Section 6
Recipe Settings
Spray Temperature – Desired booth temperature during spraying operations. Cannot be cooler than outdoor air. Booth Pressure – Negative, Positive, or Balanced Zero. Normally set about zero. Positive = more air coming into the booth than being exhausted - Ensures all air coming into the booth has passed through filters - If set too positive, can cause doors to pop open Negative = more air being exhausted than being brought into the booth - If set too negative, can allow debris to be pulled into the booth through un-filtered openings
Winter/Summer – Determines if the burner should be on or off while in spray mode. If it is hot outside, select summer mode to prevent the burner from turning on. If its cold outside, select winter mode to ignite the burner.
Made with FlippingBook - professional solution for displaying marketing and sales documents online