FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL:

Ken Slater

PROJECT #: G104415176 PRODUCT: Air Furnace

0

9/17/20 SF1000E

SAMPLE ID #: STANDARD(S):

DATE:

MID2009090750-001

VERSION YEAR:

LOCATION:

CSA B.415.1

2010

Middleton

2 2

Category

Run Number

35.58 19.92

Total Test Fuel Weight (lb)

Avg. Test Fuel Moisture (% dry)

Test Duration (min) Burn Rate (kg/hr)

349 2.31

Emissions (g)

8.07 Train 2

Beginning Dry Gas Meter Reading (ft3) Final Dry Gas Meter Reading (ft3) Average Barometric Pressure (“Hg) Average Delta p (inches of water)

0

0

46.50 29.20 0.096

47.73

Average Gas Velocity in Tunnel (feet/sec) 18 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 837.4436 kJ

Btu

Total Input Total Output

268864 255004 132,100 125290

kW

Output Rate (kJ/hr, BTU/hr, kW)

22,711

21540

6.31

Emissions g/MJ 0.061061 Emissions lb/MMBtu Input 0.069735 Emissions lb/MMBtu Output 0.141933

0.15 EPA 2020 Limit

Emissions g/hr 1.386722 Efficiency 49.1%

1 of 1

Made with FlippingBook - professional solution for displaying marketing and sales documents online