Spray Machine Troubleshooting

NO

YES

Does the machine turn on?

NO

Are all electrical fittings plugged into the black box?

Place in upright position and bleed the system.

NO

Is the grey tap in the upright position?

Plug electrical fittings in.

YES

YES

Are all pipe connections fully secure? (Check the rubber seal is still in the filter)

Secure connections & replace rubber seal in filter if missing.

NO

NO

NO

Potential battery or charger fault.

Does it pick up water continuously?

Is the battery charged?

YES

YES

YES

Is it spraying from the nozzle as expected with the grey tap in the down position?

Check fuses and change if faulty.

Potential pump fault.

NO

Change or clean nozzle.