910127_900 Spec Sheet

Technical specifications

900

3 Phase, 380, 440 and 480 VAC

Input voltage options

410, 354, and 324 A respectively

Currency draw

60 Hz (50 Hz available)

Frequency

Internal transformer

Isolation transformer

> 99%

Power factor

< 3% THD; IEEE 519 Compliant

Harmonic distortion

Manual; Remote Operation System (ROS); DCOM Driver for LabVIEW; C++ and Visual Basic; CAN

Multiple user interfaces

< 65mArms and 130mArms, respectively

Current ripple - indepdendent & parallel mode

< 15 Arms

Current ripple - max ripple from load

32 - 95°F (0 - 35°C)

Operating environment - temperature

5-90% non-condensing

Operating environment - humidity

6,063 lbs. (2,750 kg)

Weight

73 x 37 x 76.54 in. (185 x 94 x 194 cm)

Dimensions (L x W x H)

Operating range Configuration

Voltage (Vdc)

Current (Adc)

Power (kW)

+8 to +750

-500 to +500

-250 to +250

Independent

+751 to +825

-400 to +400

-225 to +225

Optional range

+826 to +900

-300 to +300

-200 to +200

+8 to +750

-1000 to +1000

-250 to +250

Parallel

+751 to +825

-800 to +800

-225 to +225

Optional range

+826 to +900

-600 to +600

-200 to +200

Accuracy & resolution Measurement

Accuracy (±)

Resolution

250mV or 0.15% of the output voltage

50mV

Voltage

250mA or 0.25% of the reading

40mA

Current independent (2 channels)

350mA or 0.35% of the reading

80mA

Current external parallel (1 channels)

Webasto Thermo & Comfort North America, Inc. 15083 North Road Fenton, Michigan 48430 USA Toll Free: 800-860-7866 Phone: 810-593-6000 evtestsystems.com

PTS Brochure

evtestsystems.com

Made with FlippingBook Online newsletter