

1

0.012

0.773

0.001

0.831

0.001

0.028

0.448

Totals

1.055

40.267

0.065

69.572

0.142

1.070

1.731

TABLE 4 - CSA B415.1 STACK LOSS RESULTS

RUN NO.

CO EMISSIONS (g/min)

HEATING EFFICIENCY (% HHV)

HEAT OUTPUT (Btu/hr)

3 2 4 1

1.62 2.68 0.84 1.79

69.60 70.10 69.00 67.00

27,524 30,288 41,565 48,998

SECTION 11 CONCLUSION

This test demonstrates that this unit is an affected facility under the definition given in the regulation. The emission rate of 0.142 lb/MMBtu Output meets the EPA requirements for the Step 2 limits. The models FC1000E, X1020, and L1020 are identical to the tested model SF1000E with the only differences being the exterior color and the name casted into the fuel door.

Version: 03/13/18

Page 17 of 25

RT-L-AMER-Test-3778

Made with FlippingBook - professional solution for displaying marketing and sales documents online