catalog

AOCH Series motor data

AOCH ELECTRIC MOTOR @ 60 Hz. DATA

NEMA Frame

Horse Power

Full Load Amperes

Service Factor

Thermal Overload

Enclosure Type

Model

Phase

Hz

Volts

RPM

NO NO NO NO NO NO NO NO NO

1.15 1.15 1.15 1.15 1.15

TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC

1800 1800 1800 1800 1800 1800 1800 1800 1800

60 60 60 60 60 60 60 60 60

56 56 56 56 56 56

1/2 1/2 1/2

AOCH-5,10,15,20 AOCH-5,10,15,20 AOCH-5,10,15,20 AOCH-25, AOCH-30 AOCH-25, AOCH-30 AOCH-25, AOCH-30 AOCH-35, AOCH-40 AOCH-35, AOCH-40 AOCH-35, AOCH-40

1 3 3 1 3 3 1 3 3

115/230 208-230/460 575 115/230 208-230/460 575 115/230 208-230/460 575

4.6/2.3 1.6/0.8 .8

1 1 1 3 3 3

8.6/4.3 3.4/1.7 1.5 28.0/14.0 7.6/3.8 3.3

1.0 1.0

184T 182T 182T

1.15 1.15

AOCH ELECTRIC MOTOR @ 50 Hz. DATA

Horse Power

NEMA Frame

7.2/3.6 1.6/1.0 12.4/6.2 3.4/1.8 25.0/12.5 7.6/4.9 Full Load Amperes

Service Factor

Thermal Overload

Enclosure Type

Model

Phase

Hz

Volts

RPM

NO NO NO NO NO NO

1.0 1.0 1.0 1.0 1.0 1.0

TEFC TEFC TEFC TEFC TEFC TEFC

1500 1500 1500 1500 1500 1500

50 50 50 50 50 50

56 56 56 56

AOCH-5,10,15,20 AOCH-5,10,15,20 AOCH-25, AOCH-30 AOCH-25, AOCH-30 AOCH-35,AOCH-40 AOCH-35, AOCH-40

1/2 1/2

1 3 1 3 1 3

110/220 230/400 110/220 230/400 110/220 230/400

1 1 3 3

184T 182T

ELECTRIC MOTOR NOTES:

6) Fan rotation is clockwise when facing the motor shaft. 7) The above motors contain factory lubricated shielded ball bear- ings; no additional lubrication is required.

1) All motors are NEMA, high efficiency 2) TEFC motors are available for all models.

3) Motor electrical ratings are an approximate guide and may vary between motor manufacturers. Consult ratings on motor data plate prior to installation and operation. 4) Explosion proof, high temperature, severe duty, chemical, IEC, Canadian Standards Association, and Underwriters Laboratory recognized motors are available upon request. 5) American Industrial reserves the right to enact changes to motor brand, type and ratings regarding horsepower, RPM,FLA,and service factor for standard products without notice. All specifc requirements will be honored without change.

8) Abbreviation Index TEFC................ Totally Enclosed, Fan Cooled X-PROOF......... Explosion Proof

CLASS I,DIV.1, GROUP D or CLASS II,DIV.2, GROUP F & G EXPLOSION PROOF MOTOR DATA

Horse Power

NEMA Frame

7.4/3.7 2.0/1.0 13.0/6.5 3.6/1.8 30.0/15.0 8.4/4.2 Full Load Amperes

Service Factor

Thermal Overload

X-PROOF X-PROOF X-PROOF X-PROOF X-PROOF X-PROOF Enclosure Type

Model

Phase

Hz

Volts

RPM

YES YES YES YES YES YES

1800 1800 1800 1800 1800 1800

60 60 60 60 60 60

1 3 1 3 1 3

56 56 56 56

AOCH-5,10,15,20 AOCH-5,10,15,20 AOCH-25, AOCH-30 AOCH-25, AOCH-30 AOCH-35, AOCH-40 AOCH-35, AOCH-40

1/2 1/2

115-208/230 208-230/460 115/230 208-230/460 115/230 208-230/460

1.0 1.0 1.0 1.0 1.0 1.0

1 1 3 3

215 182

NOTE: All of the AOCH Series explosion proof motors are available in 50hz upon request as a special

note: AIHTI reserves the right to make reasonable design changes without notice.

175

Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.

tel: 434-757-1800 355 American Industrial Drive LaCrosse, VA 23950

email: sales@aihti.com fax: 434-757-1810

Made with FlippingBook - professional solution for displaying marketing and sales documents online