FC1000E/SF1000E/X1020/L1020: EPA 2020 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL:

Ken Slater

PRODUCT: Air Furnace PROJECT #: G104415176

0

SF1000E 9/18/20

SAMPLE ID #: STANDARD(S):

DATE:

MID2009090750-001

VERSION YEAR:

LOCATION:

CSA B.415.1

2010

Middleton

1 3

Category

Run Number

37.19 21.97

Total Test Fuel Weight (lb)

Avg. Test Fuel Moisture (% dry)

Test Duration (min) Burn Rate (kg/hr)

60

13.83

Emissions (g)

1.36 Train 2

Beginning Dry Gas Meter Reading (ft3) Final Dry Gas Meter Reading (ft3) Average Barometric Pressure (“Hg) Average Delta p (inches of water)

401.842

0

411.406 8.1132843

29.37 0.098

Average Gas Velocity in Tunnel (feet/sec) 22 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 1023.727 kJ

Btu

Total Input Total Output

276314 262070

kW

32,041 32,041

30389 30389

Output Rate (kJ/hr, BTU/hr, kW)

8.90

Emissions g/MJ 0.042381 Emissions lb/MMBtu Input 0.011423 Emissions lb/MMBtu Output 0.098513

0.15 EPA 2020 Limit

Emissions g/hr 1.357913 Efficiency 11.6%

1 of 1