4.10 T ubeaxial F an
^ WARNING
Fan assembly is heavy. Fan assembly weight is approximately 50 - 200 lbs., depending on model. Use and adequate lifting device to install fan assembly.
^ WARNING
Prevent serious injury or death. Electrical installations must be performed by qualified electricians. Installation must conform to all national, local, and provincial codes and standards.
The fan and motor assembly will bolt to exhaust roof panel.
4.11 E xhaust D uct I nstallation
If equipped with optional exhaust ductwork, it is recommended to have this professionally installed. To assemble the ductwork: 1. Bolt pipe with connecting ring to the exhaust fan. 2. Remaining ductwork is crimped on one end to interlock with the next section. 3. Your ARV(automatic damper) will be mounted on top. 4. Storm collar will attach to duct above flashing to make it weatherproof. Where more than 25 ft. of piping is required, static pressure (resistance) is increased and the air flow may be hindered when using the standard exhaust unit recommended for use with the booth. Where a piping arrangement of an unusual nature is necessary or where two or more elbows are used, a similar condition may exist. Therefore, if either of these situations arises, contact the RTT for recommendations. Exhaust piping, including the canopy (if used), should extend a minimum of 6’ ft. above the highest point of building. There should be an access door just above exhaust unit and another just below each elbow.
Made with FlippingBook - professional solution for displaying marketing and sales documents online