MC:
Frame must be multicast
BC:
Frame must be broadcast
UC: Frame must be unicast Specific: Filter a specific destination MAC address with this ACE. A field for entering a DMAC value appears. DMAC Value When “Specific” is selected for the DMAC filter, the user can enter a specific destination MAC address. The legal format is “xx-xx-xx-xx-xx-xx” or “xx.xx.xx.xx.xx.xx” or “xxxxxxxxxxxx” (x is a hexadecimal digit). A frame that hits this ACE matches this DMAC value.
4.23.2.3
VLAN Parameters
802.1Q tagged Set or show 802.1Q Tagged operation status. The status determines whether or not frames can hit the action according to the 802.1Q Tagged: Any: Any value is allowed (“don’t care”) (The default value is “Any”.)
Enabled: Tagged frame only Disabled:Untagged frame only
VLAN ID Filter Set or show the VLAN ID filter for this ACE. Any:
No VLAN ID filter is specified. (VLAN ID filter status is “don’t care”.) Specific: Filter a specific VLAN ID with this ACE. A field for entering a VLAN ID number appears. VLAN ID When “Specific” is selected for the VLAN ID filter, the user can enter a specific VLAN ID number. The allowed range is 1 to 4095. A frame that hits this ACE matches this VLAN ID value. Tag priority Set or show the tag priority for this ACE. A frame that hits this ACE matches this tag priority. The allowed number range is 0 to 7 or range 0-1, 2-3, 4-5, 6-7, 0-3 and 4-7. The value “Any” means that no tag priority is specified (tag priority is “don’t care”.)