CLIENT: HY-C
PERFORMED BY: REVIEWED BY: MODEL:
Ken Slater
PROJECT #: G104415176 PRODUCT: Air Furnace
0
9/17/20 SF1000E
SAMPLE ID #: STANDARD(S):
DATE:
MID2009090750-001
VERSION YEAR:
LOCATION:
CSA B.415.1
2010
Middleton
2 2
Category
Run Number
35.58 19.92
Total Test Fuel Weight (lb)
Avg. Test Fuel Moisture (% dry)
Test Duration (min) Burn Rate (kg/hr)
349 2.31
Emissions (g)
8.07 Train 2
Beginning Dry Gas Meter Reading (ft3) Final Dry Gas Meter Reading (ft3) Average Barometric Pressure (“Hg) Average Delta p (inches of water)
0
0
46.50 29.20 0.096
47.73
Average Gas Velocity in Tunnel (feet/sec) 18 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 837.4436 kJ
Btu
Total Input Total Output
268864 255004 132,100 125290
kW
Output Rate (kJ/hr, BTU/hr, kW)
22,711
21540
6.31
Emissions g/MJ 0.061061 Emissions lb/MMBtu Input 0.069735 Emissions lb/MMBtu Output 0.141933
0.15 EPA 2020 Limit
Emissions g/hr 1.386722 Efficiency 49.1%
1 of 1
Made with FlippingBook - professional solution for displaying marketing and sales documents online