Intertek Testing Services
REPORT DATA
SFBA EPA ADJUSTED EMISSION RESULTS
RESULTS
Average emission rate:(gr/hr)
1.0
Burn Rate (Dry kg/hr):
2.106 Fuel Moisture (Dry):
21.97
Test Duration: 394
Stack Static (neg):
0.607
(minutes)
Barometer:
29.37 72.60
Average Room Temp:
BAROMETRIC PRESSURE
Average:
29.37 29.41 29.33
Start: End:
DRY GAS METER VALUES
Burn Rate:
2.106
VOLUMES SAMPLED
DGM #1 Final:
53.055
DGM #1: DGM #2:
52.41833 53.79316
Initial:
0.000
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
DGM #2 Final:
53.050
TOTAL TUNNEL VOLUME (scf):
327114
Initial:
0.000
Filter 1: Filter 2:
77.58 79.96 86.89 78.17 77.67
SAMPLE RATIOS
TEMPERATURES (DEG. RANKIN)
Tunnel:
Sample Train 1: Sample Train 2:
6240.455 6080.964
DGM #1: DGM #2:
538.172 537.668
DGM 1: DGM 2:
Water Collected:
TOTAL EMISSIONS
CALIBRATION FACTORS
6.86 6.69
Sample Train 1 (g): Sample Train 2 (g):
DGM #1: DGM #2:
0.9880 1.0140
Room Temp
Bar Pressure
Relative Humidity
Air Velocity
Before
After
Before 29.41
After
Before
After
Before After
72
0
29.33
40
37
0
0
EMISSION RATES
TUNNEL FLOW RATE:
830.239
1.05 1.02
Sample Train 1 (g/hr): Sample Train 2 (g/hr):
Pre-Test Load
Test Load
PARTICULATE CATCH (mg)
weight (wet lb)
Moisture Coal Bed Weight
Loading Density 10.938
Moisture Piece Number of
Total Sample Train 1: Total Sample Train 2:
(Dry %)
Weight
(wet lb)
(Dry %)
Length 2x4
4x4
1.1 1.1 1.1
35.90
22.00
5.3
37.19
21.97
20.00
Filter and seal Sample Train 1:
MAX Allowed
7.50% Filter and seal Sample Train 2:
1.1 Average Dilution Tunnel Measurements
Sample Data
Probe Sample Train 1: Probe Sample Train 2:
Burn
Velocity Flow Rate Temp Total Sample
Particulate Catch
0
DEVIATION:
2.59%
0 Time
(Ft/sec)
(dscf/min)
(R)
1
2
1
2
394
20.36 830.24 586.65 Dilution Tunnel Dual Train Precision
52.42
53.79
1.1
1.1
Train 1
Train 2
Room Particulate Correction
Cs Cr
2.0985E-05 2.04487E-05
Mr
Sample Ratios
Total Emissions (g)
0 Milligram Catch (mg)
0
0
Vmr
Train 1 Train 2 Train 1
Train 2 Deviation (%)
50.92056 Total Volume Sampled (dscf)
Et
6.86
6.69
6240.46 6080.96
6.86
6.69
2.59%
Rotometer (glass) at 100 flow rate is 0.12924 cfm
Change Surface
Et
AVERAGE
6.78 Grams Emissions
Burn Average Temp
Initial Draft
Run
Average Comb 62.852 68.1502
Rate 2.106
Catalyst
Surface
Temp
Time Draft Chamber
DEVIATION g/kg
#REF!
0.00
0.00
394 #DIV/0!
#REF!
Train #1: 0.49634 Train #2: 0.48365 Difference 0.01269
Run
Date Burn Rate Emission
0
1/0/00 2.106
1.032
Max Allowed
0.50
1 of 1
Made with FlippingBook - professional solution for displaying marketing and sales documents online