TEST REPORT FOR HY-C COMPANY, LLC Report No.: 104415176MID-002AR2 Date: 11/09/21
TABLE 3 – WEIGHTED AVERAGE
Emissions lb/MMBtu Output
CO Emissions g/min
Weighting Factor
Delivered Efficiency
Emissions g/MJ
Stack Loss Efficiency
Emissions g/hr
Category
Run No.
I
3
0.946
37.280
0.059
65.856
0.137
0.976
0.404
2
2
0.061
3.005
0.004
4.290
0.009
0.085
0.669
3
4
0.048
1.931
0.002
3.298
0.005
0.053
0.210
4
1
0.012
0.773
0.001
0.831
0.001
0.028
0.448
Totals
1.055
40.267
0.065
69.572
0.142
1.070
1.731
TABLE 4 - CSA B415.1 STACK LOSS RESULTS
RUN NO.
CO EMISSIONS (g/min)
HEATING EFFICIENCY (% HHV)
HEAT OUTPUT (Btu/hr)
3 2 4 1
1.62 2.68 0.84 1.79
69.60 70.10 69.00 67.00
27,524 30,288 41,565 48,998
SECTION 11 CONCLUSION
This test demonstrates that this unit is an affected facility under the definition given in the regulation. The emission rate of 0.142 lb/MMBtu Output meets the EPA requirements for the Step 2 limits. The models FC1000E, X1020, and L1020 are identical to the tested model SF1000E with the only differences being the exterior color and the name casted into the fuel door.
Version: 03/13/18
Page 17 of 25
RT-L-AMER-Test-3778