Exhaust piping, including the ARV (if used), should extend a minimum of 6 ft. above the highest point of building. There should be an access door just above exhaust unit.
4.12 Product Door
E
E
C C D D
C C D D
A A B B
A A B B
C C D D
C C D D
A A B B
A A B B
E
E
Side of door with 2 x 4 in. tube is the hinge side. Before installing door, verify both door channels and top door stop installed properly and squared. Verify dimension between channels and floor to door stop with door drawing. Install Left Door 1. Place spacers between door and floor. Door is manufactured to have a 1 in. clearance at bottom, 1/2 in. clearance on top and 1/2 in. clearance on sides. 2. Put hinges in place per dimension (E) on door drawing. Install screw in center of slots A and C on all hinges. Do not tighten screws at this time. 3. Adjust the door in all directions. Assure the door closes completely, then tighten screws. 4. Install screws in center of slots B and D. 5. Remove spacers. 6. Repeat steps 1-5 to install right door.