Beall - Operations Manual - Petroleum Tank Trailers

75 GENERAL MAINTENANCE

PERIODIC DOT INSPECTION FMCSA Certification:

CERTIFICATION THIS VEHICLE HAS PASSED AN INSPECTION IN ACCORDANCE WITH 49 CFR PART 396 AND MUST BE REINSPECTED DURING OR BEFORE THE SAME CALENDAR MONTH ONE YEAR AFTER THE DATE SHOWN BELOW. ADDRESS FMCSA PERIODIC INSPECTION JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 11 12 13 14 15 16

When new this vehicle passed an inspection in accordance with 49 CFR, part 396 and shall be re-inspected during or before the same calendar month on year after the date marked on the of the inspection report must be retained by the motor carrier.

LOCATION OF RECORDS:

COMPANY :

ADDRESS :

VEHICLE ID (IF REQUIRED):

COMPRESSOR

Recommended compressor governor cut-in pressure must be 105 psi for trailers and chassis manufactured after October 8, 1992 to release parking brakes properly.

ELECTRICAL

electrical wiring and testing procedures when inspecting, testing, or maintaining the wiring harness, lights, and accessories.

Keep all wiring properly maintained.

1. Lubricate connections with dielectric grease. 2. Lubricate 7-way and other plug connections with dielectric grease. 3. Do not probe wires through the insulation, test at wire ends. 4. Keep all connections within a protective junction box. 5. ABS sensor wires must be inspected and maintained for proper operation. taken when maintaining these connections. 7. Work lights and misc electrical accessories need to be maintained and the wiring protected. cabinets that may contain electrical components and wiring. 9. Protect all wiring harnesses and wiring in conduit when using a drill, saw, heat, or performing weld repairs.

www.

.com

Made with FlippingBook Annual report maker