FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL:

Ken Slater

PROJECT #: G104415176

Brian Ziegler

PRODUCT:

SF1000E 9/16/20

Air Furnace

SAMPLE ID #: STANDARD(S):

DATE:

MID2009090750-001

VERSION YEAR:

LOCATION:

CSA B.415.1

2010

Middleton

4 1

Category

Run Number

30.61 20.27

Total Test Fuel Weight (lb)

Avg. Test Fuel Moisture (% dry)

Test Duration (min) Burn Rate (kg/hr)

176 3.94

Emissions (g)

6.71 Train 2

Beginning Dry Gas Meter Reading (ft3) Final Dry Gas Meter Reading (ft3) Average Barometric Pressure (“Hg) Average Delta p (inches of water)

0

0

23.60

24.22

29.215

0.093

Average Gas Velocity in Tunnel (feet/sec) 19 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 912.3206 kJ

Btu

Total Input Total Output

230647 218757 143,613 136210

kW

Output Rate (kJ/hr, BTU/hr, kW)

48,959

46435

13.60

Emissions g/MJ 0.046709 Emissions lb/MMBtu Input 0.067603 Emissions lb/MMBtu Output 0.108572

0.15 EPA 2020 Limit

2.28681 62.3%

Emissions g/hr

Efficiency

1 of 1