FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

Intertek Testing Services

REPORT DATA

SFBA EPA ADJUSTED EMISSION RESULTS

RESULTS

Average emission rate:(gr/hr)

1.1

Burn Rate (Dry kg/hr):

3.191 Fuel Moisture (Dry):

23.17

Test Duration: 224

Stack Static (neg):

0.615

(minutes)

Barometer:

29.35 73.36

Average Room Temp:

BAROMETRIC PRESSURE

Average:

29.35 29.37 29.33

Start: End:

DRY GAS METER VALUES

Burn Rate:

3.191

VOLUMES SAMPLED

DGM #1 Final:

30.113

DGM #1: DGM #2:

29.75192 30.49087

Initial:

0.000

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

DGM #2 Final:

30.070

TOTAL TUNNEL VOLUME (scf):

205944

Initial:

0.000

Filter 1: Filter 2:

84.25 85.53 96.17 79.93 79.40

SAMPLE RATIOS

TEMPERATURES (DEG. RANKIN)

Tunnel:

Sample Train 1: Sample Train 2:

6922.043 6754.286

DGM #1: DGM #2:

539.928 539.404

DGM 1: DGM 2:

Water Collected:

TOTAL EMISSIONS

CALIBRATION FACTORS

4.15 4.05

Sample Train 1 (g): Sample Train 2 (g):

DGM #1: DGM #2:

0.9880 1.0140

Room Temp

Bar Pressure

Relative Humidity

Air Velocity

Before

After

Before 29.37

After

Before

After

Before After

73

0

29.33

40

38

0

0

EMISSION RATES

TUNNEL FLOW RATE:

919.393

1.11 1.09

Sample Train 1 (g/hr): Sample Train 2 (g/hr):

Pre-Test Load

Test Load

PARTICULATE CATCH (mg)

weight (wet lb)

Moisture Coal Bed Weight

Loading Density 10.141

Moisture Piece Number of

Total Sample Train 1: Total Sample Train 2:

(Dry %)

Weight

(wet lb)

(Dry %)

Length 2x4

4x4

0.6 0.6 0.6

32.00

23.14

7.0

32.35

23.17

20.00

Filter and seal Sample Train 1:

MAX Allowed

7.50% Filter and seal Sample Train 2:

0.6 Average Dilution Tunnel Measurements

Sample Data

Probe Sample Train 1: Probe Sample Train 2:

Burn

Velocity Flow Rate Temp Total Sample

Particulate Catch

0

DEVIATION:

2.45%

0 Time

(Ft/sec)

(dscf/min)

(R)

1

2

1

2

224

20.76 919.39 539.84 Dilution Tunnel Dual Train Precision

29.75

30.49

0.6

0.6

Train 1

Train 2

Room Particulate Correction

Cs Cr

2.01668E-05 1.9678E-05

Mr

Sample Ratios

Total Emissions (g)

0 Milligram Catch (mg)

0

0

Vmr

Train 1 Train 2 Train 1

Train 2 Deviation (%)

28.94976 Total Volume Sampled (dscf)

Et

4.15

4.05

6922.04 6754.29

4.15

4.05

2.45%

Rotometer (glass) at 100 flow rate is 0.12924 cfm

Change Surface

Et

AVERAGE

4.10 Grams Emissions

Burn Average Temp

Initial Draft

Run

Average Comb 62.852 68.1502

Rate 3.191

Catalyst

Surface

Temp

Time Draft Chamber

DEVIATION g/kg

#REF!

0.00

0.00

224 #DIV/0!

#REF!

Train #1: 0.34863 Train #2: 0.34019 Difference 0.00845

Run

Date Burn Rate Emission

0

1/0/00 3.191

1.099

Max Allowed

0.50

1 of 1

Made with FlippingBook - professional solution for displaying marketing and sales documents online