CLIENT: HY-C
PERFORMED BY: REVIEWED BY: MODEL:
Ken Slater
PRODUCT: Air Furnace PROJECT #: G104415176
0
SF1000E 9/19/20
SAMPLE ID #: STANDARD(S):
DATE:
0
VERSION YEAR:
LOCATION:
CSA B.415.1
2010
Middleton
3 4
Category
Run Number
32.35 23.17
Total Test Fuel Weight (lb)
Avg. Test Fuel Moisture (% dry)
Test Duration (min) Burn Rate (kg/hr)
224 3.19
Emissions (g)
4.10 Train 2
Beginning Dry Gas Meter Reading (ft3) 0 Final Dry Gas Meter Reading (ft3) 30.11328 30.069892 Average Barometric Pressure (“Hg) 29.35 Average Delta p (inches of water) 0.093 0
Average Gas Velocity in Tunnel (feet/sec) 20 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 919.3931 kJ
Btu
Total Input Total Output
238006 225737
kW
97,378 26,083
92358 24739
Output Rate (kJ/hr, BTU/hr, kW)
7.25
Emissions g/MJ 0.042134 Emissions lb/MMBtu Input 0.040071 Emissions lb/MMBtu Output 0.097938
0.15 EPA 2020 Limit
Emissions g/hr 1.098991 Efficiency 40.9%
1 of 1
Made with FlippingBook - professional solution for displaying marketing and sales documents online