Command Line Interface

ptp <clockinst> time-property [ utc-offset <utc_offset> ] [ valid ] [ leap-59 | leap-61 ] [ time-traceable ] [ freq-traceable ] [ ptptimescale ] [ time-source <time_source> ] ptp <clockinst> uni <idx> [ duration <duration> ] <ip> ptp ext [ output | input | out-in ] [ ext <clockfreq> ] [ vcxo | ltc- freq | synce-dpll | osc | ltc-phase ] ptp ho-spec [ cat1 <cat1> ] [ cat2 <cat2> ] [ cat3 <cat3> ] ptp ref-clock { mhz125 | mhz156p25 | mhz250 }

ptp system-time { get | set } ptp tc-internal [ mode <mode> ] <0-3>: Clock instance [0-3] ext:

Update the 1PPS and External clock output configuration and vcxo frequency rate adjustment option

ho-spec: Set the Holdover specification for G8275 PTP clocks system-time: Enable synchronization between PTP time and system time tc-internal: Define the internal mode used in TC's. Example: Input: 0* (config)# ptp 0 ? Output: Clk Sync: Set PTP slave clock options.

<1-1000>: [1..1000] Threshold in ns for offsetFromMaster defines when the offset increment/decrement mode is entered.

Domain:

Clock domain for PTP. <0-127>: PTP domain: range = 0-127.

Filter:

Set filter parameters: delay:

Set delay filter parameter. <0-6>: Log2 of timeconstant in delay lowpass filter, valid range: 1-6, Setting the value to 0 means use the same filter function as for the offset measurement, in this case the delay filter uses the 'period' and 'dist' parameters. Set offset filter dist parameter. <0-10>: Distance between servo update n number of measurement periods, valid range: 0-10, 0 => 0,1 Hz lowpass filtering, 1 => averaging over period, >1 => 'min' offset filtering.

dist:

filter-type: Define offset filter type: basic: Basic offset filter. ms-pdv: MS-PDV.