Amtech ATC Cyclone Dust Collector Series User Manual

DRUM LID INSTALLATION

Remove the drum lid package from its shipping carton. Place the drum lid on a standard 55 gallon drum. Slide the 8” hose over the drum lid and secure with a hose clamp. Position the drum assembly(s) under the unit, slide the hose up onto the discharge adapter collar on the cone and secure with a hose clamp.

4.5 ELECTRICAL INSTALLATION

!!!!! CAUTION !!!!!

All electrical work should be done by a qualified electrician in accordance with local codes. Disconnect electrical power before installing or servicing any electrical equipment. See Figure 3 for wiring connections.

Note: All electrical work must be performed by a qualified electrician according to the most stringent applicable codes. Be sure to use proper size starter, conduit and wiring for blower motor.

Start fan motor and visually check for proper rotation as indicated by the “rotation arrow” decal on the fan housing.

Note: While rotating backwards, the fan will still deliver approximately 40% of its rated air volume but will require more horsepower than proper rotation. It is extremely important to ensure proper fan rotation. If your collector has a belt-driven blower wheel, DO NOT attempt to make any pulley changes. Each pulley is sized for proper operation prior to shipment. No changes should be made unless specifically directed by Clean Air Industries .

Page 12

sales@clean-air.com

1-866-665-1829

www.clean-air.com