Amtech ADT Dust Collector Series User Manual

11.2 Maintenance Schedule

11.2.1 Daily I nspection

11.2.1.1 Che ck exhaus t fo r visible d ust, r efe r to t roubleshooting. 11.2.1.2 Che ck compressed a i r system for air leakage (lo w p ressure) ; re p air as

necessary.

11.2.1.3 Empty d us t drawers.

11.2.2 Weekly I nspection

11.2.2.1 Inspe ct spar k baffles. Cle an if n ecessary.

11.2.3 Monthly I nspection

11.2.3.1 Che ck filte r cartridges for leaks a nd p rope r fastening; r ep air o r replace a s

necessary.

11.2.3.2 Open t he air t an k drain cock located u nde r the air t an k to exp e l a ny

condensation.

11.2.3.3 Che ck the co mpressed air lin e r egulator, d ryer, a nd filter for prope r operation .

(by o thers)

11.2.4 Three M onths

11.2.4.1 Che ck the fil te r cartridges. 11.2.4.2 Che ck all ele ctrical apparatus for prope r operation. 11.2.4.3 Che ck discharge air c ondition for s igns o f d ust.