FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL: DATE:

Ken Slater

PROJECT #:

Brian Ziegler

PRODUCT: Wood Fired Furnace

SF1000E 9/23/20

SAMPLE ID #:

STANDARD(S): CSA B.415.1

VERSION YEAR:

LOCATION:

2010

Middleton

RESULTS

PASS

FAIL

X

NOPASS/FAIL

Weighted Average for Solid Fuel Aired Heating Appliances

CAT Load % Capacity

Tgt Load (Btu/hr)

Act Load (Btu/hr)

Test Duration (Hours)

WoodWt

Q in

Q out

h N

E T

E E Output

E Input

E

(Lb)

(Btu)

(Btu)

(%)

(g)

(g/MJ)

(lb/mmbtu) (lb/mmbtu)

(g/hr)

I

<35% of max

16,252 15,727

6.57

37.19

262,070

103,277

39.4%

6.78

0.06

0.14

0.06

1.03

II

35-53% of max 53-76% of max

24,611 21,540

5.82

35.58

255,004

125,290

49.1%

8.07

0.06

0.14

0.07

1.39

III

35,291 24,739

3.73

32.35

225,737

92,358

40.9%

4.10

0.04

0.10

0.04

1.10

IV

Max capacity 46,435 46,435

2.93

30.61

218,757

136,210

62.3%

6.71

0.05

0.11

0.07

2.29

Maximum output rating BTU/hr:

46,435

Weighted Average

Weighting

Direct h x F i

Stack Loss

Output

h x F i

E g/MJ,I x F i

E lb/mmbtu x F i

E g/hr x F i

CO g/hr x F i

CO g/min x F i

Category Factor

I

0.946 0.061 0.048 0.012 1.055

37.280 3.005 1.931 0.773 40.267

0.059 0.004 0.002 0.001 0.065

65.856 4.290 3.298 0.831 69.572

0.137 0.009 0.005 0.001 0.142

0.976 0.085 0.053 0.028 1.070

24.243 40.150 12.595 26.883

0.404 0.669 0.210 0.448 1.731

II

III IV

Totals

103.870

/Users/Admin/Dropbox (HY-C Company)/Marketing Projects/WAF [Fire Chief & Shelter]/Marketing | Intertek Docs/FC1000E & SF1000E EPA 2020 Certification Report_1.21/Appendix B - Data and Calculation Forms/[Weighted Avg SF1000E 9.21.20.xls]Sheet1 Remember to use Paste special when copying to this area, values only!

Weighted Avg SF1000E.xls

Made with FlippingBook - professional solution for displaying marketing and sales documents online