Vektek Self-Centering Vises

HIGH PRESSURE SELF-CENTERING VISE

Hydraulic 250 bar Self-Centering Vise  Max operating pressure 250 bar.  High jaw repeatability: VCV 100: 0.01MM VCV 160: 0.02MM  Wedge and piston design.  Stroke range from 12 to 16MM.  Operating temperature range from 5C to 60C.  Hardened steel construction.  Hydraulic connections in the side or bottom.  Inductive sensors can be mounted for open, close, and part clamp detection. Requires the use of the S mounting kit.  The PC option adds the ability for pneumatic part presense sensing and blow off when manifold mounted by adding a pneumatic port in the top of the jaw.  The MB option adds the ability for pneumatic jaw position sensing for clamp and unclamp. Each state uses a seperate port, so they can be used individually to detect a single state, or together to also verify part clamping.

F

Specifications

Clamping Force (N)

Max Pressure (bars)

Jaw Stroke (mm)

Max Jaw Length (mm)

Close/ Open Time(s)**

Oil Consumption per Stroke Cycle (cm^3)

Vise Weight (kg)

F (mm)

Type

VCV 100 16 16,000 VCV 160 25 44,000

250 250

6 8

60 60

1

33

4.9

1.5

105

14.5

* The gripping force is the arithmetic sum of the individual forces at “F” distance at max pressure. ** Closing and opening times are purely the times that the base jaws are in motion. Valve switching, hose filling, PLC/CNC reactions, and other potential delays are not included and must be taken into consideration when determining cycle times.

ILM450024 REV B

PC AIR SUPPLY TO JAWS

PC AIR SUPPLY TO JAWS

MB VENTS UNDER JAW

VCV SENSING OPTIONS  The PC option adds the ability for pneumatic part presense sensing and blow off when manifold mounted by supplying compressed air to the jaws. This air can be routed through jaws and used to blow off the jaw faces before machining, or the port can be positioned to be covered by the part to increase air pressure and verify part presence.  The MB option adds the ability for pneumatic jaw position sensing for fully clamped and unclamped. Each state uses a seperate port, so they can be used individually to detect a single state, or together to also verify part clamping. Use max of 2 bar air pressure. Can be used with 50-8240-00 air sensing control kit.

MB VENTS UNDER JAW

MB AIR INPUT

PC AIR INPUT

MB AIR INPUT

PC AIR INPUT

ILM450054 REV A

ILM450054 REV A

MB PORT LOGIC

MB PORT LOGIC

PORT 4

MAX PSI

PORT 4

MAX PSI

<5PSI

<5PSI

PORT 6 MAX PSI

PORT 6 MAX PSI

<5PSI

<5PSI

FULLY EXPANDED

FULLY RETRACTED

FULLY EXPANDED

FULLY RETRACTED

11