SELF-CENTERING VISES PRECISION, DURABILITY, VERSATILITY
HYDRAULIC PNEUMATIC HIGH PRESSURE
www.vektek.com
072426
PNEUMATIC SELF-CENTERING VISE
Pneumatic Self-Centering Vise
Max operating pressure 9 or 6 bar. High jaw repeatability: VFB 66-100: 0.01MM VFB 160-200: 0.02MM
VFB 250: 0.03MM over 100 cycles
Wedge and piston design. Stroke range from 4 to 30MM. Operating temperature range from 5 to 60°C. Hardened steel construction. Pneumatic connections on the side or bottom.
Specifications
OPEN
F
Jaw Stroke per Jaw (mm)
Clamping Force kN (lbs)*
Max Pressure bars (psi)
Max Jaw Length (mm)
Open/ Close Time (s)
Air Consumption per Stroke Cycle (cm^3)
Vise Weight (kg)
Model Number
F (mm)
Version
VFB 66 C1 10 4.5 (1,010) 9 (130)
2 6 2 8 3
60
0.1
30
1.5
C1 C2 C1 C2 C1 C2 C1 C2
7.6 (1,700) 19 (4,270) 20 (4,500) 48 (10,800) 22 (4,950) 52 (11,700) 22 (4,950) 55 (12,365)
150
VFB 100
16
9 (130)
0.2
135
4.5
60
200
VFB 160
25
9 (130)
0.4
500
14
60
10
280 105 500
VFB 200
32
9 (130)
0.85
685
23
4
ILM450007 REV C
15
VFB 250
40
6 (87)
1
1420
35
5 150 * The gripping force is the arithmetic sum of the individual forces at “F” distance at max pressure.
** Closing and opening times are purely the times that the base jaws are in motion. Valve switching, hose filling, PLC/CNC reactions, and other potential delays are not included and must be taken into consideration when determining cycle times.
F A
M
M
x
y
Y
Z
Load Data Type F A (N) M y (Nm) M z (Nm) M x (Nm) VFB 66 2000 75 75 75 VFB 100 5000 250 250 250 VFB 160 10000 500 500 500 VFB 200 13500 800 800 800 VFB 250 22000 1200 1200 1200 The shown force and moments are applied per base jaw and may occur simultaneously.
X
M
z
ILM450011 REV A
1
PNEUMATIC SELF-CENTERING VISE
-0.1 -0.3
A
LUBRICATION
B
B 0.01
*VERSION Z ON REQUEST N 0.01 TO CLAMPING CENTER J 0.01
CLOSE
H7
2x V
n
5
1
U
C
-0.1 -0.3
d14
E
NOTE: VISE SHOWN IN CLOSED STATE
4
2
D
3
A
2x m
d7
AIR PURGE
OPEN
d12
H
*t 0.01
0.02 A .02 A
b d
*N
0.1 B 0.01 C
SLOTS FOR INDUCTIVE PROXIMITY SWITCHES d11
Y
a
W
g6
k
d9
.02 C
60
d2
f
3
e
d1
2x X
d13
d5
L
OPEN Z d10
AIR PURGE M5/M3
CLOSE Z d10
C
T
H7
G QTYxDIST
d8
P
AIR PURGE M5/M3
R S
ILM450009 REV E
d3
d15
4x h
d4
d6
GREASE FITTINGS DIN 3405 AM6
2
PNEUMATIC SELF-CENTERING VISE
Pneumatic Type ABCDE GHLMPRS UVZ XYW J K a b VFB 66 66 42 34 29.5 66 3x5 54 37 59 4 M4 6.5 18.5 4 M5 15 2.7 1.8 53 14 30 43 VFB 100 102 64 50 45 102 4x7 80 63 90 6 M6 9 31 6 M5 20 2.7 1.8 71.5 20 47 66 VFB 160 160 110 78 55 160 5x10 140 103 140 8 M8 13 51.5 8 G1/8 16 3.2 1.8 88.5 32 78 104 VFB 200 200 130 106 65 200 7x10 164 128 186 8 M8 13 64 8 G1/8 18 4 2.3 93.5 40 102 140 VFB 250 254 156 124 79 254 7x12 202 159 232 10 M10 18 79.5 10 G1/8 18 4 2.3 103 50 125 170
T N d8 T N d8
Type d d1 d2 d3 d4 d5 d6 d7 d9 d10 d11 d12 d13d14d15 e f
p t
C1 C2 VFB 66 38 26 49.5 24 11 N/A 12 19.5 26.3 6 N/A 23 16 54 34 30 N/A 10.226.4 15.8 N/A N/A N/A 40 59 VFB 100 58 34 68 35 13.5 40 19 31 41 6 M5 37 15 80 51 38 55.714.5 51 19.5 15 52 19 66 93 VFB 160 91 25 84.8 60 18 48 24 70 67.5 9 M5 62 49.5 140 78 47.5 71 18.889.6 27.2 19 90 27 81 149 VFB 200 118 35 89.5 74 19 65 27 87 85.5 9 M8 91.5 54 164 106 51 74 20 92 46 20 92 46 149 186 VFB 250 142 45 98.8 90 19 86 35 109 108.5 9 M8 119 58 202 124 55 81 32.5 103 65.5 25 112 61 182 225
Feed Hole 1 and 2 Lubrication
Feed Hole 4 and 5 Actuation
Feed Hole 3 Air Purge
Type h m n VFB 66 6.5 21 7.5 VFB 100 8.5 31.5 12 VFB 160 11 52 14 VFB 200 13 66 14 VFB 250 13 88.5 18
Type
A
D A D A
D
VFB 66 Ø3.5x1 2.5 Ø3.5x1 2.5
Ø4x1
2.5
VFB 100 Ø5x1.5 3.5 Ø5x1.5 3.5 Ø6x1.5 VFB 160 Ø5x1.5 3.5 Ø5x1.5 3.5 Ø6x1.5
4 4 5 5
VFB 200 Ø6x1.5 VFB 250 Ø6x1.5
4 4
Ø6x1.5 Ø6x1.5
4 4
Ø7x1.5 Ø7x1.5
For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a .
O-RING A
VISE
MOUNTING SURFACE
D
ILM450009 REV E
3
HYDRAULIC SELF-CENTERING VISE
Max operating pressure 60 or 120 bar. High jaw repeatability: VFB 66-100: 0.01MM VFB 160-200: 0.02MM Hydraulic Self-Centering Vise
VFB 250: 0.03MM over 100 cycles
Wedge and piston design. Stroke range from 4 to 30MM. Operating temperature range from 5C to 60°C. Hardened steel construction. Hydraulic connections in the side or bottom.
Specifications
F
Jaw Stroke per Jaw (mm)
Clamping force kN (lbs)*
Max Pressure bars (psi)
Max Jaw Length (mm)
Close/ Open Time (s)
Oil Consumption per Stroke Cycle (cm^3)***
Vise Weight (kg
F (mm)
Type Version
VFB 66 C1 10 6.8 (1,530) 60 (870)
2 6 2 8 3
60 0.5
10
1.5
C1 C2 C1 C2
16 (3,600) 120 (1,740)
VFB 100
16
60
1
33
4.9
20 (4,500)
60 (870)
44 (9,900) 120 (1,740) 54 (12,140) 60 (870)
VFB 160
25
60 1.5
105
14.5
VFB 200 C1 32 56 (12,600) 60 (870) VFB 250 C1 40 62 (13,940) 60 (870)
10 15
95 2.3
240 440
24 37
ILM450008 REV D
140
3
* The gripping force is the arithmetic sum of the individual forces at “F” distance at max pressure. ** Closing and opening times are purely the times that the base jaws are in motion. Valve switching, hose filling, PLC/CNC reactions, and other potential delays are not included and must be taken into consideration when determining cycle times. *** The max recommended flow rate is 2L/min.
F A
M
M
x
y
Y
Z
Load Data Type F A (N) M y (Nm) M z (Nm) M x (Nm) VFB 66 2000 75 75 75 VFB 100 5000 250 250 250 VFB 160 10000 500 500 500 VFB 200 13500 800 800 800 VFB 250 22000 1200 1200 1200 The shown force and moments are applied per base jaw and may occur simultaneously.
X
M
z
ILM450011 REV A
4
HYDRAULIC SELF-CENTERING VISE
-0.1 -0.3
A
LUBRICATION
B
B 0.01
*VERSION Z ON REQUEST N 0.01 TO CLAMPING CENTER J 0.01
CLOSE
H7
2x V
n
5
1
C
-0.1 -0.3
d14 U
E
NOTE: VISE SHOWN IN CLOSED STATE
4
2
D
3
A
d7
2x m
OPEN
AIR PURGE
d12
H
*t 0.01
0.02 A .02 A
b d
*N
0.1 B 0.01 C
SLOTS FOR INDUCTIVE PROXIMITY SWITCHES d11
Y
a
W
g6
k
d9
.02 C
60
d2
f
3
e
d1
2x X
d13
d5
L
OPEN Z d10
AIR PURGE M5/M3
CLOSE Z d10
C
T
H7
G QTYxDIST
d8
P
AIR PURGE M5/M3
R S
ILM450057 REV A
d3
d15
4x h
d4
d6
GREASE FITTINGS DIN 3405 AM6
5
HYDRAULIC SELF-CENTERING VISE
Hydraulic Type ABCDE GHLMPRS UVZ XYW J K a b VFB 66 66 42 34 28 66 5x3 54 27 59 4 M4 6.5 35 4 G1/8 15 2.7 1.8 53 14 30 43 VFB 100 102 64 51 44.5 102 7x4 80 34 90 6 M6 9 34 6 G1/8 20 2.7 1.8 71.5 20 47 66 VFB 160 160 110 78 55 160 10x5 140 42 140 8 M8 13 42 8 G1/8 16 3.2 1.8 88.5 32 78 104 VFB 200 200 130 106 65 200 10x7 164 70 186 8 M8 13 70 8 G1/8 18 4 2.3 93.5 40 102 140 VFB 250 254 156 124 79 254 12x7 202 96 189 10 M10 18 96 10 G1/8 18 4 2.3 103 50 125 170
T N d8 T N d8
Type d d1 d2 d3 d4 d5 d6 d7 d9 d10 d11 d12 d13d14d15 e f
p t
C1 C2 VFB 66 38 26 49.5 24 11 N/A 12 19 26.3 8 N/A 25 16 54 34 30 N/A 10.226.4 15.8 N/A N/A N/A 20 59 VFB 100 58 34 68 35 13.5 40 19 31 41 8 M5 37.2 15 80 51 38 55.714.5 51 19.5 15 52 19 66 93 VFB 160 91 25 84.8 60 18 48 24 70 67.5 9 M5 62 49.5 140 78 47.5 71 18.889.6 27.2 19 90 27 81 149 VFB 200 118 35 89.5 74 19 65 27 87 85.5 9 M8 91.5 54 164 106 51 74 20 92 46 N/A N/A N/A 149 186 VFB 250 142 45 98.8 90 19 86 35 109 108.5 9 M8 119 58 189 124 55 81 32.5 103 65.5 N/A N/A N/A 182 225
Feed Hole 1 and 2 Lubrication
Feed Hole 4 and 5 Actuation
Type h m n VFB 66 6.5 25 7.5 VFB 100 8.5 40 12 VFB 160 11 68 14 VFB 200 13 88 14 VFB 250 13 115 18
Feed Hole 3 Air Purge
Type A D A D VFB 66 Ø2.5x1 2.5 Ø2.5x1 2.5 Ø5x1.5 3.5 VFB 100 Ø5x1.5 3.5 Ø5x1.5 3.5 Ø6x1.5 4 VFB 160 Ø5x1.5 3.5 Ø5x1.5 3.5 Ø7x1.5 5 VFB 200 Ø6x1.5 4 Ø6x1.5 4 Ø7x1.5 5 VFB 250 Ø6x1.5 4 Ø6x1.5 4 Ø7x1.5 5 D A
ILM450057 REVA
For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a .
O-RING A
VISE
MOUNTING SURFACE
ILM450057 REV A
D
6
VISE CONFIGURATOR
VFB VFB
160 160
C1 C1
PN PN
7
VISE APPLICATION WORKSHEET
CUSTOMER INFORMATION
Customer Contact Phone Number Email Date Date Needed Quan i ty
VISE
INFORMATION
Type of vise (hydraulic or pneuma ti c) Supply pressure Stroke per jaw Repeatability required Clamping force Top jaw length (from base jaw) One fi xed jaw? (Yes or No) Safety device? If yes in what version: MC or MA
EXTERNAL LOAD
INFORMATION
FZ (Axial Force) in N MX (Moment about the X axis) in Nm MY (Moment about the Y axis) in Nm MZ (Moment about the Z axis) in Nm
MX
FZ
MY
MZ
WORK ENVIRONMENT REQUIRING OPTIONS
INFORMATION
Temperature range of work environment Applica ti on (grinding, assembly, machining, welding, other) IP ra ti ng required - Is there coolant, heavy dust, debris or oil present?
OPERATIONAL PREFERENCES
INFORMATION
Time to open/closed jaws (for each direc ti on) Preferred loca ti on for hydraulic supply connec ti ons
Side
Base
Manifold
POSITION SENSING
No Yes, include sensing kit
8
HIGH PRESSURE SELF-CENTERING VISE
Hydraulic 250 bar Self-Centering Vise Max operating pressure 250 bar. High jaw repeatability: VCV 100: 0.01MM VCV 160: 0.02MM Wedge and piston design. Stroke range from 12 to 16MM. Operating temperature range from 5C to 60 ° C. Hardened steel construction. Hydraulic connections in the side or bottom. Inductive sensors can be mounted for open, close, and part clamp detection. Requires the use of the S mounting kit. The VCV ships with the following mounting hardware: two spring pins, two shoulder bolts, two locating pins, and manifold mount o-rings. The PC option adds the ability for pneumatic part presense sensing and blow off when manifold mounted by adding a pneumatic port in the top of the jaw. The MB option adds the ability for pneumatic jaw position sensing for clamp and unclamp. Each state uses a separate port, so they can be used individually to detect a single state, or together to also verify part clamping.
F
ILM450024 REV C
Specifications
Jaw Stroke per Jaw (mm)
Clamping Force kN (lbs.)*
Max Pressure bars (psi)
Max Jaw Length (mm)
Close/ Open Time(s)**
Oil Consumption per Stroke Cycle (cm^3)***
Vise Weight (kg)
Model Number
F (mm)
VCV 100 16 16 (3,600) 250 (3,625) VCV 160 25 44 (9,900) 250 (3,625)
6 8
60 60
1
16 49
4.9
1.5
14.5
* The gripping force is the arithmetic sum of the individual forces at “F” distance at max pressure. ** Closing and opening times are purely the times that the base jaws are in motion. Valve switching, hose filling, PLC/CNC reactions, and other potential delays are not included and must be taken into consideration when determining cycle times. *** The max recommended flow rate is 2L/min.
PC AIR SUPPLY TO JAWS
PC AIR SUPPLY TO JAWS
MB VENTS UNDER JAW
VCV Sensing Options The PC option adds the ability for pneumatic part presense sensing and blow off when manifold mounted by supplying compressed air to the jaws. This air can be routed through jaws and used to blow off the jaw faces before machining, or the port can be positioned to be covered by the part to increase air pressure and verify part presence. The MB option adds the ability for pneumatic jaw position sensing for fully clamped and unclamped. Each state uses a seperate port, so they can be used individually to detect a single state, or together to also verify part clamping. Use max of 2 bar air pressure. Can be used with 50-8240-00 air sensing control kit.
MB VENTS UNDER JAW
MB AIR INPUT
PC AIR INPUT
MB AIR INPUT
PC AIR INPUT
ILM450054 REV A
ILM450054 REV A
MB PORT LOGIC
MB PORT LOGIC
PORT 4
MAX PSI
PORT 4
MAX PSI
<5PSI
<5PSI
PORT 6 MAX PSI
PORT 6 MAX PSI
<5PSI
<5PSI
FULLY EXPANDED
FULLY RETRACTED
FULLY EXPANDED
FULLY RETRACTED
9
HIGH PRESSURE SELF-CENTERING VISE
F
A
Y
M
M
x
y
X
M
z
Y
ILM450025 REV A
Z
THE SHOWN FORCE AND MOMENTS ARE APPLIED PER BASE JAW AND MAY OCCUR SIMULTANEOUSLY.
Load Data Type F A (N) M y (Nm) M z (Nm) M x (Nm) VCV 100 5000 250 250 250 VCV 160 10000 500 500 500
X
M
z
HIGH PRESSURE VISE CONFIGURATOR
ILM450025 REV A
VCV
160
C1
ID
10
HIGH PRESSURE SELF-CENTERING VISE
-0.1 -0.3
V H7 n
A
****2X ISO 7379 q r s THRU
2x m
D 2x m
3x Q
MANIFOLD HOLES 1:UNCLAMP (# ALTERNATE LOCATION ON REQUEST) 2:CLAMP 3:***JAW 1 AIR SUPPLY 4:**PNEUMATIC UNCLAMP MONITORING 5:***JAW 2 AIR SUPPLY 6:**PNEUMATIC CLAMP MONITORING 7:LUBRICATION 8:AIR PURGE
2
7
8
3
U
d7
2x d16
6
-0.1 -0.3
d14
C
E
1#
4
5
U
*VERSION Z ON REQUEST N 0.01 **REQUIRES MB OPTION ***REQUIRES PC OPTION
7
1
A
2x d12
NOTE: VISE SHOWN IN CLOSED STATE
*t 0.01 H B 0.01
0.02 A .02 A
B
a d b
*N
0.1 B 0.01 C
SLOTS FOR INDUCTIVE PROXIMITY SWITCHES d11
Y
.02 C
W
g6
d9
k
60
d2
f
3
e
d1
2x X
d13
AIR PURGE M5
d5
C
AIR PURGE M5 SIZE 100 ONLY
CLOSE Z d10
OPEN Z d10
L
H7 T
d8
P
G QTYxDIST
****DIN EN ISO 4762 2x h
R S
****IF USING 4X DIN EN ISO 4762 BOLTS, 2X DIN EN ISO 13337 SPRING PINS CAN BE USED. OR USE 2X BOLTS AND 2X ISO 7379 SHOULDER BOLTS ACCURACY TO CLAMPING CENTER FOR MOUNTING OPTIONS: -SPRING PINS: +/-0.04 -SHOULDER BOLTS: +/-0.02
d3
d15
2x v
d4
d6
ILM450026 REV E
GREASE FITTINGS DIN 3405 AM6
2x u
11
HIGH PRESSURE SELF-CENTERING VISE
Hydraulic 250 bar TypeABCDE G H LMPRS UVZ XYW J K Q a VCV 100 102 64 55 40 100 7x4 80 57 90 6 M6 9 29.5 6 G1/8 15 2.7 1.8 74.2 20 32 47 VCV 160 160 106 82 67 160 10x5 125 100 146 8 M8 12 50 8 G1/8 15 3.2 1.8 87.2 32 40 78
T N d8 C1
Type b d d1 d2 d3 d4 d5 d6 d7 d9 d10 d11 d12 d13 d14 d15 d16 e f
VCV 100 66 58 21 70 35 13.5 40 19 18.7 41 8 M5 34.5 15 80 51 19 38 55.7 14.5 51 19.5 VCV 160 104 91 25 83.6 60 18 48 24 29 67.5 9 M5 59.7 49.5 125 78 24 47.5 71 18.8 89.6 27.2
Dimensions
Type hmnpqrst u v VCV 100 8.5 43 12 90 11 7.5 10 64 13.5 13 VCV 160 11 72 14 146 13 10 12 106 22.2 30
HOLE #
A
B C D
1-8
Ø 5.25X1.78 8.8 1 4
For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a .
A O-RING
VISE
MOUNTING SURFACE
C
D
FEED HOLE
B
ILM450026 REV E
12
SELF-CENTERING MANUAL VISE
The VZS has multiple mounting options, including mounting bolts, side slots for setup clamps, and Zero-points. High jaw repeatability: 0.01MM over 100 cycles. Stroke range from 20 to 150MM. Operating temperature range from 5 to 60C. Hardened steel construction. The size 80 , 90, and 125 have an option for centering fixture pins. Self-Centering Manual Vise VZS
Self-Centering Manual Vise VZS Specifications
Full Clamp Range with Standard Jaw Blanks (mm)
Max Torque (Nm)
Clamping force kN (lbs)*
Per Jaw Stroke (mm)
Model Numer
Max Jaw Length at Given Torque 30mm at 50 Nm 50mm at 30 Nm 35mm at 55 Nm 80mm at 20 Nm 50mm at 85 Nm 105mm at 40 Nm 70mm at 155 Nm 150mm at 70 Nm
Vise Weight (kg)
Version
1 2
10 50
0 to 76 0 to 156
2.5 3.9
VZS-70
50 16.3 (3,660)
VZS-80 1
55 18 (4,050)
15
0 to 96
3.5
VZS-90 1
85 27 (6,070)
25
0 to 142
5.9
1 2
30 75
0 to 190 0 to 280
14.2
VZS-125
155 37 (8,320)
18
ILM450059 REVA
Self-Centering Manual Vise VZS Load Data
F
A
M
M
Y
X
Z
Y
VZS Load Data Type F A (kN) M y (Nm) M z (Nm) M x (Nm) VZS-70 2.5 65 75 80 VZS-80 6 80 120 120 VZS-90 18 100 210 210 VZS-125 24 135 240 240
X
M
Z
ILM450061 REV A
13
G 0.01
SELF-CENTERING MANUAL VISE
L 0.01
A
H
J 0.01
B
.02 C
R FULLY OPEN
K
H7
H6
X
d19
0.8 B 0.01 C
0.02 A 0.02 A
H7
M
F
SEE DETAIL A
V
STROKE
G 0.01
d1
H7
Y Z
T
W
30°
d11
L 0.01
P
Q
A
H
M10
U
d8
d10
C
BOLT SIZE
N
.02 C
d6
S
d7
R FULLY OPEN
C
D 0.05
H7
d9
H7
X
DIN 71412 AM6
E 0.02
0.8 B 0.01 C
0.02 A 0.02 A
d2
ILM450060 REV A
d3
F
SEE DETAIL A
V
STROKE
d4
d1
H7
Y Z
T
W
30°
d11
d5
B d18 0.02
P
Q
M10
U
d8
d10
C
BOLT SIZE
N
d6
S
d7
C
A
D 0.05
H7
d9
DIN 71412 AM6
E 0.02
OPTION CP CENTERING BUSHINGS
d2
ILM450060 REV A
n6
d13
d3
d14
d4
d17
d15
d5
B d18 0.02
d16
SCALE .400 DETAIL A
A
OPTION CP CENTERING BUSHINGS
d13 VZS Dimensions Type ABCDEFGHJKLMNPQRSTUVW VZS-70 90 80 93 47 52 61 67 62 38 N/A N/A N/A N/A N/A 20 54 9 38 50 11.5 8 VZS-70-2 170 80 173 47 52 61 67 128 102 N/A 0* 12 1.4 12 20 134 9 38 50 11.5 8 VZS-80 122 78 133 51 56 61 65 92 68 N/A 0* 12 6.5 15 24 81 9 40 49 17 8 VZS-90 170 90 190 53 58 70 74 128 102 N/A 0* 12 6.5 15 24 119 10 44 56 26 8 VZS-125-1 240 125 261 65 70 95 106 160 130 N/A N/A 18 5 N/A 27 157 12 64 79 40 10 VZS-125-2 330 125 351 65 70 95 106 280 250 90 200 18 5 15 27 247 12 64 79 40 10 Type X Y Z d1 d2 d3 d4 d5 d6 d7 d8 d9 d10 d11 d12 d13 d14 d15 d16 d17 d18 d19 VZS-70 12 M6 12 5 30 10.5 5 23 13 8.5 M8 8 11 N/A N/A N/A N/A N/A N/A N/A N/A N/A VZS-70-2 12 M6 12 5 30 10.5 5 23 13 8.5 M8 8 11 N/A N/A N/A N/A N/A N/A N/A N/A 25 VZS-80 12 M6 11 4 42 24 9 27 17 8.5 M8 8 14 10 17 10 4.5 5.5 16 M6 38 25 VZS-90 12 M8 14 4 60 34 13 28 17 10.5 M10 8 14 10 17 10 4.5 5.5 18 M6 39 25 VZS-125-1 16 M10 16 5 90 56 17 46 20 13 M12 10 16 13 20 12 4.5 5.5 21 M8 54 N/A VZS-125-2 16 M10 16 5 90 56 17 46 20 13 M12 10 16 13 20 12 4.5 5.5 21 M8 54 25 NOTE: * Zero-point is centered on the vise. n6 d17 d15 d14 d16 SCALE .400 DETAIL A
14
ACCESSORIES
C
B
JAWS SOLD AS A SET OF TWO.
MILLABLE AREA
C
B
JAWS SOLD AS A SET OF TWO.
MILLABLE AREA
Vise Lubricant
Vise Lubricant
C
B
JAWS SOLD AS A SET OF TWO.
MILLABLE AREA
Part Number
Description D
F
TP-42 Molykote is the recommended grease for use with Vektek vises.
D
F
65-0004-00
500g grease gun cartridge
D
F
A
A
E
VFB/VCV Vise Jaw Blanks
E
H
A
H
E
H
C
B
JAWS SOLD AS A SET OF TWO.
MILLABLE AREA
D
F
G
G
G
A
E
H
MH-VFB Jaws
Number MH-VFB-66
A
B
C D E
F
G H
5
18.5
4 9
11 18 30 32 35
14 16 24 45 54
16 25 40 45
31 47 76
34 55 80
MH-VFB-100 14 MH-VFB-160 28 MH-VFB-200 28.5 MH-VFB-250 36
35 56
G
19 21 21
65.5
98.5
106 125
80
53.8 120
NOTE: Material is Hardenable 18NiCrMo5.
USER MACHINED BOLT POCKET DIMENSIONS
USER MACHINED BOLT POCKET DIMENSIONS
D
USER MACHINED BOLT POCKET DIMENSIONS
D
C
D
A
C
A
C
A
G
B
G
B
G
B
E
1.5 X 60 SERRATION
USER MACHINED BOLT POCKET DIMENSIONS
E
F
1.5 X 60 SERRATION
F
E
1.5 X 60 SERRATION
D
F
ILM450018 REV C
C
ILM450018 REV C
A
ILM450018 REV C
MT-VFB for Serrated Base Jaws
G
B
Number
A
B
C D E
F
G
MT-VFB-66 28.5
20 25 F 40 45 50
8
34 55 80
4.5 6.6
24 35 60 74 90
7 9
E
MT-VFB-100 MT-VFB-160 MT-VFB-200 1.5 X 60 SERRATION
42 66 87
11 15 15 18
9 9
12 15 18
ILM450018 REV C
106 125
MT-VFB-250 108
11
NOTE: Material is Hardenable 18NiCrMo5.
Vise Fixture Keys
Fixture keys for use with the VZS vises.
H7
A
C
B
D
E BOLT SIZE
ILM450063 REV A
SOLD AS A PAIR
Vise Fixture Keys
Part Number
A
B
C D E
VA-12 VA-16 VA-18
12 16 18
8
20 22 22
3 4 4
M5 M6 M6
10 10
15
ACCESSORIES
MH-VZS JAW BLANKS SOLD AS A PAIR VZS Vise Jaws
MILLABLE AREA
B
E
C
G
F
H
A
D
MH-VZS Jaw Blanks
Number MH-VZS-70 MH-VZS-80 MH-VZS-90
A
B
C D E
F
G H
25 30 40
35.5 50.5 68.5 98.5
52 55 74
11.5
28 33 46 65
12 14 19 23
13 10 11 13
18 23 30 37
17 26 40
MH-VZS-125 50
100
NOTE: Material is Hardenable 18NiCrMo5.
MV-VZS V JAW BLANKS SOLD AS A PAIR
MIN/MAX
C
B
A
MV-VZS Jaw Blanks
Number MV-VZS-80 MV-VZS-90
A
B
C ØRange
18 23
30 38 50
55 74
10-35 14-45 20-60
MV-VZS-125 30.5
100
NOTE: Material is Hardenable 18NiCrMo5.
CLAMP RANGE ORIENTATION 2
C
CLAMP RANGE ORIENTATION 1
B
A
F
G H
E
D
ML-VZS Serrated Step Jaws SOLD AS A PAIR
ILM450062 REV A
ML-VZS Serrated Step Jaws Number ABCDEFGHL ML-VZS-70 24 28 32 12 8 6 69.5 75.5 52 ML-VZS-80 35 45.5 50 20.5 8 8 72 80 55 ML-VZS-90 29 56.5 68 22.5 8 12 78 90 74 ML-VZS-125 39.5 78.5 98 28.5 10 15 97 112 100
Mounted Vise ML-VZS-70-1 ML-VZS-70-2 ML-VZS-80
Clamping Range 1
Clamping Range 2
10 to 30 10 to 110 10 to 40 24 to 74 40 to 100 40 to 190
26 to 46 26 to 126 38 to 68 72 to 122 95 to 155 95 to 245
ML-VZS-90
NOTE: Material is Hardenable 18NiCrMo5.
ML-VZS-125-1 ML-VZS-125-2
18
ACCESSORIES
Inductive Proximity Sensors Digital flush mount inductive proximity sensors with stainless steel bodies and high ingress protection for use in any environment. Both pigtail and connector versions are available. Most options have the ability for IO-Link communication.
A
L
THREAD
ILM450055 REV A
A
L
A
L
1 4 3
1 4 3
+ Inductive Proximity Switches PNP
+
NPN
-
-
Ingress Protection
Part Number Thread A
L
Pins
IO-Link
Description
THREAD
29-7002-06 29-7002-07 29-7002-08 29-7002-09 29-7002-10 29-7002-11
M5 M5 M8 M8 M8 M8
25 25 32 32 32 32
2m
IP67 IP67
Yes Yes Yes No Yes Yes
0.8mm SENSING RANGE, PNP, 2m PIGTAIL 0.8mm SENSING RANGE, PNP, M8 MALE 2mm SENSING RANGE, PNP, 5m PIGTAIL 2mm SENSING RANGE, NPN, 5m PIGTAIL 2mm SENSING RANGE, PNP, M8 MALE 2mm SENSING RANGE, PNP, M12 MALE
0.2m 3
5m 5m
IP68, IP69K IP68, IP69K
L 0.2m 3 0.6m 3
ILM450055 REV A IP68, IP69K
A
IP68, IP69K
1 4 3
1 4 3
+
+
PNP
NPN
-
-
“S” Vise Inductive Proximity Sensor Mounting Kit The “S” mounting kit for VFB and VCV vises allows for the mounting of inductive proximity sensors. The kit replaces the existing cover plate and can be either ordered with the vise or installed at a later date. Sensor kits are available that include the mounting kit and two M5 or M8 proximity sensors. See IS6404 for installation information.
Mounting plates shown in orange.
ILM450056 REV B
“S” Vise Inductive Proximity Sensor Mounting Kit Complete Sensor Kit (Sensor + Mounting Hardware) Mounting Hardware Kit Part Number Included Sensor Part Number Sensor Thread S-VFB-100-M5 29-7002-07 S-VFB-100 M5 S-VFB-160-M5 S-VFB-160 S-VFB-200-M8 29-7002-11 S-VFB-200 M8 S-VFB-250-M8 S-VFB-250
17
MODEL NUMBER INDEX
Model No
Page Model No
Page Model No
Page Model No
Page
MH-VFB 66............................17 MH-VFB 100..........................17 MH-VFB 160..........................17 MH-VFB 200..........................17 MH-VFB 250..........................17 MH-VZS-70............................ 18 MH-VZS-80............................ 18 MH-VZS-90............................ 18 MH-VZS-125.......................... 18 ML-VZS-70............................. 18 ML-VZS-80............................. 18 ML-VZS-90............................. 18 ML-VZS-125........................... 18 MT-VFB 66.............................17
MT-VFB 100...........................17 MT-VFB 160...........................17 MT-VFB 200...........................17 MT-VFB 250...........................17 MV-VZS-80............................. 18 MV-VZS-90............................. 18 MV-VZS-125........................... 18 S-VFB-100............................. 13 S-VFB-160............................. 13 S-VFB-200............................. 13 S-VFB-250............................. 13 S-VFB-100-M5P. .................... 13 S-VFB-160-M5P. .................... 13 S-VFB-200-M5P. .................... 13
S-VFB-260-M5P. .................... 13 VA-12.................................... 17 VA-16.................................... 17 VA-18.................................... 17 VCV 100..................................9 VCV 160..................................9 VFB 66, Hydraulic.....................4 VFB 100, Hydraulic...................4 VFB 160, Hydraulic...................4 VFB 200, Hydraulic...................4 VFB 250, Hydraulic...................4 VFB 66, Pneumatic....................1 VFB 100, Pneumatic..................1 VFB 160, Pneumatic..................1
VFB 200, Pneumatic..................1 VFB 250, Pneumatic..................1 VZS-70.................................. 13 VZS-80.................................. 13 VZS-90.................................. 13 VZS-125................................ 13 65-0004-00........................... 17
18
SELF-CENTERING VISES REQUEST ADDITIONAL INFORMATION FROM WWW.VEKTEK.COM
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20Made with FlippingBook - Online Brochure Maker