FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL:

Ken Slater

PROJECT #: G104415176 PRODUCT: Air Furnace

0

9/17/20 SF1000E

SAMPLE ID #: STANDARD(S):

DATE:

MID2009090750-001

VERSION YEAR:

LOCATION:

CSA B.415.1

2010

Middleton

2 2

Category

Run Number

35.58 19.92

Total Test Fuel Weight (lb)

Avg. Test Fuel Moisture (% dry)

Test Duration (min) Burn Rate (kg/hr)

60

13.46

Emissions (g)

2.69 Train 2

Beginning Dry Gas Meter Reading (ft3) Final Dry Gas Meter Reading (ft3) Average Barometric Pressure (“Hg) Average Delta p (inches of water)

392.24

0

401.822 8.0117433

29.195

0.094

Average Gas Velocity in Tunnel (feet/sec) 21 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 1007.227 kJ

Btu

Total Input Total Output

268864 255004

kW

46,670 46,670

44264 44264

Output Rate (kJ/hr, BTU/hr, kW)

12.96

Emissions g/MJ 0.05772 Emissions lb/MMBtu Input 0.023289 Emissions lb/MMBtu Output 0.134169

0.15 EPA 2020 Limit

Emissions g/hr 2.693828 Efficiency 17.4%

1 of 1

Made with FlippingBook - professional solution for displaying marketing and sales documents online