CLIENT: HY-C
PERFORMED BY: REVIEWED BY: MODEL:
Ken Slater
PRODUCT: Air Furnace PROJECT #: G104415176
0
SF1000E 9/18/20
SAMPLE ID #: STANDARD(S):
DATE:
MID2009090750-001
VERSION YEAR:
LOCATION:
CSA B.415.1
2010
Middleton
1 3
Category
Run Number
37.19 21.97
Total Test Fuel Weight (lb)
Avg. Test Fuel Moisture (% dry)
Test Duration (min) Burn Rate (kg/hr)
60
13.83
Emissions (g)
1.36 Train 2
Beginning Dry Gas Meter Reading (ft3) Final Dry Gas Meter Reading (ft3) Average Barometric Pressure (“Hg) Average Delta p (inches of water)
401.842
0
411.406 8.1132843
29.37 0.098
Average Gas Velocity in Tunnel (feet/sec) 22 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 1023.727 kJ
Btu
Total Input Total Output
276314 262070
kW
32,041 32,041
30389 30389
Output Rate (kJ/hr, BTU/hr, kW)
8.90
Emissions g/MJ 0.042381 Emissions lb/MMBtu Input 0.011423 Emissions lb/MMBtu Output 0.098513
0.15 EPA 2020 Limit
Emissions g/hr 1.357913 Efficiency 11.6%
1 of 1