Practical Pointers | Fives North American

NOZZLE MIX SYSTEMS

air

manometer

16 osi

combustion chamber

16 osi - (-2 osi) = 18 osi burner capacity

*

EFFECT OF PRESSURE OR SUCTION IN COMBUSTION CHAMBER ON BURNER CAPACITY WITH NOZZLE-MIX BURNERS If there is a 2 osi suction in the chamber, this 2 osi is added to the 16 osi air pressure and burner capacity should be based on 18 osi. If there is a 2 osi positive pressure, it should be subtracted from the 16 osi air pressure and the capacity should be based on 14 osi.

* See page 9

37

Made with FlippingBook - Online catalogs