Air Makeup Unit Technical Training Manual

Section 6

Recipe Settings

Flash Temperature – Desired booth temperature during flash mode. Some coatings require a period of time after being applied to “flash off”. During this time, the temperature is lower than a high heat cure temperature.

Flash Time – Amount of time the coating needs to flash off. See the spec sheet for the coating being used.

Cure 1 Temperature – Desired booth temperature during cure mode 1. See the spec sheet for the coating being used.

Cure 1 Time – Amount of time the coating needs to cure.

Cure 2 Temperature – Desired booth temperature during cure mode 2. See the spec sheet for the coating being used.

Cure 2 Time – Amount of time the coating needs to cure. (Set to zero if cure 2 is not needed)

Cool Temperature – Desired booth temperature after the cure mode has finished. Cool Time – Amount of time the coating needs to cool.

Everything above is 1 recipe. The controller is capable of storing 4 recipes labeled A, B, C, and D