catalog PowerSafe

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - BACKSHELLS

TV NSA Backhells

These backshells ensure the shielding by clamping the braid with a screwing system. The free inner ring avoids twisting of the braid during screwing (double conus style). See part how to order page 19

Shell size

A Thread Metric

B max

Ø C max

Ø D max

Ø E max

Ø G max

13

M18 x 1.0-6H 26

12.7

28.1 21.2 22.6

15

M22 x 1.0-6H 29

14.8

31.1 25.1 25.8

17

M25 x 1.0-6H 32

17.9

34.1 28.1 29.0

21

M31 x 1.0-6H 39

23.1

41.1 34.1 35.2

23

M34 x 1.0-6H 42

26.2

44.1 36.9 38.4

25

M37 x 1.0-6H

45

28.8

49.1 39.9 41.5

Use Straight Shrink Boots 202K121-12 (size 13), 202K132-12 (size 15 and 17), 202K153-12 (size 21, 23 and 25) and S1255 Adhe - sive TV NSA Installation instructions

Figure 1

Figure 2

2

Figure 3

Figure 4

Figure 5

VG95319 Backshells These backshells are suitable for Power Safe connectors and ensure the shielding by clamping the braid with a screwing system (single conus style). 4. Install the braid as shown on figures 3 and 4: Release the braid and cover the backshell (a) and the connector’s shell. Slide the first ring (b) over the braid. Fold back the braid on the ring (b) and slide the second ring (c) over the braid and the first ring (b). Screw the last ring (d) at the rear of the backshell. If necessary, fix the extra braid on the outer jacket of the cable. If this installation (double folding of the braid) is not possible, refer to figure 5: Slide the first ring (b). Release the braid and cover the backshell (a) and the connector’s shell. Cut the braid as shown. Slide the second ring (c) over the braid and the first ring (b). Screw the last ring at the rear of the backshell. 5. Then, Install the heat-shrink moulded piece. 1. Prepare the cable for termination process and slide the items onto the cable in the order shown on figure 1. 2. Screw the backshell at the rear of the connector. The best performance in time of the system « connector + rear accessory » consists in applying the torque value to screw then unscrew, to apply the torque value & screw a second time, then to unscrew and finally screw the torque value a third time. 3. Fold back the braid on the outer jacket and fix it (figure 2)

Backshell VG Standard

Micro Clamping Band

Standard Clamping Band

Tool for Micro Band

Tool for Standard Band

Shrink boot

Adhesive

or

Shell size

13 15 17 21 23 25

VG95319-1011G012A

VG95343T06B001A

VG95319-1011G004A

895693

VG95343T06B003A

VG95319-1011G005A

VG95343T15A001

072952

809985

809952

VG95319-1011G008A

VG95343T06B004A

VG95319-1011G009A

VG95343T06B005A

895700

VG95319-1011G010A VG95343T06C010A Use Straight Shrink Boots 202K121-12 (size 13), 202K132-12 (size 15 and 17), 202K153-12 (size 21, 23 and 25) and S1255 Adhesive

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex