FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL:

Ken Slater

PROJECT #: G104415176 PRODUCT: Air Furnace

Brian Ziegler

SF1000E 9/16/20

SAMPLE ID #: STANDARD(S):

DATE:

MID2009090750-001

VERSION YEAR:

LOCATION:

CSA B.415.1

2010

Middleton

4 1

Category

Run Number

30.61 20.27

Total Test Fuel Weight (lb)

Avg. Test Fuel Moisture (% dry)

Test Duration (min) Burn Rate (kg/hr)

60

11.54

Emissions (g)

1.35 Train 2

Beginning Dry Gas Meter Reading (ft3) Final Dry Gas Meter Reading (ft3) Average Barometric Pressure (“Hg) Average Delta p (inches of water)

382.656 392.208 29.215

0 0

0.092

Average Gas Velocity in Tunnel (feet/sec) 21 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 1000.493 kJ

Btu

Total Input Total Output

230647 218757

kW

75,056 75,056

71187 71187

Output Rate (kJ/hr, BTU/hr, kW)

20.85

Emissions g/MJ 0.01793 Emissions lb/MMBtu Input 0.013563 Emissions lb/MMBtu Output 0.041678

0.15 EPA 2020 Limit

1.34578 32.5%

Emissions g/hr

Efficiency

1 of 1