Amtech ATC Cyclone Dust Collector Series User Manual

REMOTE CONNECTION AFTERFILTER ASSEMBLY

Note: Do not tighten bolts until all parts and panels are in place.

Position hopper/leg assembly. Note slide gates and orient the slide for easy access for dust drum removal.

Raise Afterfilter housing assembly with hydraulic lift truck forks (or other suitable means) and set on top of hopper / leg assembly with bolt holes aligned. Secure with 3/8” – 16 hardware. Leave hardware hand tightened until all hardware is in place. Tighten all hardware connections. Remove support. Raise plenum assembly with hydraulic lift truck forks (or other suitable means) and set on top of afterfilter assembly with bolt holes aligned. Secure with 3/8” – 16 hardware. Leave hardware hand tightened until all hardware is in place. Tighten all hardware connections. Remove support. Install bags, hold end of the bag and adjust the bag clamp to seat bag in the plenum assembly. Start at the back corner of the unit. Repeat this procedure for each bag. Continue working toward the front of the unit until all bags are installed.

ROTARY AIRLOCK INSTALLATION

If a rotary airlock was ordered with the unit, remove all packing from the rotary airlock and determine its appropriate position. Keep in mind required clearances, electrical connections and maintenance. Apply sealant to the flange of the rotary airlock and fasten to the adapter using bolts, nuts, washers and lock washers provided. All electrical connections must be performed by a qualified electrician according to all applicable codes. Refer to the nameplate and/or attached documentation for voltage, amperage, cycle and proper wiring. NOTE:

DUST SILENCER INSTALLATION

A duct-type silencer is designed to bolt directly to the fan outlet flange. Make sure there is adequate room for the silencer in the direction of discharge. Provide at least 60 ” of unobstructed space at the end of the silencer discharge. The air discharge should be directed into an open area free of obstructions and with consideration for personnel safety. The silencer will require separate support. DO NOT use the fan or outlet flange to support the silencer. Apply silicone around the bolt holes of the connecting flanges, lift the silencer into position and secure with the hardware provided. Install permanent supports (not supplied by Clean Air Industries ) and tighten all hardware before removing the lifting device.

Page 11

sales@clean-air.com

1-866-665-1829

www.clean-air.com

Made with FlippingBook Annual report maker