4.5 Lights
Prevent serious injury or death. Electrical installations must be performed by qualified electricians. Installation must conform to all national, local, and provincial codes and standards. WARNING
1. Place light fixture into booth panel, center in opening, and bolt in place. 2. Install light fixture in panel from outside of booth as shown in drawing. 3. Caulk perimeter of light fixture lens frame with appropriate caulking.
4. The fixture is provided with an interlock switch that has a normally open contact, which opens when the fixture lens is removed from fixture. The switch is to be wired to disable spray equipment used in spray booth.
FIXTURE ENCLOSURE
LENS, FRAME GLASS, AND GASKET
LENS, FRAME FASTENER
FIXTURE FASTENER
CAULK SEAM
BOOTH WALL PANEL
5/16” UNC 18 HEX FLANGE NUT
MOUNTING
DETAIL CAUTION: WHEN TIGHTENING LENS FRAME FASTENERS, TIGHTEN USING HAND TOOLS ONLY. TIGHTEN UNTIL SIDES OF METAL LENS FRAME MAKES CONTACT WITH FIXTURE ENCLOSURE. OVER TIGHTENING WILL CAUSE LENS FRAME TO WARP AND WILL BREAK DOWN VAPOR SEAL OF LENS
PAINT SPRAY BOOTH WALL PANEL
5/16” UNC 18 HEX HEAD NUT
19