Intertek Testing Services
REPORT DATA
SFBA EPA ADJUSTED EMISSION RESULTS
RESULTS
Average emission rate:(gr/hr)
2.3
Burn Rate (Dry kg/hr):
3.936 Fuel Moisture (Dry):
20.27
Test Duration: 176
Stack Static (neg):
0.605
(minutes)
Barometer:
29.215
Average Room Temp:
75.41
BAROMETRIC PRESSURE
Average:
29.215
Start: End:
29.22 29.21
DRY GAS METER VALUES
Burn Rate:
3.936
VOLUMES SAMPLED
DGM #1 Final:
23.886
DGM #1: DGM #2:
23.59933 24.22043
Initial:
0.000
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
DGM #2 Final:
23.886
TOTAL TUNNEL VOLUME (scf):
160568
Initial:
0.000
Filter 1: Filter 2:
82.94 84.41 83.04 82.31 103.85
SAMPLE RATIOS
TEMPERATURES (DEG. RANKIN)
Tunnel:
Sample Train 1: Sample Train 2:
6803.940 6629.461
DGM #1: DGM #2:
543.041 542.306
DGM 1: DGM 2:
Water Collected:
TOTAL EMISSIONS
CALIBRATION FACTORS
6.12 7.29
Sample Train 1 (g): Sample Train 2 (g):
DGM #1: DGM #2:
0.9880 1.0140
Room Temp
Bar Pressure
Relative Humidity
Air Velocity
Before
After
Before 29.22
After
Before
After
Before After
76
0
29.21
56
54
0
0
EMISSION RATES
TUNNEL FLOW RATE:
912.321
2.09 2.49
Sample Train 1 (g/hr): Sample Train 2 (g/hr):
Pre-Test Load
Test Load
PARTICULATE CATCH (mg)
weight (wet lb)
Moisture Coal Bed Weight
Loading Density
Moisture Piece Number of
Total Sample Train 1: Total Sample Train 2:
(Dry %)
Weight
(wet lb)
(Dry %)
Length 2x4
4x4
0.9 1.1 0.9
32.50
22.42
7.5
30.61
9.003
20.27
20.00
Filter and seal Sample Train 1:
MAX Allowed
7.50% Filter and seal Sample Train 2:
1.1 Average Dilution Tunnel Measurements
Sample Data
Probe Sample Train 1: Probe Sample Train 2:
Burn
Velocity Flow Rate Temp Total Sample
Particulate Catch
0
DEVIATION:
17.42%
0 Time
(Ft/sec)
(dscf/min)
(R)
1
2
1
2
176
20.23 912.32 527.83 Dilution Tunnel Dual Train Precision
23.60
24.22
0.9
1.1
Train 1
Train 2
Room Particulate Correction
Cs Cr
3.81367E-05 4.54162E-05
Mr
Sample Ratios
Total Emissions (g)
0 Milligram Catch (mg)
0
0
Vmr
Train 1 Train 2 Train 1
Train 2 Deviation (%)
22.74624 Total Volume Sampled (dscf)
Et
6.12
7.29
6803.94 6629.46
6.12
7.29
17.42%
Rotometer (glass) at 100 flow rate is 0.12924 cfm
Change Surface
Et
AVERAGE
6.71 Grams Emissions
Burn Average Temp
Initial Draft
Run
Average Comb 62.852 68.1502
Rate 3.936
Catalyst
Surface
Temp
Time Draft Chamber
DEVIATION g/kg
#REF!
0.00
0.00
176 #DIV/0!
#REF!
Train #1: 0.53043 Train #2: 0.63168 Difference -0.1012
Run
Date Burn Rate Emission
0
1/0/00 3.936
2.287
Max Allowed
0.50
1 of 1
Made with FlippingBook - professional solution for displaying marketing and sales documents online