RES-SCE-8MG - SMB CLI - User Manual Rev 1.01 - A TERMINER

Switchport Hybrid Egress-Tag Set egress VLAN tagging configuration. Values are: none: no egress tagging all: tag all frames except-native:

tag all frames except frames classified to native VLAN of the hybrid port

Syntax: switchport hybrid egress-tag { none | all [ except-native ] } Switchport Hybrid Ingress-Filtering VLAN ingress filter configuration (enable ingress filtering). Syntax: switchport hybrid ingress-filtering Switchport Hybrid Native VLAN Set native VLAN. Values are: <pvid>: VLAN ID of the native VLAN when this port is in hybrid mode Syntax: switchport hybrid native vlan <pvid>

Switchport Hybrid Port-Type Set the port type. Values are: c-port: customer port s-custom-port: custom provider port s-port: provider port unaware:

port in not aware of VLAN tags

Syntax: switchport hybrid port-type { unaware | c-port | s-port | s-custom- port }

Switchport Mode Set mode of the interface.

access: set mode to ACCESS unconditionally hybrid: set mode to HYBRID unconditionally trunk: set mode to TRUNK unconditionally Syntax: switchport mode { access | trunk | hybrid }

SMB - CLI UM

Rev: 1.1

Page 38 of 275

www.amphenol-socapex.com

Tel : +33(0)4.50.89.28.00

Made with FlippingBook interactive PDF creator