EZ-TorQ III Product Operation Manual

The Mountz EZ-TorQ III torque analyzer makes torque testing easy and mobile from calibration labs to assembly stations. Regular tool calibration and torque testing processes help manufacturers ensure repeatable accuracy and adherence to international standards. Companies must control torque to ensure their product’s quality, safety, and reliability aren’t compromised. A torque analyzer is a vital instrument for a quality control program. Investing in a torque testing solution eliminates downtime and expenses for shipping tools back and forth to an outside service center. It allows you to calibrate instruments more often and reduce calibration turnaround times and costs.

EZ-TORQ III TORQUE ANAL OPERATING INSTRUCTIO Rev 3.0 (7/1/2025) OPERATING INSTRUCTIONS

TORQ III TORQUE ANALYZER

SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292

| Phone: (408) 292-2214 | Fax: (408) 292-2733 | mountztorque.com

EZ-TorQ III Manual

EZ-TorQ

orQ III Manual Version 3 (7/1/2025) Manual

Table of Contents 1

Product

3 3 3 4 4 4 5 7 9 9

1.1.

Models

1.2.

Specifications

1.3.

Care and Battery Life and Maintenance and Battery Life and Maintenance

1.4.

Layout

1.5.

Dimensions

1.6.

Run Down Adapters

2

Quick Menu Structure

3

Operation

3.1.

Basic View

3.2.

Advanced View

10 11 12 13 13 14 15 16 17 19 21 22 24 25 26 28 30 31

4

Graph

5

History

6

Set Up

6.1.

Setting

6.2.

System

7

About

8

Calibration mode

9

Data Download: Real Time - HyperTerminal HyperTerminal

10

Data Download: using Excel data streamer

11

SD Memory Card Usage

11.1.

Formatting SD card on your PC

11.2.

Formatting SD card on EZ-TorQ III

11.3.

Reading SD Memory Card Data

12

How to set up RS-232 Port

12.1.

Checking Data Output Through RS-

-232 Port

13

How to update EZ-TorQ III Firmware Calibration and Repairs ware

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

1. Product 1.1. Torque Analyzer Models

Torque Ranges

Torque Rang Torque Ranges

Models

lbf.in

S.I.

Models

lbf.in

S.I. 56.5 - 565 cN.m 113 - 1130 cN.m 169.5 - 1695 cN.m 339 - 3390 cN.m

EZ-TorQ III 1i

0.1 - 1 lbf.in

1.1 -11.3 cN.m 11.3 cN.m

EZ-TorQ III 50i

5 - 50 lbf.in

EZ-TorQ III 3i

0.3 - 3 lbf.in

3.4- 33.9 cN.m 33.9 cN.m

EZ-TorQ III 100i

10 - 100 lbf.in

EZ-TorQ III 5i

0.5 - 5 lbf.in

5.6 - 56.5 cN.m 56.5 cN.m

EZ-TorQ III 150i

15 - 150 lbf.in 169.5

EZ-TorQ III 10i

1 - 10 lbf.in

11.3 - 113 cN.m 113 cN.m

EZ-TorQ III 300i

30 - 300 lbf.in

1.2. Specifications

No.

Feature

Specification

1

Power

DC3.7V 5,000mAh Li-ion rechargeable battery

2

Battery charger

DC5V 2A with USB B - Mini USB pin cable

LCD brightness and power consumption 100% = 600mA ( 6 hours )

Power Consumption & Battery Run Time

3

75% = 500mA ( 8 hours ) 50% = 450mA ( 9 hours ) 25% = 330mA ( 11 hours )

4

LCD display

5” Color LCD Touch Screen (800x480px)

5

Battery Charging Time

6 hours for full charging

Accuracy ± 0.5% of reading from 20% to 100% Accuracy ± 1% of reading from 10% to 20%

6

Accuracy

7

Low Pass Filter Selections

180 / 500 / 1000 Hz

8

Operation Modes

Track, Peak, First Peak

9

Torque Units

ozf.in. / lbf.in / lbf.ft / vN.m / N.m / kgf.m / kgf.cm

10

Data Memory

Memory SD Card, 8GB

11

Multi Language

English, Spanish, French, German, Chinese & Portuguese ch, German, Chinese & Portuguese

12

Test Data Statistics:

SPC data and CMK

13

Torque Reading History

10 last readings

14

Display Reset

Manual or Auto clear

Illuminate when high or low setting is achieved within tolerance setting from target torque setting tolerance

15

Go / No Go LEDs

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

1.3. Care - Make sure you always use the original USB 2A charging cable that came with Tester. - Turn OFF Tester before connecting or disconnecting USB Cable. - For safety purposes, please make sure tester is mounted on surface before usi Make sure you always use the original USB 2A charging cable that came with Tester. Turn OFF Tester before connecting or disconnecting USB Cable. For safety purposes, please make sure tester is mounted on surface before using it. ng it.

1.4. Layout

SD Card

RS-232 port

USB port

- 8Mb SD card for test data saving with auto folder creating of Year, Month - Mini USB port is used for battery charging and data download - RS-232 port for data download - Mounting bolts (two built in M8 bolts) 8Mb SD card for test data saving with auto folder creating of Year, Month Mini USB port is used for battery charging and data download data download (Available as of October 2025) in M8 bolts) - tighten to 45 lbf.in

MB-1 Mounting Bracket Item # 062109

1.5. Dimensions

Battery Life and Maintenance

The torque analyzer uses Li follow standard Li-ion battery usage and maintenance guidelines.

uses Li-Ion batteries, which ion battery usage and

1. Avoid full discharging or full charging. We recommend using and charging the battery within the 20% to 80% range. Avoid full discharging or full charging. We d using and charging the battery within

2. For long-term storage, it is best to keep the battery at approximately 50% charged. term storage, it is best to keep the

3. Typical charge-discharge cycle lifespan is approximately 500 to 1000 discharge cycle lifespan is approximately 500 to 1000 cycles.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

1.6. Run Down Adapters Supplied with EZ

Run Down Adapters Supplied with EZ-TorQ III

EZ-TorQ III

1i

3i

5i

10i

50i

100i

150i

300i

M2 M3

M3 M4

M4 M6

M4 M8

M8 M12

Screw RDA

M2Q

M2Q

M3Q

S-Series RDA

-

RDA-S0

RDA-S1.5

-

-

-

-

-

M2Q

M3Q

M2

M6

M3

M4

M8

M12

Screw run adapters Designed to provide run down simulation for a "hard joint"

for a "hard joint" application.

Input Drive

Output Drive

Models

Item #

American

S.I.

Screw RDA–M2Q

070837

0.3 - 3 lbf.in 3 lbf.in

3.4- 33.9 cN.m

1.5mm Hex

1/4" M/Sq 1/4" M/Sq

Screw RDA–M3Q

070838

0.5 - 5 lbf.in 5 lbf.in

5.6 - 56.5 cN.m

2.5mm Hex

Screw RDA–M2

070820

1 - 4 lbf.in 4 lbf.in

11.3 - 45.2 cN.m

1.5mm Hex

17mm M/Hex 17mm M/Hex 17mm M/Hex 17mm M/Hex 17mm M/Hex 17mm M/Hex

Screw RDA–M3

070821

4 - 10 lbf.in 10 lbf.in

45.2 - 113 cN.m

2.5mm Hex

Screw RDA–M4

070822

10 - 50 lbf.in 50 lbf.in

113 - 565 cN.m

3mm Hex

Screw RDA–M6

070823

10 - 100 lbf.in 100 lbf.in

113 - 1130 cN.m

5mm Hex

Screw RDA–M8

070824

15 - 150 lbf.in 150 lbf.in

169.5 - 1695 cN.m

6mm Hex

Screw RDA–M12

070825

30 - 300 lbf.in 300 lbf.in

339 - 3390 cN.m

10mm Hex

S-Series run down adapters It is designed to provide run down simulation for a It is designed to provide run down simulation for a "soft joint" application.

S0

S1.5

Input Drive

Output Drive

Models

Item #

American

S.I.

RDA-S0

070844

0.3 - 3 lbf.in 3 lbf.in

3.4- 33.9 cN.m

1.5mm Hex

1/4 M/Sq 1/4 M/Sq

RDA-S1.5

070845

0.5 - 5 lbf.in 5 lbf.in

5.6 - 56.5 cN.m

2.5mm Hex

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

A run down adapter is required when testing power tools with the EZ These are joint simulators that provide consistent and reliable torque readings for use with power-driven torque control tools. A run down and irregular peaks that cause poor repeatability. testing power tools with the EZ-TorQ III. driven torque control tools. A run down adapter reduce the impact

Operating Run Down Adapter for EZ  The run down adapter is mounted in-line between the tool drive and the transducer of the EZ-TorQ. Operating Run Down Adapter for EZ-TorQ III (1i - 5i models) line between the tool drive and the

 The run-down adapter must be mounted securely before operating, as it is critical to ensure the accuracy of torque measurements during operation. Tighten the three 1.5mm hex screws EZ down adapter. apter must be mounted securely before operating, as it is Tighten the three 1.5mm hex screws EZ-TorQ's 1/4" drive to secure the run

 The run down adapter is designed to operate in a clockwise direction only. Before each test, the run down adapter should be completely backed operate in a clockwise direction only. Before each test, the run down adapter should be completely backed-up.

Tighten the three 1.5 mm hex screws

 Apply torque until RDA is run down entirely. Then, save the torque reading with the analyzer.

Operating Run Down Adapter for EZ  The run down adapter is mounted in-line between the tool drive and the transducer of the EZ-TorQ. Operating Run Down Adapter for EZ-TorQ III (10i - 300i models) line between the tool drive and the

Insert the run-down adapter into the EZ-

-TorQ's 17mm hex drive.

 The run down adapter is designed to operate in a clockwise direction only. Before each test, the run down adapter should be completely backed Before each test, the run down adapter should be completely backed-up.

 Apply torque until RDA is run down entirely. Then, save the torque reading with the analyzer.

Insert run down adapter in 17mm hex drive

Warning: EZ-TorQ III is not for use in testing Impact or Pulse type tools. ot for use in testing Impact or Pulse type tools.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

2. Quick Menu Structure

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

3. Operation 3.1. Basic View

No Item

Description

1 Parameters

Quick view of test Quick view of test parameters

2 Rotation Direction

Counterclockwise (

 ) Clockwise (  ) Both Directions(  )

Final peak(only First- Peak mode)

3

Final torque value

rque value while in the First-Peak mode.

4 Torque Reading

Peak torque, Track torque or First Peak torque, Track torque or First-peak torque while in each mode

5 Torque units

ozf.in. / lbf.in /

lbf.ft / vN.m / N.m / kgf.m / kgf.cm

6 Manual reset

Clear the display by touching the circle a Clear the display by touching the circle area of no.6

Number of times torque was applied After setting the target torque it displays the number of OK (green) After setting the target torque it displays the number of OK (green) & NG (Red). & NG (Red).

7 Count

8 Switch to Advanced View Display switches to advanced

Display switches to advanced view when pressed

9 Reset All

Reset the number of counts, hist Reset the number of counts, history and all statistic data(Average, Std. Dev, CM, CMK) Dev, CM, CMK)

10 Battery Level Indicator

Battery level percentage

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

3.2. Advanced View

No

Item

Description

1

Parameters

Quick view of test parameters Quick view of test parameters.

2

Rotation Direction

Counterclockwise (

 ) Clockwise (  ) Both Directions (  )

Final peak (only First- Peak)

3

Final torque value while in the First Final torque value while in the First-Peak mode.

4

Torque Reading

Peak torque, Track torque or First Peak torque, Track torque or First-peak torque while in each mode

5

Torque units

ozf.in. / lbf.in / ozf.in. / lbf.in / lbf.ft / vN.m / N.m / kgf.m / kgf.cm

6

Manual reset

Reset the display by touching the circle area of no.6

Number of times torque was applied After setting the target torque it displays the number of OK (green) & NG (Red).

7

Count

8

Statistics

Statistic data display (Std. Statistic data display (Std. Dev, CM, CMK…)

9

Switch to basic view

Display switches to basic view when pressed

10

Reset All

Reset the number of count, history and all statistic data(Average, Std. Reset the number of count, history and all statistic data(Average, Std. Dev, CM, CMK)

11

Battery Level Indicator

Battery level percentage

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

4. Graph

No

Item

Description

1

Torque

Peak torque, Track torque or First Peak torque, Track torque or First-peak torque at each mode

Final peak (only First-Peak)

2

Final torque value on the First Final torque value on the First-Peak mode.

3

Parameters

Parameters on the advanced view operation.

OK zone can be created by the ON/OFF switch when there is a target torque set. The target torque setting is the red line. The Min/Max tolerance from the target will create the green zone on the graph e created by the ON/OFF switch when there is a target torque set. axis shows the max torque, The max torque applied is refreshed by real-time monitoring. X,Y scale is automatically rescaled time monitoring. X,Y scale is automatically rescaled

4

OK Zone

Y-axis shows the max torque, The max torque a by the collected data.

5

Y-axis max torque

X-axis shows the time in ms (milli Sampling rate is 1ms.200 total data points can be captured without data compression. A total of 5,000 data points ( 5 seconds) can be compressed and displayed axis shows the time in ms (milli-second). total of 5,000 data points ( 5 seconds) can be compressed and displayed

6

X-axis time (ms)

7

Manual reset

Clear the display by touching the circle area

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

5. History

No

Description

1

The last 10 data points are saved and refreshed are saved and refreshed.

2

Test result are displayed in Green for OK

Green for OK and Red for NG.

3

If there is not a target torque set OK/NG

target torque set OK/NG, Target, and Tolerance data columns are not used.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

6. Set Up

6.1. Setting

No

Item

Description

Target torque can be selected by the UP target Target torque can be selected by the UP and DOWN arrow. Touch the target torque to open the numeric key pad.

and DOWN arrow. Touch the center of

1

Up/Down &Numeric key pad

2

Target Torque & Tolerance

Check Check on/off to apply the target torque and tolerance settings s.

Select manually clear data

Select amount of time (seconds) to clear the test data display

) to clear the test data displayed. Or disable to

3

Auto clear (sec)

4

Torque Units

ozf.in. / lbf.in / ozf.in. / lbf.in / lbf.ft / vN.m / N.m / kgf.m / kgf.cm

5

Mode

Peak torque, Track torque or First Peak torque, Track torque or First-peak torque

6

LPF (Low Pass Filter) freq

LPF (Low Pass Filter) LPF (Low Pass Filter) frequency setting. ISO standard is 500Hz ISO standard is 500Hz

7

Direction

Rotation direction Rotation direction selection Clockwise, Counterclockwise or Both direction Both directions

You can enter the serial number of the tool you want to measure. This serial number is stored on the SD card along with the This serial number is stored on the SD card along with the test test data

8

Tool SN

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

6.2. System

No

Item

Description

1

Brightness

LCD brightness LCD brightness adjustment

Timer turns off up. (1,3 and 5 mins)

LCD display when not being used. When the LCD screen is touched unit will wake When the LCD screen is touched unit will wake

2

Sleep mode

3

Language

Language selection (English, Spanish, French, Germany, Chin Language selection (English, Spanish, French, Germany, Chinese, Portuguese ese, Portuguese)

. Turn off/disable by unchecking circle. Password is 5809

4

Calibration notice

Calibration expired/reminder notice

expired/reminder notice. Turn off/disable by unchecking circle

System clock adjustment System clock adjustment. Password is 5809 setting Buzzer On/Off setting

5

System time

6

Buzzer

SD card information a If the SD card has Formatting needs to be performed prior to storing any data on SD card card information and format option card has not been formatted toFAT32, it displays “Unknown file system”. “Unknown file system”.

7

SD format

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

7. About

No

Item

Description

1

Model

Torque tester model information

2

Serial number

Product serial no. Product serial no. YY,MM,0000 (2 digits for year, 2 digits for month, 4 digits for se 0000 (2 digits for year, 2 digits for month, 4 digits for sequence)

3

SW version

Software version

4

SD status& usage

SD card information card information (total, used and available memory).

Tap 5 times on the EZ Calibration password is Tap 5 times on the EZ-TORQ III area to enter into the calibration mode. assword is “5809”.

5

Calibration mode

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

8. Calibration Mode

No

Item

Description

1

Max torque

Max torque of the range

2

Serial number

Serial no. YY,MM,

YY,MM,0000 (2 digits for year, 2 digits for month, 4 digits for se

0000 (2 digits for year, 2 digits for month, 4 digits for sequence)

3

Unit

Unit of measure

of measure for calibration mode.

4

Type

Select the amount

amount calibration data points (3 points or 5 points).

5

ADC Value

In order to save

save the AD/calibration value, press and hold the test point field

field for 2 seconds.

6

Save

When pressed When pressed all input calibration data will be saved, unit will automatically exit calibration mode all input calibration data will be saved, unit will automatically exit calibration mode

7

Quit

Finish the Calibration mode

Calibration mode without saving data.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

9. Data Download: Real Time

- HyperTerminal

A. Connect the PC and EZ-TorQ III with a USB cable. B. Make sure “USB Serial Port” is recognized in windows device manager. *The COM port number may differ depending on the with a USB cable. Serial Port” is recognized in windows device manager. *The COM port number may differ depending on the user environment.

C. Run a terminal emulator program on your PC. There are various terminal programs. (e.g. Windows HyperTerminal, Putty, TeraTerm …) Run a terminal emulator program on your PC.

Here is the manual for TeraTerm. - Download link : https://osdn.net/projects/ttssh2/releases/ https://osdn.net/projects/ttssh2/releases/

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

D. In menu, select [File] → [New connection]. When the following screen appears, select Serial and COM → [New connection]. When the following screen appears, select Serial and COM port.

E. The test result is displayed as shown below

is displayed as shown below right after torque testing.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

10. Data Download: using Excel data streamer

Note: Data Streamer add-in is available only for Microsoft Office 365 users. A. Click on “File” menu and select Options. available only for Microsoft Office 365 users. Click on “File” menu and select Options.

B. Select the “Add-ins”, then Select the “COM Add

n Select the “COM Add-ins”, then Press the “Go” button.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

C. Check “Microsoft Data Streamer for Excel” item and Check “Microsoft Data Streamer for Excel” item and click OK.

D. On your Excel application, a new column called “Data Stre E. On the left side of the screen, click on “connect to device”. Than click on “Start Data” On your Excel application, a new column called “Data Streamer” will show up. Click on “Data St On the left side of the screen, click on “connect to device”. Than click on “Start Data”

mer” will show up. Click on “Data Streamer” Menu

F. Go down on the screen and click on “settings” tab. Change to the following settings: lick on “settings” tab. Change to the following settings:

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

G. Go down on the screen and click on “data in” tab to see torque data readings been loaded on the page. It should look like this: Go down on the screen and click on “data in” tab to see torque data readings been loaded on the page. It should

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

11. SD Memory Card Usage SD Memory Card can be formatted two ways: From PC or from EZ SD Memory Card can be formatted two ways: From PC or from EZ-TorQ-III Tester.

11.1. Formatting SD card on your PC ormatting SD card on your PC

A. Insert the SD card into your computer. B. Open windows explorer. C. Find the drive letter for your SD card. D. Right-click, and when the menu appears Insert the SD card into your computer. Find the drive letter for your SD card.

click, and when the menu appears click Format.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

E. In the Format window, file system should be set to FAT32. F. Check “Quick Format”. G. Click Start. In the Format window, file system should be set to FAT32.

H. When the warning appears, select OK. When the warning appears, select OK.

I. Once the formatting is complete, you can close the window. Now you can use the SD card in EZ Once the formatting is complete, you can close the window. Now you can use the SD card in EZ-TorQ-III.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

11.2. Formatting SD card on EZ

Formatting SD card on EZ-TorQ III

A. Insert the SD Card into EZ-TorQ-III. B. Go to [Set Up] → [System.2] screen. C. Select the “Format” button. III. → [System.2] screen.

D. When the warning appears, select OK. When the warning appears, select OK.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

E. Please wait for the format to complete. Please wait for the format to complete.

F. Now you can use the SD card in EZ Now you can use the SD card in EZ-TorQ-III.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

11.3.

Reading SD Memory Card Data Memory Card Data

A. Insert the SD Card into Your Computer. B. Open Windows Explorer. C. Enter the SD card drive. D. Folders are created in order of year E. The file is generated in yyyymmdd.csv format. (y: year, m: month, d: day) he SD Card into Your Computer. Folders are created in order of year→month. The file is generated in yyyymmdd.csv format. (y: year, m: month, d: day)

F. You can view the data using excel or a text editor. You can view the data using excel or a text editor.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

12. How to set up RS-232 Port

232 Port ( Available as of October 2025)

To enable RS-232 communication with the EZ Please follow the steps below.

32 communication with the EZ-TorQ III, configuration of the RS-232 port is required. 232 port is required.

A. Enter the About Tab B. Tap 5 times on the EZ-TorQ III area Enter the password 5809

(marked with red box) to enter into Calibration mode.

C. Tap Module button

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

D. Select RS-232 and tap OK button

E. Save and Quit F. Reboot the EZ-TorQ III

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

12.1 Checking Data Output Through RS

Checking Data Output Through RS-232 Port

Using Terminal Emulator (Tera Term) A. Connect the PC and EZ-TORQ III with USB to RS B. Make sure USB Serial Port is recognized in windows device manager. Note: The COM port number may differ depending on TORQ III with USB to RS-232 cable Make sure USB Serial Port is recognized in windows device manager. The COM port number may differ depending on the user environment.

C. Run a terminal emulator program on your PC. There are various terminal programs. (e.g. Windows HyperTerminal, Putty, TeraTerm …) Run a terminal emulator program on your PC.

Here is the manual for TeraTerm. Download link : https://osdn.net/projects

https://osdn.net/projects/ttssh2/releases/

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

D. (File) – (New connection) When the following screen appears, select Serial and COM Port.

Note: In the Serial Port settings of the Terminal Program, adjust the speed setting to 115200

E. The test result (torque, unit) is displayed immediately af

is displayed immediately after torque testing, as shown below. ter torque testing, as shown below.

Output form is like the following

Integer 5 digits

Torque Unit

Real number

3 digits

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

RS-232 Cable & Converter Accessories Item # 773069 Cable USB to RS232 Adapter Accessories

Item # 773856 RS232 Cable (DB9 Male x DB9 Female, 2 RS232 Cable (DB9 Male x DB9 Female, 2 meters)

13. How to update EZ-TorQ

orQ III Firmware

A. Insert the SD Card into your computer. B. Open windows explorer. C. Enter the SD card drive. D. Create an “update” folder at the top. E. Copy the firmware file to the update folder. NOTE: Firmware Update will be provided Create an “update” folder at the top. Copy the firmware file to the update folder. NOTE: Firmware Update will be provided by Mountz Inc omputer.

F. Insert the SD Card into EZ-TorQ-III. G. When you turn on the power, the firmware upgrade will proceed automatically. H. When the update is complete, it will boot automatically. III. When you turn on the power, the firmware upgrade will proceed automatically. When the update is complete, it will boot automatically.

Note: - There should be only one firmware file in the update folder - When the update is complete, delete the update folder from the SD card. There should be only one firmware file in the update folder.

Tech Support: (669) 200-4219 www.mountztorque.com

3

EZ-TorQ III Manual

Testing and Servicing Torque tools go out of calibration with use. Calibrating a torque tool is a fine tuning process of bringing the tool back within its tolerance. Regular torqu calibration of a hand screwdriver ensures accuracy, repeatable tool performance, and adherence to international standards. We recommend a general once a year calibration interval. However, the user's organization must determine suitable intervals based performance, application, degree of usage, and management objectives. Mountz Calibration and Repair Services Mountz Inc. features an experienced calibration and repair staff. Our trained technicians can calibrate and repair almost any tool. technicians can calibrate and repair almost any tool. Mountz provides rapid service with quality that you can trust as we offer two state-of-the-art calibration service with quality that you can trust as we offer two state labs and repair facilities that can calibrate up to 20,000 lbf.ft. About Mountz Mountz, The Torque Tool Specialists ® , has been a leader in the torque industry for more than 60 years. Engineered in the Silicon Valley and serving the globe, Mountz focuses on delivering high-quality torque products, services, and solutions to ensure customers can always proceed with confidence. We are committed to forging a safer world through precision and accuracy and by innovating every day. Torque tools go out of calibration with use. Calibrating a torque tool is a fine- tuning process of bringing the tool back within its tolerance. Regular torque organization must determine suitable intervals based upon equipment , has been a leader in the torque tool quality torque products, services, and rging a safer world through precision and accuracy and by

Mountz Service Locations

Eastern Service Center 19051 Underwood Rd. Foley, AL 36535 Phone: (251) 943 Fax: (251) 943 Phone: (251) 943-4125 Fax: (251) 943-4979 Western Service Center 1080 N.11th Street San Jose, CA 95112 Phone: (408) 292 Fax: (408) 292 UK Service Center Pier Cops Milland Lane, Liphook, Hampshire, GU30 7JN, UK Phone: 00 44 1428 741756 Pier Copse Courtyard, Phone: (408) 292-2214 Fax: (408) 292-2733

www.mountztorque.com

The Mountz Advantage Products for Industry Experts by Torque Experts We are torque experts. Our tools offer customization options, allowing you to tailor them to your require We are torque experts. Our tools offer customization options, allowing you to tailor them to your requirements.

Experienced Human, Customer Support We take the time to understand your application needs and make recommendations based on industry experience.

Tools Built to Last Preventing downtime is critical for success. Durability is at the core of what extensive testing to ensure they meet the highest standards. Preventing downtime is critical for success. Durability is at the core of what we do. Our tools are built to last and undergo we do. Our tools are built to last and undergo Mountz Support North America: + 1.408.850.9978 International: + 44.1428.741756 mountztorque.com Mountz offers product implementation support and ad Please contact our applications or customer experience teams for additional support. Mountz offers product implementation support and additional technical support beyond our standard service agreement. ditional technical support beyond our standard service agreement.

Scan for Warranty & Returns Policy

Tech Support: (669) 200-4219 www.mountztorque.com

3

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31

www.mountztorque.com

Made with FlippingBook Annual report maker