catalog PowerSafe

Amphenol Socapex │ POWERSAFE

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

1

OUR COMPANY

Proven excellence in interconnect solutions - Since 1947 , Amphenol Socapex has prescribed, designed and manufactured reliable and innovative interconnection solutions for harsh environments, specializing in standard and customized electrical and fiber optic connectors, contacts, accessories and cabling solutions. - Located in the Mont Blanc region of France and Pune in India, Amphenol Socapex serve customers in over 100 countries around the world. - Amphenol Socapex is part of the leading supplier of interconnect systems Amphenol. € 1400+ employees 142 M€ Net Sales 2023 70% Export - 30% France Thyez , France Pune, India

Our expertise has no boundaries Integrated Production in France & India - 24 000 m 2 manufacturing capacity on 2 sites - Design and manufacturing centers in France and India - State-of-the-art manufacturing technology

Our markets

Industry

Space

Defense

Commercial Aerospace

TECHNOLOGIES & INNOVATION

High-Speed Expertise

Engineering Laboratory

Materials Expertise

Eco-responsibility

Product testing and qualification expertise in many fields: - Environmental, mechanical, electrical, chemical, climatic skills - RF and fiber optics expertise

Focus on materials expertise and manufacturing techniques to produce faster, smaller and stronger products - Advanced technology research and development: polymers, metals, platings, resins ... - Cutting edge characterizations of interconnects: Radio Frequency, partial discharges ... - 3D CAD mechanical software, simulation & analysis

Sustainable environment approach, with pro-active management of regulations (REACH / RoHS / Conflict minerals...) - New materials development, plating, and suitable processes - Recycling and rational resources consumption

Strong expertise in high-speed signals - 3D EM simulation software & EM models - Time Domain and frequency domain

Our workshops

Our workshops located in France & India provide consistent quality adapted to your volume requirements. Automation & Tooling : Tools for our different activities : molding, machining, assembly

Molding : Solid expertise in thermoplastic elastomer and thermoset molding Machining : Manufacturing of cylindrical shells and rectangular shells Screw Machining : Manufacturing of electrical contacts Plating : Plating with cadmium, nickel, electroless nickel, silver, black zinc nickel, gold Assembly : Connector and harness assembly (electrical & optical)

Our certifications

Our memberships

Member of CMG (Connecting Manufacturing Group) Consortium

Product certifications : MIL-DTL38999, EN3645, EN3155, VG (VG95328, VG95319, VG96944, VG95218, VG96949)

Certified Management System

Certified Management System

Certified Management System

Certified Management System

CUSTOMER EXPERIENCE

We have a strong reputation for helping customers solve their toughest challenges. This approach of serving your needs is ingrained in our company – from our sales team to our product development engineers.

A partner you can trust

On Time Delivery Performance

Compliance management

Customer Proximity

Design Expertise

Quality Commitment

Buy our solutions

You can access our solutions through our global network of sales offices or through our distributors.

Field Sales Team : 10 in France 15 in Europe 100+ in North America and rest of the world. 5 Business Development Managers supporting local sales force Europe, North America and the rest of the world

Technical Advisement & Multilingual Customer Service : 20 people

Worldwide Distribution Network : Our range of circular connectors, contacts, fiber optic connectors, PCB connectors and accessories are available thru our extensive distribution network. It includes qualified distributors (QPL approved) for assembling MIL-DTL-38999 & derivatives and PT/451 (VG95328) connectors.

Check our product inventory

Product Selectors & 3D Files

OUR HISTORY

1947

Early 1960’s

1973

1975

1956-57

Séries 127/HE8

Séries PT/451

New factory in Thyez (74) France with 250 people, 13 000m 2

Production of 38999 connectors

- Socapex creation in Suresnes, France - 1 st radio connector

- 1 st board level connectors: HE8 - 1 st “licence Bendix” manufactured connectors - SL Series

- Manufacturing unit in Cluses (74), France - Thomson-CSF becomes primary shareholder

1986

2004

2005

2010’s

1995-96

Amphenol Socapex

LuxBeam TM

HDAS

New factory in Pune, India

LuxBeam TM

and

HDAS

- Expanded Beam connector CTOS launch - Headquarters transferred to Thyez

Amphenol becomes primary shareholder

RJ Field launch, “Award Electronica”

launch

2014-2017

2022

Today & tomorrow

2019

New technologies : - Investment in automation & technical expertise

High Speed Contacts

Cable Assembly

Amphenol SOCAPEX joins the “ Convention des Entreprises pour le Climat ” . - Our goal: to accelerate our transition to a more sustainable operation.

Harness in the box solution launch

Increased manufacturing capacity with 2 nd building in Pune, India

New workshops : - Cable Assembly & Contact Manufacturing workshop

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - GENERAL CHARACTERISTICS

Power connector qualified VG96944 and designed for user safety

Description PowerSafe connectors are derived from MIL-DTL-38999 Series III connectors and dedicated to high power supply in harsh environments. These connectors provide the user with, the highest user safety, shielding effectiveness & environmental performances. PowerSafe connectors follow the European standard for power equipment DIN EN 61984 (former VDE 0627).

Markets

C5ISR - Battlefield Communication Ground Vehicles Military Avionics Missile Avionics Navy Harsh Industrial Environment

Applications

Power connectors deployed on the field (drums) Electrical power generator

Military Aerospace

Ground Vehicle

C5ISR

Navy

Industrial

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

6

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - GENERAL CHARACTERISTICS

Power connector qualified VG96944 and designed for user safety

Main features

TWO INSERTS TYPES WITH DIFFERENT CHARACTERISTICS

HIGH ROBUSTNESS AND EXCELLENT ENVIRONMENTAL PERFORMANCES . SEVERAL MATERIALS & PLATING - Aluminum (Olive drab Cadmium, Nickel, Black Zinc Nickel, Tin Zinc platings) - Marine Bronze - Stainless steel (Passivated, Nickel plated upon request) EMI/RFI PROTECTION : Shell to shell bottoming and grounding fingers on the plug shell ACCESSORIES: - Caps: compatible with MIL-DTL-38999 Series III caps. - Backshells: compatible with AS85049 backshells for MIL- DTL-38999 Series III connectors, VG95319-1011G, as well as TV35 & TVNSA backshells. Same panel drilling as standard MIL-DTL-38999 Series III connectors.

● “E” inserts – up to 200°C & CTI (Comperative Tracking Index) <100 Available in Amphenol Proprietary designations only ● “V” inserts – VG96944 compliant – up to 150°C & CTI between 175 & 400 (Material Group IIIa) Available in VG designations & Amphenol Proprietary ones FIRST MATE/LAST BREAK : one earth contact directly linked to the shell, stays in place even in case of overheats. LAST MATE/FIRST BREAK: one pilot contact with a breaking capacity (brings the information to a relay to turn on/off the power). These features protects the user even if the connectors are mated or unmated. Amphenol recommends to connect / disconnect connector when unloaded. IP28 WHEN UNMATED, IP68 WHEN MATED

Added benefits

- Power Safe is compliant with IP2X Electrical Safety standard , which guarantees touch-proof protection of live parts. - Qualified according the most stringent standard VG96944 (applicable to Aluminum with Olive Drab Cadmium or Tin Zinc finish and Marine Bronze versions only). - Safety use design following DIN EN-61984 (former VDE 0627) .

Concept

1

Coupling nut Quick coupling thread Anti-decoupling device Plug shell Grounding spring Grommet Receptacle shell Contact retention clips Phase and neutral socket contact

Pilot socket contact Protective socket contact Phase and neutral pin contact Pilot pin contact Protective pin contact Interfacial seal Socket insert Pin insert

1 2 3 4 5 6 7 8

10

7

2

16

15

11

8

4

12

9

8

13 14 15 16 17

12

6

6

17

10

13

11

14

3

9

5

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

7

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - LAYOUTS & ELECTRICAL CHARACTERISTICS

Amphenol Power Safe range offers 6 contact arrangements to fit all your power needs, with single-phase & three- phase layouts, and a choice of 2 insert materials for each layout depending on the need : → V inserts : developped according to VG96944 standard with a material less impacted by the disconnection under load. Able to withstand a maximum temperature of 150°C & have a CTI between 175 & 400 (Material Group IIIa) → E inserts : using the same material than our 38999 series connectors and able to whistand a temperature up to 200°C

Single-Phase Layouts

13-V4 13-E4

15-V4 15-E4

21-V4 21-E4

23-V4 23-E4

V insert E insert

Pilot contact (P)

1 Size 20 2 Size 16 1 Size 16

1 Size 16 2 Size 12 1 Size 12

1 Size 16 2 Size 6 1 Size 6

1 Size 16 2 Size 4 1 Size 4

Phase & neutral (N & L)

Protective contact

Pilot contact - P

Phase, Neutral and Protective contact - N, L &

Contact Arrangements

Test voltage AC *

Operating Voltage AC or DC

Operating Voltage AC or DC

Contact rating

Contact rating

13-V4 / 13-E4 15-V4 / 15-E4 21-V4 / 21-E4 23-V4 / 23-E4

0,5 A 0,5 A 0,5 A 0,5 A

60 V 60 V 60 V 60 V

16 A 25 A 63 A

250 V 250 V 500 V 500 V

1500 V 1500 V 2500 V 2500 V

100 A

Three-Phase Layouts

17-V6 17-E6

25-V6 25-E6

V insert E insert

Pilot contact

1 Size 16 4 Size 12 1 Size 12

1 Size 16 4 Size 6 1 Size 6

Phase & neutral Protective contact

Pilot contact - P

Phase, Neutral and Protective contact - N, L1, L2, L3 &

Contact Arrangements

Test voltage AC *

Operating Voltage AC or DC

Operating Voltage AC or DC

Contact rating

Contact rating

17-V6 / 17-E6 25-V6 / 25-E6

0,5 A

60 V

25 A

500 V

2500 V

0,5 A

60 V

63 A

250 V

1500 V

*Note : Test voltage in mated condition for Phase, Protective and Neutral pin & socket contacts, and Pilot pin contacts. Test voltage in unmated condition for Pilot socket contact only

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

8

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - CHARACTERISTICS

Environmental characteristics

Connectors with Proprietary inserts E

Connectors with VG96944 compliants inserts V

-65 to +175°C (Olive drab cadmium, Black zinc nickel plating) -65 to + 200°C (Nickel plating, Marine Bronze, Stainless steel) 48h for Nickel plated Aluminum 500h for Olive drab cadmium, Black zinc nickel, Marine Bronze and Stainless steel IP28: - Finger test for socket contacts and socket inserts - Pressure water tight (48h, under 2m water)

Temperature

-65 to +150°C (all materials and platings)

Test level 2 : 5% NaCl. 2h salt spray exposure and 22h storage in humid air repeated during 5 cycles

Salt spray exposure

IP28: - Finger test for socket contacts and socket inserts - Pressure water tight (48h, under 2m water)

Sealing

Mechanical characteristics

Connectors with Proprietary inserts E

Connectors with VG96944 compliants inserts V

Durability

500 mating cycles

500 mating cycles

Shocks

-

Half-sine, 500 m/s 2 , 11 ms

Sine vibrations 60g from -55 +175°C (Olive drab cadmium) / + 200°C (Nickel)

-

Random vibra- tions

Per EIA-364-28

Per VG95319-2 (Spectrum 5 Hz to 500 Hz)

Thermoplastic insert Silicone rubber grommet and interfacial seal

Thermoplastic insert Silicone rubber grommet and interfacial seal

Insert material

Insulator material Comparative Tracking Index

<100V

<400V

Crimp, removable contacts Gold plating for pilot contact and silver plating for protective, phase and neutral contacts

Crimp, removable contacts Gold plating for pilot contact and silver plating for protective, phase and neutral contacts

Contacts

Protective contact Resistance

≤100 mΩ

≤100 mΩ

Contact retention force

Contact Size

20

16

12

6

4

Maximum load (N)

67

111

111

111

150

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

9

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - OVERALL DIMENSIONS - RECEPTACLES

Square flange receptacle

See part how to order page 22 AMPHENOL VG TVP00RW***

VG96944-04A**A

TVP00ZN*** TVP00TZ*** TVPS00RF*** TVPS00RB*** TVPS00RK***

VG96944-04A**J

VG96944-04A**B

B thread Class 2A (inches)

N +0.13 0 (mm) 22.99 25.49 25.49 27.49 27.49 27.49

L Max (mm)

M Max (mm)

S ±0.3 (mm)

T ±0.2 (mm)

TT ±0.2 (mm)

R1 (mm) 23.01 24.61 26.97 31.75 34.93 38.10

R2 (mm) 20.62 23.01 24.61 29.36 31.75 34.93

V thread (metric) M18x1-6g M22x1-6g M25x1-6g M31x1-6g M34x1-6g M37x1-6g

Shell size

13 15 17 21 23 25

.875

15.5 15.5 15.6 17.5 20.7 20.7

20.9 23.3 23.4 24.6 24.6 24.6

28.6 31.0 33.3 39.7 42.9 46.0

3.25 3.25 3.25 3.25 3.91 3.91

4.93 4.39 4.93 4.93 4.93 6.15

1.0000 1.1875 1.3750 1.5000

1.625

Jam nut receptacle

See part how to order page 22 AMPHENOL VG TV07RW** VG96944-04B**A

TV07ZN** TV07TZ** TVS07RF** TVS07RB** TVS07RK**

VG96944-04B**J

VG96944-04B**B

A +0.1 -0.15 (mm) 23.82 26.97 30.15 36.50 39.67 42.85

H Hex 0 -0.1 (mm)

B thread Class 2A (inches)

C Max (mm)

K Max (mm)

P Max (mm)

S +/-0.4 (mm)

Hex nut max torque (N.m)

T (mm)

V thread (metric)

Shell size

13 15 17 21 23 25

.875

38.4 41.6 44.8 25.7 55.9 59.0

22.5 25.0 25.0 27.0 27.0 27.0

13.7 14.1 14.1 18.5 18.5 18.5

30 34 36 46 46 50

34.9 38.1 41.3 49.2 52.4 55.6

25.20 - 25.50 M18x1-6g

20

1.0000 1.1875 1.3750 1.5000

28.30 - 28.60 31.80 - 31.95 37.97 - 37.80 41.00 - 41.30 44.20 - 44.5

M22x1-6g M25x1-6g M31x1-6g M34x1-6g M37x1-6g

30

40

1.625

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

10

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - OVERALL DIMENSIONS - PLUG

Straight plug

See part how to order page 22 AMPHENOL MILITARY TV06RW** VG96944-04C**A

TV06ZN** TV06TZ** TVS06RF** TVS06RB** TVS06RK**

VG96944-04C**J

VG96944-04C**B

Conforms to CECC 75.201.002 (coupling nut for arctic gloves)

B thread Class 2B (inches)

Q Max (mm)

F Max (mm)

D (mm)

V thread (metric)

Shell size

13 15 17 21 23 25

.875

29.4 32.5 35.7 38.5 44.9 48.0

35.5 38.0 38.0 44.4 46.0 46.0

15.01 17.51 17.51 19.51 19.51 19.51

M18x1-6g M22x1-6g M25x1-6g M31x1-6g M34x1-6g M37x1-6g

1.0000 1.1875 1.3750 1.5000

1.625

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

11

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - JAM NUT REDUCED FLANGE RECEPTACLE

Reduced flange receptacle are derived from 38999 series III Jam nut receptacles and dedicated for applications where size & weight are criticals, offering un smaller footprint and higher contact density

Main features

With Castle nut

- For Jam nut receptacle (TV07/TVS07). - Higher density on panel: 41% average footprint surface reduction. - Lighter: 20% average lighter than standard 38999 - Mates with standard Power Safe plug and caps. - Matches the Power Safe performances. - Improved design of the o’ring groove allowing the o’ring to stay in place.

MATED PAIR

RECEPTACLE FRONT FACE

Standard TV*07***

Jam nut Reduced flange TV*07***F312

Footprint savings Average 41% footprint reduction:

Reduced flange F312

PowerSafe Reduced flange (F312) ØB MAX (mm)

Standard

Standard PowerSafe ØA MAX (mm)

Size

Ø Reduction

13 15 17 21 23 25

38.4 41.6 44.8 52.7 55.9

28.1 32.1 36.1 41.1 44.1 48.1

46% 40% 35% 39% 38% 34%

59

All others dimensions remains the same in standard or reduced flange (lengths, threads, etc.). See page 10 for all other Jam nut receptacle dimensions Panel hole dimensions

ØG +0.1 0

H +0.1 0 22.3 25.5 30.3 35.1 38.3 41.5

E recommended

Size

13 15 17 21 23 25

31.4 34.5 37.7 43.7 46.9 51.0

23 27 31 36 39 43

Tooling

Specific tool for castle nut

Size

Tool reference

13 15 17 21 23 25

809683 809684 809685 809687 809688 809689

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

12

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - KEYWAY & PANEL HOLE DIMENSIONS

A plug with a given rotation letter will mate with a receptacle with the same rotation letter. The angles for a given connector are the same whether it contains pins or sockets. Minor keys stay fixed, master key rotates. Keyway identification letter is (Blank) for Normal, A, B, C or D . Keyway polarization

RECEPTACLE (front face shown)

PLUG (front face shown)

Position of the major key

Size

NORMAL BLANK

A

B

C

D

13 15 17 21 23 25

100

80

68

132

120

100

79

66

134

121

100

82

70

130

118

100

82

70

130

118

100

85

74

126

115

100

85

74

126

115

Panel hole dimensions

Square flange receptacle rear panel mounting

Square flange receptacle front panel mounting

Jam nut receptacle rear panel mounting Ø C

R 1

R 1 R 2

4 Ø W

4 Ø W

B

G

V

V

* Maximum panel thickness for back panel mounting: 5.8mm for size 13 to 17, 5mm for size 21 to 25.

ØC +0.25 0 (mm)

B 0

ØW ± 0.13 (mm)

V Mini (mm)

ØA Min (mm)

ØAA Min (mm)

G Mini (mm)

R 1 (mm)

R 2 (mm)

Shell size

-0.25 (mm)

13 15 17 21 23 25

23.01

20.62

30.20

23.42

19.05

3.25

36.00

25.65

24.26

24.61

23.01

33.30

26.59

23.01

3.25

39.60

28.83

27.56

26.97

24.61

36.50

30.96

25.81

3.25

43.30

32.01

30.73

31.75

29.36

42.50

36.12

32.16

3.25

50.60

38.35

37.08

34.93

31.75

45.70

39.29

34.93

3.81

54.20

41.53

40.26

38.10

34.93

48.80

42.47

37.69

3.81

59.70

44.70

43.43

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

13

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - BACKSHELLS

TV NSA Backhells

These backshells ensure the shielding by clamping the braid with a screwing system. The free inner ring avoids twisting of the braid during screwing (double conus style). See part how to order page 23

Shell size

A Thread Metric

B max

Ø C max

Ø D max

Ø E max

Ø G max

13

M18 x 1.0-6H 26

12.7

28.1 21.2 22.6

15

M22 x 1.0-6H 29

14.8

31.1 25.1 25.8

17

M25 x 1.0-6H 32

17.9

34.1 28.1 29.0

21

M31 x 1.0-6H 39

23.1

41.1 34.1 35.2

23

M34 x 1.0-6H 42

26.2

44.1 36.9 38.4

25

M37 x 1.0-6H 45

28.8

49.1 39.9 41.5

Use Straight Shrink Boots 202K121-12 (size 13), 202K132-12 (size 15 and 17), 202K153-12 (size 21, 23 and 25) and S1255 Adhe - sive TV NSA Installation instructions

Figure 1

Figure 2

2

Figure 3

Figure 4

Figure 5

VG95319 Backshells These backshells are suitable for Power Safe connectors and ensure the shielding by clamping the braid with a screwing system (single conus style). 4. Install the braid as shown on figures 3 and 4: Release the braid and cover the backshell (a) and the connector’s shell. Slide the first ring (b) over the braid. Fold back the braid on the ring (b) and slide the second ring (c) over the braid and the first ring (b). Screw the last ring (d) at the rear of the backshell. If necessary, fix the extra braid on the outer jacket of the cable. If this installation (double folding of the braid) is not possible, refer to figure 5: Slide the first ring (b). Release the braid and cover the backshell (a) and the connector’s shell. Cut the braid as shown. Slide the second ring (c) over the braid and the first ring (b). Screw the last ring at the rear of the backshell. 5. Then, Install the heat-shrink moulded piece. 1. Prepare the cable for termination process and slide the items onto the cable in the order shown on figure 1. 2. Screw the backshell at the rear of the connector. The best performance in time of the system « connector + rear accessory » consists in applying the torque value to screw then unscrew, to apply the torque value & screw a second time, then to unscrew and finally screw the torque value a third time. 3. Fold back the braid on the outer jacket and fix it (figure 2)

Backshell VG Standard

Micro Clamping Band

Standard Clamping Band

Tool for Micro Band

Tool for Standard Band

Shrink boot

Adhesive

or

Shell size

13 15 17 21 23 25

VG95319-1011G012A

VG95343T06B001A

VG95319-1011G004A

895693

VG95343T06B003A

VG95319-1011G005A

VG95343T15A001

072952

809985

809952

VG95319-1011G008A

VG95343T06B004A

VG95319-1011G009A

VG95343T06B005A

895700

VG95319-1011G010A VG95343T06C010A Use Straight Shrink Boots 202K121-12 (size 13), 202K132-12 (size 15 and 17), 202K153-12 (size 21, 23 and 25) and S1255 Adhesive

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

14

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - BACKSHELLS

TV35 and TVB35 band backshells provide a full 360° shield termination with a quick, easy and cost effective cabling process. They are available with different cabling chamber lengths and exit diameters. The use of replaceable bands facilitates future maintenance or reparability. Sealing is ensured by straight or right angled heat shrink moulded piece at the rear of backshell. TV35 Backshells

See part how to order page 23

Shell size

B Thread Metric

Ø A max

Ø C

Ø D

13

M18 x 1.0-6H

31.80

25.00

13.80

15

M22 x 1.0-6H

35.00

28.00

16.30

17

M25 x 1.0-6H

38.10

30.80

20.10

21

M31 x 1.0-6H

44.30

36.90

26.00

23

M34 x 1.0-6H

47.20

39.80

29.28

25

M37 x 1.0-6H

50.00

43.00

32.45

Cabling chamber length F +/-0.1 mm

Z rear side diameter coding

Shell size

E max mm

08

10

12

14

16

20

24

28

32

36

.

.

. . . .

.

.

.

.

36 46 56 36 46 56 36 46 51 56 36 46 56 36 46 56 36 46 56

10 20 30 10 20 30 10 20 25 30 10 20 30 10 20 30 10 20 30

13

. .

.

. . . . .

.

.

15

. .

. . .

. .

.

17

. .

.

. . .

.

.

21

.

. . .

.

23

.

. . .

.

25

.

Z Coding

08

10

12

14 11

16

20

24 19

28

32

36

ØZ

6.30

7.90

9.40

12.60

15.80

22.10

25.30

28.80

ØS MIN MAX

9.40 9.50

11.10 11.2 17.10 14.50

14.10 14.30 0

14.10 14.30 18.70 16.10

15.70 15.90 20.30 17.70

18.90 19.10 23.50 20.90

22 22.20 26.70 23.10

25.20 25.40 29.80 26.20

28.40 28.60

31.50 31.80 36.20 32.60

ØD1 ±0,1 ØD2 ±0,1

14.00 11.40

17.10 14.50

33

29.40

Use Straight Shrink Boots 202K121-12 (size 13), 202K132-12 (size 15 and 17), 202K153-12 (size 21, 23 and 25) and S1255 Adhesive.

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

15

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - PROTECTIVE CAPS

Main features - Available for Plugs, Jam nut and Square receptacles - IP 68 (permanent sealing) - Protection against dust, water and moisture - EMI function - Nylon cord, stainless steel rope or metallic chain

Overall dimensions See part how to order page 24

FOR SQUARE FANGE RECEPTACLE

FOR JAM NUT RECEPTACLE

FOR PLUGS

BF

BEC

BER

BFRO

A thread .1P-.3L-TS Class 2A (External) Class 2B (Internal) (inches)

Shell size

ØB Max (After Knurling)

ØC Min

ØN Max

13 15 17 21 23 25

.875

25.75 28.90 33.80 38.60 41.70 44.90

25.15 29.92 32.00 38.25 42.62 44.45

24.30 27.40 30.60 36.40 39.70 42.80

1.0000 1.1875 1.3750 1.5000

1.625

Nylon cord, Chain and Stainless Steel Rope length

Cap type

Attachement length

BEC/BER for receptacle

127 (+13 / -7)

BF/BFRO for plug

160±5

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

16

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - DUMMY RECEPTACLES

- Dedicated to Power Safe - Universal coding : Compatible with all Keyway polarizations - Can be used as a backshell tightening tool - Same dimensions and Panel holes than a standard Square Flange Receptacle (see page 10).

See part how to order page 24

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

17

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - CONTACTS & TOOLING

Contacts

Crimping tools

Insertion tools

Removal tools

dia over insulator

Proprietary Part Number

Contact type

Section mm²

Size

AWG

Metallic

Metallic

Selector position

Plastic (Color)

Plastic (Color)

Tools

Positioner

Straight type

Angle type

Straight type

Angle type

Pin

Socket

Min Max

20 22 24

0,61 0,38 0,24 1,94 1,23 0,96 0,61 1,23 0,96 0,61

3 2 1 6 6 5 4 6 5 4

M81969/14-10 (red / orange) M81969/14-03 (blue / white)

M81969/14-10 (red / orange) M81969/14-03 (blue / white)

Pilot

20 600665 600892

1,02 2,11

809817 M81969/8-05

809847 M81969/8-06

13-V4 13-E4

Phase Neutral

600666 600676 14 16 18 20 600667 600677

M22520/1-01 M22520/1-04

16

1,65 2,77

809816 M81969/8-07

809846 M81969/8-08

Protective

/

/

16 18 20

M81969/14-03 (blue / white) M81969/14-04 (yellow / white)

M81969/14-03 (blue / white) M81969/14-04 (yellow / white)

Pilot

16 600660 600894

1,65 2,77

809816 M81969/8-07

809846 M81969/8-08

15-V4 15-E4

Phase Neutral

600661 600671

M22520/1-01 M22520/1-04

12 14

2,98 1,94

8 7

12

2,46 3,61

/

M81969/8-09

/

M81969/8-10

Protective

600662 600672

/

/

16 18 20

1,23 0,96 0,61

6 5 4

M81969/14-03 (blue / white) M81969/14-04 (yellow / white)

M81969/14-03 (blue / white) M81969/14-04 (yellow / white)

Pilot

16 600660 600894

1,65 2,77

809816 M81969/8-07

809846 M81969/8-08

17-V6 17-E6

Phase Neutral

600661 600671

M22520/1-01 M22520/1-04

12 14

2,98 1,94

8 7

12

2,46 3,61

/

M81969/8-09

/

M81969/8-10

Protective

600662 600672

/

/

16 18 20

1,23 0,96 0,61

6 5 4

M81969/14-03 (blue / white)

M81969/14-03 (blue / white)

Pilot

16 600660 600894

1,65 2,77 M22520/1-01 M22520/1-04

/

/

/

/

21-V4 21-E4

Phase Neutral

809947 + 809908 (hex crimp) or

600663 600673

6

6 13,61 7,3 8,1

/

/

/

/

/

/

809696

809697 (pin) 809690 (socket)

M22520/23-01 + M22520/23-03

Protective

600664 600674

16 18 20

1,23 0,96 0,61

6 5 4

M81969/14-03 (blue / white)

M81969/14-03 blue / white)

Pilot

16 600660 600894

1,65 2,77 M22520/1-01 M22520/1-04

/

/

/

/

23-V4 23-E4

Phase Neutral

612514 612516

4

4 21.2

M22520/23-01 M22520/23-04 /

/

/

/

/

809943

/

Protective

612513 612515

16 18 20

1,23 0,96 0,61

6 5 4

M81969/14-03 (blue / white)

M81969/14-03 (blue / white)

Pilot

16 600660 600894

1,65 2,77 M22520/1-01 M22520/1-04

/

/

/

/

25-V6 25-E6

Phase Neutral

809947 + 809908 (hex crimp) or

600663 600673

6

6 13,61 7,3 8,1

/

/

/

/

/

/

809696

809697 (pin) 809690 (socket)

M22520/23-01 + M22520/23-03

Protective

600664 600674

CRIMPING TOOLS

HYDRAULIC PLIERS 809947

PNEUMATIC PLIERS M22520/23-01

MANUAL CRIMPING PLIERS M22520/1-01

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

18

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - WIRE STRIP LENGTH

A

Layout example 17-V6 / 17-E6

1 Conductor L (L1, L2 & L3) 2 Conductor N 3 Pilot conductor P 4 Protective conductor

A

A

A3 (for shielding braid)

Size

Contact type

A1

A2

P rotective contact

13

Phase contacts (N, L1, L2 & L3) Pilot contact (P)

53 - 63

6 - 6.5

P rotective contact

15

Phase contacts (N, L1, L2 & L3) Pilot contact (P)

53 - 63

6 - 6.5

P rotective contact

17

Phase contacts (N, L1, L2 & L3) Pilot contact (P)

53 - 63

6 - 6.5

42 MAX

P rotective contact

55 - 65

14 - 15.5

21

Phase contacts (N, L1, L2 & L3) Pilot contact (P)

60 - 70

6 - 6.5

P rotective contact

55 - 65

14 - 15.5

23

Phase contacts (N, L1, L2 & L3) Pilot contact (P)

60 - 70

6 - 6.5

P rotective contact

55 - 65

14 - 15.5

25

Phase contacts (N, L1, L2 & L3) Pilot contact (P)

60 - 70

6 - 6.5

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

19

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - VG96944 QUALIFIED CABLES

Size 13

PN

Raw material

WIRE AWG16 white WIRE AWG14 white WIRE AWG14 blue

VG95218T020A003 M81044/12-14-9 M81044/12-14-6 M81044/12-14-45

Tinned copper, jacket PVF modified

Tinned copper, jacket PVDF Tinned copper, jacket PVDF Tinned copper, jacket PVDF

WIRE AWG14 green yellow

Fillers Braid

-

PTFE

TB13-T-63

Tinned copper

Heatshrink

DR25 3/8-0M (VG95343 Part 5 Type D)

Elastomer

Size 15

PN

Raw material

WIRE AWG16 white WIRE AWG12 white WIRE AWG12 blue

VG95218T020A003 VG95218T020A017 M81044/12-12-6 M81044/12-12-45

Tinned copper, jacket PVF modified Tinned copper, jacket PVF modified

Tinned copper, jacket PVDF Tinned copper, jacket PVDF

WIRE AWG12 green yellow

Fillers Braid

-

PTFE

TB13-T-695

Tinned copper

Heatshrink

DR25 1/2-0M (VG95343 Part 5 Type D)

Elastomer

Size 17

PN

Raw material

WIRE AWG16 white WIRE AWG12 white WIRE AWG12 blue

VG95218T020A003 VG95218T020A017 M81044/12-12-6 M81044/12-12-45

Tinned copper, jacket PVF modified Tinned copper, jacket PVF modified

Tinned copper, jacket PVDF Tinned copper, jacket PVDF

WIRE AWG12 green yellow

Fillers Braid

-

PTFE

TB13-T-695

Tinned copper

Heatshrink

DR25 1/2-0M (VG95343 Part 5 Type D)

Elastomer

Size 21

PN

Raw material

WIRE AWG16 white WIRE AWG6 white WIRE AWG6 blue

VG95218T020A003 M22759/16 6-9 M22759/16 6-6 M22759/16 6-4/5

Tinned copper, jacket PVF modified

Tinned copper, jacket PVDF Tinned copper, jacket PVDF Tinned copper, jacket PVDF

WIRE AWG6 green yellow

Fillers Braid

-

PTFE

TB13-T-200

TINNED copper

Heatshrink

DR25 1-0M (VG95343 Part 5 Type D)

Elastomer

Size 23

PN

Raw material

WIRE AWG16 white WIRE AWG4 white WIRE AWG4 blue

VG95218T020A003

Tinned copper, jacket PVF modified

M22759/34 4 M22759/34 4 M22759/34 4

Tinned copper, jacket ETFE Tinned copper, jacket ETFE Tinned copper, jacket PVDF

WIRE AWG4 green yellow

Fillers Braid

-

PTFE

TB13-T-200

Tinned copper

Heatshrink

DR25 1-0M (VG95343 Part 5 Type D)

Elastomer

Size 25

PN

Raw material

WIRE AWG16 white WIRE AWG6 white WIRE AWG6 blue

VG95218T020A003 M22759/16 6-9 M22759/16 6-6 M22759/16 6-4/5

Tinned copper, jacket PVF modified

Tinned copper, jacket PVDF Tinned copper, jacket PVDF Tinned copper, jacket PVDF

WIRE AWG6 green yellow

Fillers Braid

-

PTFE

TB13-T-200

Tinned copper

Heatshrink

DR25 1-0M (VG95343 Part 5 Type D)

Elastomer

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

20

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - MIL QUALIFIED CABLES

Size 13

PN

Raw material

WIRE AWG20 WIRE AWG14

M22759/34 20 M22759/34 14

Tinned copper, jacket ETFE Tinned copper, jacket ETFE

Fillers Braid

/

PTFE

4D045558

Nickel copper

Heatshrink

RW200E-1/2-0 or HLR33001270

Fluroelastomeric or Viton

Size 15

PN

Raw material

WIRE AWG16 WIRE AWG12

M22759/34 16 M22759/34 12

Tinned copper, jacket ETFE Tinned copper, jacket ETFE

Fillers Braid

/

PTFE

4D047547

Nickel copper

Heatshrink

RW200E-3/4-0 or HLR33001900

Fluroelastomeric or Viton

Size 17

PN

Raw material

WIRE AWG16 WIRE AWG12

M22759/34 16 M22759/34 12

Tinned copper, jacket ETFE Tinned copper, jacket ETFE

Fillers Braid

/

PTFE

4D047547

Nickel copper

Heatshrink

RW200E-3/4-0 or HLR33001900

Fluroelastomeric or Viton

Size 21

PN

Raw material

WIRE AWG16 WIRE AWG6

M22759/34 16 M22759/34 6

Tinned copper, jacket ETFE Tinned copper, jacket ETFE

Fillers Braid

/

PTFE

4D045591

Nickel copper

Heatshrink

RW200E-1 1/2-0 or HLR33003810

Fluroelastomeric or Viton

Size 23

PN

Raw material

WIRE AWG16 WIRE AWG4

M22759/34 16 M22759/34 4

Tinned copper, jacket ETFE Tinned copper, jacket ETFE

Fillers Braid

/

PTFE

4D045591

Nickel copper

Heatshrink

RW200E-1 1/2-0 or HLR33003810

Fluroelastomeric or Viton

Size 25

PN

Raw material

WIRE AWG16 WIRE AWG6

M22759/34 16 M22759/34 6

Tinned copper, jacket ETFE Tinned copper, jacket ETFE

Fillers Braid

/

PTFE

4D045591

Nickel copper

Heatshrink

RW200E-1 1/2-0 or HLR33003810

Fluroelastomeric or Viton

Note that High performance Nickel plated or Silver plated wires can also be used for harsh environment applications, to withstand higher temperatures.

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

21

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - HOW TO ORDER - PROPRIETARY DESIGNATIONS

1.

2.

3.

4.

5.

6.

7.

Contact arrangement

Series

S hell type

Crimp contacts

Class

Contact gender

Keying

Deviation

TV

P00

R

W

13-E4

P

-

1. Shell type

4. Contact arrangement 1 3-E4

A ssociated materials and platings for E inserts

A ssociated materials and platings for V inserts

S ize 13 – 4 contacts S ize 15 – 4 contacts S ize 17 – 6 contacts Size 21 - 4 contacts Size 23 - 4 contacts

1 5-E4 1 7-E6 21-E4 23-E4

S hell type

Temperature

W, ZN, ZR, TZ, F , K, S, B

0 6

+175°C *

W, ZN, ZR, TZ

S traight plug

S 06

+200° C

F, K, S, B

-

25-E6 S ize 25 – 6 contacts P lease note that standard inserts have a Comparative Tracking Index (CTI) <100V and can withstand a temperature up to 200°C depending on shell material and platings. 1 3-V4 S ize 13 – 4 contacts 1 5-V4 S ize 15 – 4 contacts 1 7-V6 S ize 17 – 6 contacts 21-V4 Size 21 - 4 contacts 23-V4 Size 23 - 4 contacts 25-V6 S ize 25 – 6 contacts P lease note that VG inserts have a Comparative Tracking Index (CTI) between 175 & 400V (Material Group IIIa) and can withstand a temperature up to 150°C.

W, ZN, ZR, TZ, F , K, S, B

P 00

+175°C *

W, ZN, ZR, TZ

S quare flange receptacle

P S00

+200° C

F, K, S, B

-

W, ZN, ZR, TZ, F , K, S, B

07

+175°C *

W, ZN, ZR, TZ

J am nut receptacle

S 07

+200° C

F, K, S, B

-

2. Crimp contacts R

F or Class W, F, K and B platings

Blank F or Class ZN and TZ plating

5. Contact gender P

P in (500 cycles)

S

S ocket (500 cycles)

3. Class: Material & Finish Shell material

Shell fi nish

6. Keying (Blank) (for normal)

W

Olive drab cadmium

A

B

C

D

F

N ickel

ZN ZR TZ

Aluminum

Black zinc nickel

Black zinc nickel without Chromium 6+

7. Deviation Deviation

Tin Zinc

Shell type compatibility

Description

B K S

Marine bronze

-

R educed flange receptacle with a standard nut

Passivated

F 312

07/S07

Stainless steel

Nickel

F or other deviations availability. please consult us

POWERSAFE / VG96944 - HOW TO ORDER - VG96944 DESIGNATIONS

1.

2.

3.

4.

5.

Series

S hell type

C ontact arrangement

Contact gender

Keying

Material and platings

V G96944-04

A

13-V4

P

N

A

1. Shell type A

3. Contact gender P

S quare flange receptacle

P in (500 cycles)

Receptacle

B C

S

J am nut receptacle

S ocket (500 cycles)

Straight plug

4. Keying N (for normal)

2. Contact arrangement 1 3-V4

A

B

C

D

S ize 13 – 4 contacts

1 5-V4 1 7-V6 21-V4 23-V4

S ize 15 – 4 contacts (qualification to come)

5. Material and platings Shell material

S ize 17 – 6 contacts

Shell fi nish

Size 21 - 4 contacts (qualification to come) Size 23 - 4 contacts (qualification to come)

Olive drab cadmium (13-V4/17-V6/25-V6 only)

A

Aluminum

25-V6 S ize 25 – 6 contacts P lease note that VG inserts have a Comparative Tracking Index (CTI) between 175 & 400V (Material Group IIIa) and can withstand a temperature up to 150°C.

J

Tin Zinc (Qualification in progress)

B

-

Marine bronze

: RoHS compliant

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

22

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - HOW TO ORDER - TV35 BACKSHELLS

1.

2.

3.

4.

5.

6.

C abling chamber length

Series

Backshell style

Backshell size

R ear side diameter

Material and platings

Deviation

TV

35

11

10

11

014

-

1. Backshell style 35

4. Rear side diameter

Aluminum straight band backshell accepting heatshrink moulded piece M arine bronze straight band backshell accepting heatshrink moulded piece

P lease refer to Page 15 0 6 08 1 0

1 2

14 16

20 2 4

28 32 3 6

B35

5. Material and platings Shell material

Shell fi nish

2. Backshell size (same as connector size)

014 023 076

Olive drab cadmium

13

15

17

21

23

25

N ickel

Aluminum

Tin Zinc

3. Cabling chamber length P lease refer to Page 15 10

033K Blank

Black zinc nickel

Marine Bronze

-

6. Deviation F479

Mandatory fo Tin Zinc plated backshells in addition to TZ

POWERSAFE / VG96944 - HOW TO ORDER - TV NSA DESIGNATIONS

1.

2.

3.

Series

Backshell style

Backshell size

Material and platings

TV

NSA

13

014

3. Material and platings Shell material

1. Backshell style NSA

Shell fi nish

S creened clamping braid backshell accepting heatshrink moulded piece

014 023

Olive drab cadmium

Aluminum

N ickel

033K

Black zinc nickel

2. Backshell size (same as connector size)

13

15

17

21

23

25

: RoHS compliant

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

23

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - HOW TO ORDER - PROTECTIVE CAPS

1.

2.

3.

4.

5.

6.

Material and platings

C ap type

C ap style

W ire type

Series

Cap size

Deviation

B

EC

N

TV

W

15

-

1. Cap style EC

4. Material and platings Shell material

F or Square flange receptacle

Shell fi nish

ER

F or Jam nut receptacle

W

Olive drab cadmium

F

F or Plug

F

N ickel

Aluminum

ZN TZ

Black zinc nickel

Tin Zinc * see deviation F479 below

B

Marine Bronze

-

2. Wire type -

Metal chain N ylon cord

N R

5. Cap size (same as connector size) 13 15 17 21

J acketed stainless steel rope

23

25

RO

Ja cketed stainless steel rope with washer end (for plugs)

6. Deviation F579

3. Series TV

F or Reduced flange Jam nut receptacle

F or Power Safe

F479

Mandatory fo Tin Zinc plated Caps in addition to TZ

POWERSAFE / VG96944 - HOW TO ORDER - DUMMY RECEPTACLES

1.

2.

3.

4.

D ummy receptacle

Style

Series

Material and platings

Shell size

SE

00

TVE

W

13

2. Series TVE 1. Style 00

4. Shell size 13

S quare flange

15

17

21

23

25

F or Power Safe

3. Material and platings Shell material

Shell fi nish

W

Olive drab cadmium

F

N ickel

Aluminum

ZN TZ

Black zinc nickel

Tin Zinc

B

Marine bronze

-

: RoHS compliant

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

24

Amphenol Socapex │ POWERSAFE

notes

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

25

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28

Made with FlippingBook - professional solution for displaying marketing and sales documents online