FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL:

Ken Slater

PRODUCT: Air Furnace PROJECT #: G104415176

0

SF1000E 9/19/20

SAMPLE ID #: STANDARD(S):

DATE:

0

VERSION YEAR:

LOCATION:

CSA B.415.1

2010

Middleton

3 4

Category

Run Number

32.35 23.17

Total Test Fuel Weight (lb)

Avg. Test Fuel Moisture (% dry)

Test Duration (min) Burn Rate (kg/hr)

224 3.19

Emissions (g)

4.10 Train 2

Beginning Dry Gas Meter Reading (ft3) 0 Final Dry Gas Meter Reading (ft3) 30.11328 30.069892 Average Barometric Pressure (“Hg) 29.35 Average Delta p (inches of water) 0.093 0

Average Gas Velocity in Tunnel (feet/sec) 20 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 919.3931 kJ

Btu

Total Input Total Output

238006 225737

kW

97,378 26,083

92358 24739

Output Rate (kJ/hr, BTU/hr, kW)

7.25

Emissions g/MJ 0.042134 Emissions lb/MMBtu Input 0.040071 Emissions lb/MMBtu Output 0.097938

0.15 EPA 2020 Limit

Emissions g/hr 1.098991 Efficiency 40.9%

1 of 1