CLIENT: HY-C
PERFORMED BY: REVIEWED BY: MODEL:
Ken Slater
PROJECT #: G104415176 PRODUCT: Air Furnace
0
SF1000E 9/18/20
SAMPLE ID #: STANDARD(S):
DATE:
MID2009090750-001
VERSION YEAR:
LOCATION:
CSA B.415.1
2010
Middleton
1 3
Category
Run Number
37.19 21.97
Total Test Fuel Weight (lb)
Avg. Test Fuel Moisture (% dry)
Test Duration (min) Burn Rate (kg/hr)
394 2.11
Emissions (g)
6.78 Train 2
Beginning Dry Gas Meter Reading (ft3) Final Dry Gas Meter Reading (ft3) Average Barometric Pressure (“Hg) Average Delta p (inches of water)
0
0
52.42 29.37 0.098
53.79
Average Gas Velocity in Tunnel (feet/sec)
18
Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm)
830.239 kJ
Btu
Total Input Total Output
276314 262070 108,890 103277
kW
Output Rate (kJ/hr, BTU/hr, kW)
16,582
15727
4.61
Emissions g/MJ 0.062235 Emissions lb/MMBtu Input 0.057009 Emissions lb/MMBtu Output 0.144663
0.15 EPA 2020 Limit
Emissions g/hr 1.031997 Efficiency 39.4%
1 of 1
Made with FlippingBook - professional solution for displaying marketing and sales documents online